Directed Electronics K10 door lock harness H4, wire connection guide, LED, 2-pin WHITE plug, H2/A

Page 7
door lock harness (H4), wire connection guide

door lock harness (H4), wire connection guide

H2/A

___

Green

(-) Lock, (+) Unlock Output

 

 

 

 

___

 

 

H2/B

Empty

Unless Using Resistor Interface

 

 

 

 

___

 

 

H2/C

Blue

(-) Unlock, (+) Lock Output

 

 

 

 

 

 

 

Important! The door lock outputs are low current and should not be attached directly to any high current device; they are only to be used to activate relays

peripheral plug-in harnesses

LED, 2-pin WHITE plug

The LED operates at (+) 2 volt DC and plugs into the two-pin WHITE port. Make sure the LED wires are not shorted to ground as the LED will be damaged. Multiple LED’s can be used, but they must be wired in series. The LED fits into a 9/32-inch mounting hole. Be sure to check for clearance prior to drilling the mounting hole.

NOTE: Never use a BLUE LED in combination with a RED LED.

DIA-41

override switch, 2-pin BLUE plug

The override switch should be accessible from the driver’s seat. It plugs into the BLUE port on the side of the unit. Consider how the button will be used before choosing a mounting location. Check for rear clearance before drilling a 9/32-inch hole and mounting the button.

8

Image 7
Contents Model K10 installation guidepower-up wiring quick reference guide table of contentsdoor lock harness H4, wire connection guide module programming system features menus feature descriptionsH1/1 ORANGE - Ground-When-Armed Output primary harness H1 wire connection guideprimary harness H1 wiring diagram primary harness wire descriptionsH1/3 WHITE/BLUE - Channel 3 Output H1/2 WHITE - Parking Light OutputH1/4 BLACK/WHITE - 200 mA Domelight Supervision Output H1/10 BROWN - Horn Honk Output H1/6 BLUE - 200 mA Second Unlock OutputH1/8 BLACK - Chassis Ground Connection H1/9 YELLOW + Ignition InputH1/12 RED/WHITE channel 2, 200mA - output H1/11 RED +12V constant power inputLED, 2-pin WHITE plug door lock harness H4, wire connection guideoverride switch, 2-pin BLUE plug peripheral plug-in harnessesPro Security Programmer interface, 3-pin port module programmingTo enter the learn routine More than 15 seconds elapses between programming steps 4. Release. The Override switch can now be releasedThe Override switch is pressed too many times The learn routine will be exited if The ignition is turned onfeature descriptions system features menusremote coding Function standard configuration remote configurationssingle button arm/disarm configuration power-up Pro Security Programmer Override Switch 3-Pin 2-Wire Door wiring quick reference guideLock Harness 2003 Directed Electronics, Inc. - All rights reserved GK10 Ungo Pro Security 661 W. Redondo Beach Blvd Gardena, Ca800-GO-CLARION Get Started Get Protected