FieldServer Appendix C. Driver Error Messages, FS-8700-103ATMITGMSerial ManualPage 22

Page 22

FS-8700-103_ATMI_TGM_Serial ManualPage 22 of 28

Appendix C. Driver Error Messages

 

Message

 

 

 

Notes and Corrective Action

 

TGM:#1 Err. Diagnostic #1.

If this message is printed an internal diagnostic has been

 

generated. Contact FieldServer tech support for help.

 

 

 

 

 

 

 

TGM:#2 Err. TGM_Function not

Each Map Descriptor must have the parameter called

 

specified.

 

 

 

“TGM_Function” set. See section 4.4.22

 

TGM:#3 FYI. Use an Array

This message may be ignored. For more information read

 

called

<%s>

to

expose

Appendix C.1

 

diagnostics.

 

 

 

 

 

 

 

 

 

 

4a: The text string “CUR=” could not be found in the QLA

 

 

 

 

 

 

report.

 

 

 

 

 

 

4b: The text string “GAS=” could not be found in the QLA

 

 

 

 

 

 

report.

 

 

 

 

 

 

4c: The text string “STATUS=” could not be found in the

 

TGM: #4c Err. Bad format in

QLA report.

 

If the error is printed rarely and data is being stored

 

latest

area

report. Discarding

correctly then the error probably arises from a corrupted

 

data.

 

 

 

 

message. If the error occurs frequently then it is possible

 

 

 

 

 

 

 

 

 

 

 

 

that the report format has changed and the driver firmware

 

 

 

 

 

 

may require an update. To facilitate the evaluation of the

 

 

 

 

 

 

problem, take a serial communications log, ensuring at least

 

 

 

 

 

 

one of the errors occurs during the log, and then contact

 

 

 

 

 

 

Tech Support.

 

 

 

 

 

 

This message is printed to alert you to the fact that the

 

TGM: #5 FYI. atmitgm.ini being

malfunction list is being based on the contents of a TGM

 

used for malfunctions

 

config file. Refer to Appendix B.7. If you expect the driver to

 

 

 

 

 

 

be using this list, ignore the message.

 

TGM: #6 FYI. You could have

This message is printed to alert you to the possibility that

 

used a TGM config file to define

 

malfunctions. Working with hard

the TGM config file can be used with this driver. Refer to

 

coded list.

 

 

 

Appendix B.7.

 

 

 

 

 

 

TGM:

#7

Err.

Driver

cannot

The Map Descriptor function has been set so that the driver

 

write. MD=%s

 

 

will attempt to write to the TGM. Writing is not possible.

 

 

 

Change the function to a read.2

 

TGM:

#8

Err.

Array=%s too

This error is printed when the driver attempts to store data

 

short. Act/Rqd=%d/%d

 

from the QLA report. Modify the length of the Data Array as

 

 

discussed in section 4.1.2

 

TGM: #9 FYI. Duplicate Gas

This message may be safely ignored. It is printed to alert

 

Name=<%s>.

 

 

you to the fact that the driver has updated the Gas Name

 

Value

has

been

updated

 

from=%d to=%d

 

table so that default values have been modified.

 

 

 

2 Modify the configuration CSV file. Download the modified file to the FieldServer and Reset the FieldServer for the changes to take effect.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 22
Contents FS-8700-103 ATMI-TGM Serial Driver Table of Contents FS-8700-103ATMITGMSerial Manual Max Nodes Supported FieldServer Mode CommentsAtmi TGM Serial Driver Description Client Only 1 Server Node Allowed PER PortRequired 3rd Party Configuration FieldServer Technologies DescriptionHardware Connections Malfun Printer OFF Line Hardware Connection Tips / HintsMalfun Remote OFF Line Section Title Configuring the FieldServer as a Atmi TGM Serial ClientData Arrays/Descriptors Column Title Function Legal ValuesClient Side Node Descriptors Client Side Connection DescriptionsNone RDBC, ARS Driver Related Map Descriptor ParametersTiming Parameters Column Function Legal Values TitleMap Descriptor Example #1 Calr Report CalrMap Descriptor Example #2 QLA Report Map Descriptor Example #3 QIR Report Malfunctions QIRCH4 CH4AC CL2 DET Gas Name Index ValueNone ASH3 GEH4 H2AC H2S H2SE HCL N2O NF3 NH3 PH3 Pocl POCL3 SihxAppendix A.2. Malfunction Table Offset Malfunction Return to NormalEngineering Units Index Value Appendix A.3. Gas Concentration Engineering UnitsARU PPM PPB LEL PCT Alarm Reset ALL Malfunctions Clear Data Array specified by the DataArrayName ContentsAppendix B.2. How Gas Data is Stored Data Array specified by the DABitNameAppendix B.4. Adding / Modifying Hard Coded Gas Names PPM TGMDisk Nearly Full TGM Appendix B.5. Adding / Modifying Malfunction StringsC2H5OH TGM Disk is Full TGMDisk no Longer Full TGM Appendix B.6. Adding / Modifying ‘Return to Normal’ StringsDisk not Full TGM Appendix B.8. Synchronizing Malfunctions FS-8700-103ATMITGMSerial ManualPage 22 Appendix C. Driver Error MessagesMessage FS-8700-103ATMITGMSerial Manual Message FYI#21 UINT16 Appendix C.1. Exposing Driver Operating StatisticsStat Relative Offset FS-8700-103ATMITGMSerial Manual Word baudRate = This page Intentionally Left Blank

FS-8700-103 specifications

The FieldServer FS-8700-103 is an advanced gateway solution designed to facilitate seamless communication between different building automation systems and devices. Its primary function is to provide interoperability among various protocols and devices, which is increasingly important in modern facility management. The FS-8700-103 alleviates common challenges faced by system integrators, allowing for easy integration and operation of diverse systems from multiple manufacturers.

One of the standout features of the FieldServer FS-8700-103 is its support for multiple communication protocols. These include Modbus, BACnet, LonWorks, and SNMP, among others. This versatility allows the FS-8700-103 to serve as a bridge between legacy systems and newer technologies, thus extending the useful life of existing infrastructure while enabling the addition of advanced system capabilities.

The FS-8700-103 is equipped with numerous ports, including Ethernet connections, which support both wired and wireless communications. This flexibility ensures that the gateway can fit into various network configurations and adapt to different deployment scenarios. In addition, its robust design guarantees reliable performance even in demanding environments, making it suitable for use in commercial, industrial, and residential applications.

Another key characteristic of the FS-8700-103 is its intuitive web-based interface. This interface simplifies the configuration process, allowing users to set up the system with minimal technical expertise. The built-in diagnostic tools provide real-time monitoring and troubleshooting capabilities, enabling operators to quickly identify and address issues, thus reducing downtime and enhancing operational efficiency.

Security is also a notable feature of the FS-8700-103. With increasing concerns regarding cybersecurity in building management systems, this gateway incorporates advanced security protocols to protect data integrity and privacy. This ensures that sensitive information remains safeguarded against unauthorized access.

In summary, the FieldServer FS-8700-103 stands out as a reliable and versatile solution for achieving interoperability in building automation systems. Its support for multiple protocols, robust connectivity options, user-friendly interface, and strong security measures make it a valuable asset for any organization looking to streamline operations and enhance the effectiveness of their automation systems. With the FS-8700-103, organizations can move towards a more integrated and efficient future in facility management.