21. Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs for the plasma monitor.
Transmission Data
DFH 80H 60H 70H 02H DATA00 DATA01 CKS
DATA00: | AUDIO INPUT | |
| 01H: | AUDIO 1 |
| 02H: | AUDIO 2 |
| 03H: | AUDIO 3 |
DATA01: | VISUAL INPUT | |
| 01H: | Video 1 |
| 02H: | Video 2 |
| 03H: | Video 3 |
| 05H: | HD (HD1 or DTV or DTV1) |
| 06H: | HD2 (DTV2) |
| 07H: | RGB 1/ PC 1 |
| 08H: | RGB 2/ PC 2 |
| 0CH: | RGB 3/ PC 3 |
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 70H 00H CKS
*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 01 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.
22. Audio Select Request
Function
The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.
Transmission Data
1FH 80H 60H 6FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS
DATA00: | AUDIO 1 |
|
DATA01: | AUDIO 2 |
|
DATA02: | AUDIO 3 |
|
| VISUAL INPUT DATA | |
| 01H: | Video 1 |
| 02H: | Video 2 |
| 03H: | Video 3 |
| 05H: | HD (HD1 or DTV or DTV 1) |
| 06H: | HD2 (DTV2) |
| 07H: | RGB 1 /PC 1 |
| 08H: | RGB 2 /PC 2 |
| 0CH: | RGB 3 /PC 3 |
23. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) of the plasma monitor.
Transmission Data
DFH 80H | 60H 6BH 03H DATA00 DATA01 DATA02 CKS |
DATA00 : PLE |
|
01H: | AUTO |
02H: | LOCK |
DATA01 : INVERSE | |
01H: | ON |
02H: | OFF |
03H: | WHITE |
DATA02 : ORBITER (PICTURE SHIFT) | |
01H: | ON |
02H: | OFF |
ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness):
3FH 60H 80H 6BH 00H CKS
24. Failure Mode Request
Function
The external control equipment inquires the detection of failures of the plasma monitor.
Transmission Data
1FH 80H 60H 3FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0 : PDP MODULE
0:Abnormal
1:Normal
Bit 1 : 1: fixed (backup)
Bit 2 : TEMPERATURE
0:Abnormal
1:Normal
Bit 3 : FAN
0:Abnormal
1:Normal
Bit 4 : 1: fixed (backup)
Bit 5 : 1: fixed (backup)
Bit 6 : 1: fixed (backup)
Bit 7 : 1: fixed (backup)
DATA00:FILURE MODE 2
Bit
46