FieldServer FS-8700-103 instruction manual Appendix B.8. Synchronizing Malfunctions

Page 21

FS-8700-103_ATMI_TGM_Serial Manual

Page 21 of 28

normal string then you will need to add the matching ‘Return to Normal’ string. This process is described in Appendix B.6

Appendix B.8. Synchronizing Malfunctions

THE Incident Report (QIR) only reports events which occurred since the previous poll.

The following procedure is recommended for synchronizing the FieldServer and the TGM

1.Turn off the FieldServer. Clear all events on the TGM and then restart the FieldServer. Or

2.With the FieldServer online, cause the TGM to send an RESET ALARMS message to the FieldServer.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldserver.com

Image 21
Contents FS-8700-103 ATMI-TGM Serial Driver Table of Contents Atmi TGM Serial Driver Description Max Nodes Supported FieldServer Mode CommentsFS-8700-103ATMITGMSerial Manual Client Only 1 Server Node Allowed PER PortFieldServer Technologies Description Required 3rd Party ConfigurationHardware Connections Hardware Connection Tips / Hints Malfun Printer OFF LineMalfun Remote OFF Line Data Arrays/Descriptors Configuring the FieldServer as a Atmi TGM Serial ClientSection Title Column Title Function Legal ValuesClient Side Connection Descriptions Client Side Node DescriptorsNone Timing Parameters Driver Related Map Descriptor ParametersRDBC, ARS Column Function Legal Values TitleCalr Map Descriptor Example #1 Calr ReportMap Descriptor Example #2 QLA Report QIR Map Descriptor Example #3 QIR Report MalfunctionsNone ASH3 Gas Name Index ValueCH4 CH4AC CL2 DET GEH4 H2AC H2S H2SE HCL N2O NF3 NH3 PH3 Pocl POCL3 SihxOffset Malfunction Return to Normal Appendix A.2. Malfunction TableAppendix A.3. Gas Concentration Engineering Units Engineering Units Index ValueARU PPM PPB LEL PCT Alarm Reset ALL Malfunctions Clear Appendix B.2. How Gas Data is Stored ContentsData Array specified by the DataArrayName Data Array specified by the DABitNamePPM TGM Appendix B.4. Adding / Modifying Hard Coded Gas NamesC2H5OH TGM Appendix B.5. Adding / Modifying Malfunction StringsDisk Nearly Full TGM Disk is Full TGMAppendix B.6. Adding / Modifying ‘Return to Normal’ Strings Disk no Longer Full TGMDisk not Full TGM Appendix B.8. Synchronizing Malfunctions Appendix C. Driver Error Messages FS-8700-103ATMITGMSerial ManualPage 22Message FYI FS-8700-103ATMITGMSerial Manual Message#21 Appendix C.1. Exposing Driver Operating Statistics UINT16Stat Relative Offset FS-8700-103ATMITGMSerial Manual Word baudRate = This page Intentionally Left Blank

FS-8700-103 specifications

The FieldServer FS-8700-103 is an advanced gateway solution designed to facilitate seamless communication between different building automation systems and devices. Its primary function is to provide interoperability among various protocols and devices, which is increasingly important in modern facility management. The FS-8700-103 alleviates common challenges faced by system integrators, allowing for easy integration and operation of diverse systems from multiple manufacturers.

One of the standout features of the FieldServer FS-8700-103 is its support for multiple communication protocols. These include Modbus, BACnet, LonWorks, and SNMP, among others. This versatility allows the FS-8700-103 to serve as a bridge between legacy systems and newer technologies, thus extending the useful life of existing infrastructure while enabling the addition of advanced system capabilities.

The FS-8700-103 is equipped with numerous ports, including Ethernet connections, which support both wired and wireless communications. This flexibility ensures that the gateway can fit into various network configurations and adapt to different deployment scenarios. In addition, its robust design guarantees reliable performance even in demanding environments, making it suitable for use in commercial, industrial, and residential applications.

Another key characteristic of the FS-8700-103 is its intuitive web-based interface. This interface simplifies the configuration process, allowing users to set up the system with minimal technical expertise. The built-in diagnostic tools provide real-time monitoring and troubleshooting capabilities, enabling operators to quickly identify and address issues, thus reducing downtime and enhancing operational efficiency.

Security is also a notable feature of the FS-8700-103. With increasing concerns regarding cybersecurity in building management systems, this gateway incorporates advanced security protocols to protect data integrity and privacy. This ensures that sensitive information remains safeguarded against unauthorized access.

In summary, the FieldServer FS-8700-103 stands out as a reliable and versatile solution for achieving interoperability in building automation systems. Its support for multiple protocols, robust connectivity options, user-friendly interface, and strong security measures make it a valuable asset for any organization looking to streamline operations and enhance the effectiveness of their automation systems. With the FS-8700-103, organizations can move towards a more integrated and efficient future in facility management.