Dell T620 owner manual Opening The System, Closing The System

Page 43

Opening The System

CAUTION: Installing the feet on a stand-alone tower system is necessary to provide a stable foundation for the system. Failure to install the feet poses the risk of having the system tip over, possibly causing bodily injury or damage to the system.

NOTE: It is recommended that you always use a static mat and static strap while working on components in the interior of the system.

1.Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2.Rotate the latch release lock counter clockwise to the unlocked position.

3.Press down on the cover release latch and rotate the latch end of the cover away from the system.

4.Grasp the cover on both sides, and carefully move the cover away from the system.

Figure 13. Opening and Closing the System

1.system

2.system side cover

3.cover release latch

4.latch release lock

Closing The System

1.Place the bottom edge of the cover, opposite from the cover release latch, into the slots in the system chassis.

2.Lower the cover into the chassis.

3.Press the latch end of the cover into the chassis until the latch locks into place.

4.Turn the cover latch release lock clockwise to the locked position.

43

Image 43
Contents Regulatory Model E17S Series Regulatory Type E17S001 Dell Inc. All Rights Reserved Contents Wheel Assembly Optional-Tower Mode Installing System ComponentsInternal USB Memory Key Optional Removing The Control Panel-Tower Mode Jumpers And Connectors Converting The System From Tower Mode To Rack ModeTroubleshooting Your System Using System DiagnosticsGetting Help About Your System Front-Panel Features And Indicators-Tower ModeIndicator, Button, or Icon Description Connector Drive systems Inch hardFront-Panel Features And Indicators-Rack Mode S110 Software RAID Button Description LCD Panel FeaturesHome Screen Setup MenuView Menu Hard-Drive Indicator Patterns Back-Panel Features and Indicators Back-Panel Features And Indicators1100 W Power Indicator Codes NIC Indicator CodesGreen Link indicator is Other Information You May Need Page Page F11 F12 Choosing The System Boot ModeKeystroke Description F10Responding To Error Messages Entering System SetupUsing The System Setup Navigation Keys System Information Screen System Setup OptionsSystem Setup Main Screen System Bios ScreenProcessor Settings Screen Memory Settings ScreenExecute Disable option is set to Enabled Option is set to EnabledPrefetcher option is set to Enabled Execute DisableBoot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning a System And/Or Setup Password Operating With a Setup Password Enabled Using Your System Password To Secure Your SystemExits the Boot Manager and proceeds with system boot Entering The Uefi Boot ManagerUsing The Boot Manager Navigation Keys Boot Manager ScreenEntering The iDRAC Settings Utility IDRAC Settings UtilityEmbedded System Management Changing The Thermal Settings Page Recommended Tools Installing The Front BezelFront Bezel Optional Removing The Front Bezel System Feet-Tower ModeRemoving The System Feet Removing The Wheel Assembly Wheel Assembly Optional-Tower ModeInstalling The System Feet Installing The Wheel AssemblyOpening And Closing The System Removing and Installing the Wheel AssemblyClosing The System Opening The SystemInside the System Inside The SystemRemoving The Bezel Blank Bezel BlankCooling Shroud Installing The Bezel BlankRemoving The Cooling Shroud System Memory Installing The Cooling ShroudChannel 0 slots A1, A5, and A9 ProcessorDimm Type General Memory Module Installation GuidelinesOperating Frequency in MT/s Maximum Dimm Rank Channel Advanced ECC Lockstep Mode-Specific GuidelinesDimm Size Number Sample Memory Configuration TableDIMMs Frequency B10, B11, B12 B10, B11, B12 Removing Memory ModulesFlex Bays Installing Memory ModulesRemoving a Flex Bay Removing and Installing a Flex BayHard Drives Installing a Flex BayRemoving a 2.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard Drive Installing a 2.5 Inch Hard-Drive BlankInstalling a 3.5 Inch Hard-Drive Blank Removing a 3.5 Inch Hard-Drive BlankRemoving and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Slim Optical Drive Blank Installing a Hard Drive Into a Hard-Drive CarrierRemoving The Slim Optical Drive Blank Optical Drives And Tape Drives Installing The Slim Optical Drive BlankRemoving The Optical Drive Or Tape Drive Removing and Installing the Optical Drive or Tape Drive Cabling-Optical Drive and Tape Drive Cooling Fans Installing The Optical Drive Or Tape DriveRemoving a Cooling Fan Removing The Cooling-Fan Assembly Optional Installing a Cooling FanRemoving and Replacing the Cooling-Fan Assembly Installing The Cooling-Fan Assembly OptionalPCIe Card Holder Internal USB Memory Key OptionalReplacing The Internal USB Key Removing The PCIe Card Holder Installing The PCIe Card HolderRemoving The GPU Card Holder GPU Card Holder OptionalInstalling The GPU Card Holder Expansion Cards Expansion Card Installation GuidelinesCard Priority Card Type Slot Priority Maximum Allowed Priority Maximum Allowed GPU Card Installation GuidelinesRemoving An Expansion Card Card Priority Card TypeRemoving and Installing the Expansion Card Installing An Expansion CardRemoving a GPU Card Removing and Installing the GPU Card Installing a GPU CardInternal Dual SD Module SD vFlash CardReplacing An SD vFlash Card Removing An Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal Dual SD ModuleInstalling An Internal SD Card Internal SD CardRemoving a Processor ProcessorsRemoving and Installing a Processor Socket release lever Installing a Processor Power Supplies Removing An AC Power Supply Hot Spare FeatureRemoving and Installing an AC Power Supply Installing An AC Power SupplyRequired Tools Wiring Instructions For a DC Power SupplyAssembling The DC Input Power Wires Assembling the DC Input Power Wires Removing a DC Power SupplyRemoving and Installing a DC Power Supply Installing a DC Power SupplyRemoving The Power Interposer Board Power Interposer Board And Power Distribution BoardRemoving The Power Supply Blank Installing The Power Supply BlankRemoving and Installing The Power Interposer Board Removing The Power Distribution BoardInstalling The Power Distribution Board Installing The Power Interposer Board System BatteryReplacing The System Battery Hard-Drive Backplane Removing and Installing the System BatteryRemoving The Hard-Drive Backplane Removing and Installing The PCIe SSD Hard-Drive BackplanePower cable Power connector on backplane Power connector SAS a connector on Perc card Power connector on PDB 100 PCIe C cable Cabling-3.5 Inch x8 Plus 2.5 Inch x4 SAS/SATA Backplane SAS B cable Backplane Release pin 103 Cabling-3.5 Inch x12 SAS/SATA Backplane Removing and Installing 2.5 Inch x16 SAS/SATA Backplane Cabling-2.5 Inch x16 SAS/SATA Backplane Signal cable Backplane PCIe a cable 107 PDB SAS a cable Backplane SAS B cable Signal cable 109 SAS a connector on 2nd Perc SAS B cable Backplane SAS A1 cable SAS B1 cable 111 Backplane 2 SAS a connector System Top Cover Installing The Hard-Drive BackplaneRemoving The System Top Cover System Left Side Cover Installing The System Top CoverRemoving The System Left Side Cover Control Panel Installing The System Left Side CoverRemoving and Installing the Control Panel-Tower Mode Removing The Control Panel-Tower ModeRemoving The Control Panel-Rack Mode Installing The Control Panel-Tower ModeControl panel module Screw Removing The Control-Panel Board Installing The Control Panel-Rack ModeLCD Module Installing The Control-Panel BoardRemoving and Installing the LCD Module in the Tower Mode Removing The LCD Module-Tower ModeRemoving The LCD Module-Rack Mode Installing The LCD Module-Tower ModeVGA Module Installing The LCD Module-Rack ModeRemoving The VGA Module Removing and Installing the VGA ModuleSystem Board Installing The VGA ModuleRemoving The System Board Removing the System Board Installing The System BoardPage 128 Safety Instructions Converting The System From Tower Mode To Rack ModeRemoving and Installing the Rack Slide Cover Attaching the Mylar Cover Removing and Installing the System Ears Troubleshooting The Video Subsystem Troubleshooting External ConnectionsTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting Cooling Fans Troubleshooting Cooling ProblemsTroubleshooting System Memory Troubleshooting An SD Card Troubleshooting An Internal USB KeyTroubleshooting An Optical Drive Troubleshooting Expansion Cards Troubleshooting a Hard DriveTroubleshooting Processors 142 When To Use The Embedded System Diagnostics Dell Online Diagnostics Dell Embedded System DiagnosticsRunning The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper System Board Jumper SettingsConnector Description System Board ConnectorsIDRACRJ45 Disabling a Forgotten Password Expansion slots Expansion BusMemory Or Sata hard drives DrivesInternal Connectors BackExpanded Operating Temperature FrontMaximum Vibration Environmental TemperatureTemperature Continuous Operation Relative HumidityOperating Altitude De-rating EnvironmentalMaximum Shock Maximum AltitudeCopper Coupon Corrosion Rate Removing LCD Messages System Error MessagesLCD Messages Viewing LCD MessagesAction Error CodeAMP0302 Message DetailsCPU0000 Message ASR0003 MessageBAT0002 Message BAT0017 MessageCPU0700 Message CPU0010 MessageCPU0023 Message CPU0204 MessageCPU0703 Message Exception is external to the processorCPU0704 Message Details Fan operating speed is out of range Action If the issue persists, see Getting HelpAction Reinstall or reconnect the hardware HWC2003 Message FAN0000 MessageMEM0701 Message MEM0000 MessageMEM0001 Message MEM0007 MessagePCI1304 Message MEM1208 MessageMEM8000 Message PCI1302 MessagePCI1360 Message PCI1320 MessagePCI1342 Message PCI1348 MessagePSU0002 Message PST0128 MessagePST0129 Message PSU0001 MessagePSU0032 Message PSU0006 MessagePSU0016 Message PSU0031 MessagePSU0037 Message PSU0034 MessagePSU0035 Message PSU0036 MessageSystem power consumption PSU1201 Message Power supply redundancy is lost DetailsSystem power inventory change Configuration and power consumptionRFM2002 Message RFM1014 MessageRFM1201 Message RFM2001 MessageSecurity may be compromised SEL0006 Message All event logging is disabled DetailsAppear if the user disabled event logging Power. If problem persists call supportTMP0121 Message Issues persists, contact supportFailed FailuresAlert Messages Diagnostic Messages172 Contacting Dell Getting Help
Related manuals
Manual 10 pages 54.11 Kb

T620 specifications

The Dell PowerEdge T620 is a versatile and powerful tower server designed to meet the demands of growing businesses and organizations. Launched as part of Dell’s 12th generation of PowerEdge servers, the T620 combines cutting-edge features, advanced technologies, and robust performance capabilities.

At its core, the T620 supports Intel's Xeon E5-2600 processors, providing exceptional computational power and efficiency. Organizations can choose from a range of CPUs, allowing them to customize their server according to specific workload requirements. The server can accommodate up to two processors, offering a substantial number of cores for multitasking and demanding applications.

One of the standout features of the T620 is its support for a significant amount of memory. It can house up to 768GB of DDR3 RAM across 24 DIMM slots. This ample memory capacity ensures that the server can handle memory-intensive applications with ease, making it suitable for virtualization, database management, and other critical tasks.

The T620 is equipped with several storage options, supporting up to sixteen 2.5-inch or eight 3.5-inch hard drives. This flexibility allows for high storage density and scalability, accommodating various storage configurations depending on the user’s needs. The system also supports both traditional SATA and high-speed SAS drives, making it adaptable for performance or capacity-driven environments.

Networking capabilities in the T620 are advanced, featuring embedded dual Gigabit Ethernet ports for reliable connectivity. This server supports multiple RAID configurations, enhancing data redundancy and performance. Additionally, the inclusion of Dell's iDRAC (Integrated Dell Remote Access Controller) ensures remote management and monitoring capabilities, allowing administrators to operate the server efficiently without being on-site.

The design of the T620 is built with expandability in mind. Its chassis offers flexibility for adding additional components, such as graphics cards and expansion cards, providing ample room for growth as organizational needs evolve.

In summary, the Dell PowerEdge T620 is a robust and flexible tower server that caters to the diverse needs of businesses. Its powerful processors, extensive memory options, versatile storage configurations, and advanced management features make it a reliable choice for companies seeking to enhance their IT infrastructure. The T620 stands out as a solid option for those looking to leverage technology for business success and growth.