Note: If you do not press the Feed button within 3 seconds, the printer prints “Dump mode not entered” and resumes normal operation.
3At this point, the printer is in Dump mode and prints the ASCII hex codes of any data sent to it and their text representation (or [.] if not a printable character).
Additionally, a file with a .DMP extension containing the ASCII information is created and stored in the printer’s memory. You can view, clone, or delete the file using the Intermec PLUS application.
To exit Communications Diagnostics mode and return the printer to normal operations
1Turn the printer off.
2Wait 5 seconds.
3Turn the printer on.
Specifications
Printing Specifications
Print density | 8 dots/mm (203 dots/inch) |
Print width | Up to 103.8 mm (4.09 inches) |
|
|
Print speed | 76.2 mm (3 inches) per second |
Printhead life, calculated | 50 km (1,964,160 inches) nominal |
|
|
Distance from print element to | 14.5 mm (0.571 inch) or 116 dots |
top of form |
|
|
|
Memory/Communications Specifications
| Flash memory | 2 MB flash (standard) |
| SRAM memory | 2 MB SRAM (standard) |
|
|
|
| Standard | Configurable baud rate (from 9600 to 115.2 Kbps), |
| communications | parity and data bits. The highest baud rate with |
|
| consistent results is 38.4 Kbps. |
|
| Software (XON/XOFF) or hardware (DTR/STR) |
|
| communication handshake protocols. |
58 |
| EasyCoder PL4 Printer User’s Guide |