Dell T620 owner manual Power Supplies

Page 84

6.Locate the processor socket.

7.If applicable, remove the socket protective cap.

8.Position your thumb firmly over the socket-release lever near the unlock first icon and release the lever from the locked position by pushing down and out from under the tab.

9.Similarly, release the socket-release lever near the close first icon from the locked position. Rotate the lever 90 degrees upward.

10.Hold the tab near the lock symbol on the processor shield and rotate it upward and out of the way.

11.Install the processor in the socket:

CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket.

a)Identify the pin-1 corner of the processor by locating the tiny golden triangle on one corner of the processor. Place this corner in the same corner of the ZIF socket identified by a corresponding triangle on the system board.

b)Align the pin-1 corner of the processor with the pin-1 corner of the system board.

c)Set the processor lightly in the socket.

CAUTION: Because the system uses a ZIF processor socket, do not use force. When the processor is positioned correctly, it drops down into the socket with minimal pressure.

d)Close the processor shield.

e)Rotate the socket-release lever near the unlock symbol until it is locked in position.

f)Similarly, rotate the socket-release lever near the lock symbol to the locked position.

CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and contaminating the processor socket.

12.If applicable, install the heat sink:

a)Open the grease applicator included with your processor kit and apply all of the thermal grease in the applicator to the center of the topside of the new processor.

b)Place the heat sink onto the processor.

c)Tighten the four screws to secure the heat sink to the system board.

NOTE: Do not over-tighten the heat sink retention screws when installing the heat sink. To prevent over- tightening, tighten the retention screw until resistance is felt, and stop once the screw is seated. The screw tension should be no more than 6 in-lb (6.9 kg-cm).

13.Install the cooling shroud.

14.Close the system.

15.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.

16.Press <F2> to enter the System Setup and check that the processor information matches the new system configuration.

17.Run the system diagnostics to verify that the new processor operates correctly.

Power Supplies

Your system supports either:

Two 495 W, 750 W, or 1100 W AC power supply modules or

Two 1100 W DC power supply modules

NOTE: Titanium power supply is nominally rated for 200 VAC to 240 VAC input only.

84

Image 84
Contents Regulatory Model E17S Series Regulatory Type E17S001 Dell Inc. All Rights Reserved Contents Installing System Components Wheel Assembly Optional-Tower ModeInternal USB Memory Key Optional Removing The Control Panel-Tower Mode Converting The System From Tower Mode To Rack Mode Troubleshooting Your SystemUsing System Diagnostics Jumpers And ConnectorsGetting Help Front-Panel Features And Indicators-Tower Mode About Your SystemIndicator, Button, or Icon Description Connector Inch hard Drive systemsFront-Panel Features And Indicators-Rack Mode S110 Software RAID LCD Panel Features Button DescriptionSetup Menu Home ScreenView Menu Hard-Drive Indicator Patterns Back-Panel Features And Indicators Back-Panel Features and Indicators1100 W NIC Indicator Codes Power Indicator CodesGreen Link indicator is Other Information You May Need Page Page Choosing The System Boot Mode Keystroke DescriptionF10 F11 F12Entering System Setup Responding To Error MessagesUsing The System Setup Navigation Keys System Setup Options System Setup Main ScreenSystem Bios Screen System Information ScreenMemory Settings Screen Processor Settings ScreenOption is set to Enabled Prefetcher option is set to EnabledExecute Disable Execute Disable option is set to EnabledSata Settings Screen Boot Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings Screen System Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Operating With a Setup Password EnabledEntering The Uefi Boot Manager Using The Boot Manager Navigation KeysBoot Manager Screen Exits the Boot Manager and proceeds with system bootIDRAC Settings Utility Entering The iDRAC Settings UtilityEmbedded System Management Changing The Thermal Settings Page Installing The Front Bezel Recommended ToolsFront Bezel Optional System Feet-Tower Mode Removing The Front BezelRemoving The System Feet Wheel Assembly Optional-Tower Mode Installing The System FeetInstalling The Wheel Assembly Removing The Wheel AssemblyRemoving and Installing the Wheel Assembly Opening And Closing The SystemOpening The System Closing The SystemInside The System Inside the SystemBezel Blank Removing The Bezel BlankInstalling The Bezel Blank Cooling ShroudRemoving The Cooling Shroud Installing The Cooling Shroud System MemoryProcessor Channel 0 slots A1, A5, and A9General Memory Module Installation Guidelines Dimm TypeOperating Frequency in MT/s Maximum Dimm Rank Channel Mode-Specific Guidelines Advanced ECC LockstepSample Memory Configuration Table Dimm Size NumberDIMMs Frequency B10, B11, B12 Removing Memory Modules B10, B11, B12Installing Memory Modules Flex BaysRemoving and Installing a Flex Bay Removing a Flex BayInstalling a Flex Bay Hard DrivesRemoving a 2.5 Inch Hard-Drive Blank Installing a 2.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive BlankRemoving a 3.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Hard-Drive Carrier Slim Optical Drive BlankRemoving The Slim Optical Drive Blank Installing The Slim Optical Drive Blank Optical Drives And Tape DrivesRemoving The Optical Drive Or Tape Drive Removing and Installing the Optical Drive or Tape Drive Cabling-Optical Drive and Tape Drive Installing The Optical Drive Or Tape Drive Cooling FansRemoving a Cooling Fan Installing a Cooling Fan Removing The Cooling-Fan Assembly OptionalInstalling The Cooling-Fan Assembly Optional Removing and Replacing the Cooling-Fan AssemblyInternal USB Memory Key Optional PCIe Card HolderReplacing The Internal USB Key Installing The PCIe Card Holder Removing The PCIe Card HolderGPU Card Holder Optional Removing The GPU Card HolderInstalling The GPU Card Holder Expansion Card Installation Guidelines Expansion CardsCard Priority Card Type Slot Priority Maximum Allowed GPU Card Installation Guidelines Removing An Expansion CardCard Priority Card Type Priority Maximum AllowedInstalling An Expansion Card Removing and Installing the Expansion CardRemoving a GPU Card Installing a GPU Card Removing and Installing the GPU CardSD vFlash Card Internal Dual SD ModuleReplacing An SD vFlash Card Removing and Installing the Internal Dual SD Module Removing An Internal Dual SD ModuleInstalling An Internal Dual SD Module Installing An Internal SD CardInternal SD Card Removing An Internal SD CardProcessors Removing a ProcessorRemoving and Installing a Processor Socket release lever Installing a Processor Power Supplies Hot Spare Feature Removing An AC Power SupplyInstalling An AC Power Supply Removing and Installing an AC Power SupplyWiring Instructions For a DC Power Supply Required ToolsAssembling The DC Input Power Wires Removing a DC Power Supply Assembling the DC Input Power WiresInstalling a DC Power Supply Removing and Installing a DC Power SupplyPower Interposer Board And Power Distribution Board Removing The Power Supply BlankInstalling The Power Supply Blank Removing The Power Interposer BoardRemoving The Power Distribution Board Removing and Installing The Power Interposer BoardInstalling The Power Distribution Board System Battery Installing The Power Interposer BoardReplacing The System Battery Removing and Installing the System Battery Hard-Drive BackplaneRemoving and Installing The PCIe SSD Hard-Drive Backplane Removing The Hard-Drive BackplanePower cable Power connector on backplane Power connector SAS a connector on Perc card Power connector on PDB 100 PCIe C cable Cabling-3.5 Inch x8 Plus 2.5 Inch x4 SAS/SATA Backplane SAS B cable Backplane Release pin 103 Cabling-3.5 Inch x12 SAS/SATA Backplane Removing and Installing 2.5 Inch x16 SAS/SATA Backplane Cabling-2.5 Inch x16 SAS/SATA Backplane Signal cable Backplane PCIe a cable 107 PDB SAS a cable Backplane SAS B cable Signal cable 109 SAS a connector on 2nd Perc SAS B cable Backplane SAS A1 cable SAS B1 cable 111 Backplane 2 SAS a connector Installing The Hard-Drive Backplane System Top CoverRemoving The System Top Cover Installing The System Top Cover System Left Side CoverRemoving The System Left Side Cover Installing The System Left Side Cover Control PanelRemoving The Control Panel-Tower Mode Removing and Installing the Control Panel-Tower ModeInstalling The Control Panel-Tower Mode Removing The Control Panel-Rack ModeControl panel module Screw Installing The Control Panel-Rack Mode Removing The Control-Panel BoardInstalling The Control-Panel Board LCD ModuleRemoving The LCD Module-Tower Mode Removing and Installing the LCD Module in the Tower ModeInstalling The LCD Module-Tower Mode Removing The LCD Module-Rack ModeInstalling The LCD Module-Rack Mode VGA ModuleRemoving and Installing the VGA Module Removing The VGA ModuleInstalling The VGA Module System BoardRemoving The System Board Installing The System Board Removing the System BoardPage 128 Converting The System From Tower Mode To Rack Mode Safety InstructionsRemoving and Installing the Rack Slide Cover Attaching the Mylar Cover Removing and Installing the System Ears Troubleshooting External Connections Troubleshooting The Video SubsystemTroubleshooting a USB Device Troubleshooting a Serial I/O Device Troubleshooting a NICTroubleshooting a Wet System Troubleshooting a Damaged SystemTroubleshooting The System Battery Troubleshooting Power SuppliesTroubleshooting Cooling Problems Troubleshooting Cooling FansTroubleshooting System Memory Troubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting An Optical Drive Troubleshooting a Hard Drive Troubleshooting Expansion CardsTroubleshooting Processors 142 Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic Controls Least one event description is recordedSystem Board Jumper Settings JumperSystem Board Connectors Connector DescriptionIDRACRJ45 Disabling a Forgotten Password Expansion Bus Expansion slotsMemory Drives Or Sata hard drivesConnectors Back Expanded Operating TemperatureFront InternalEnvironmental Temperature Temperature Continuous OperationRelative Humidity Maximum VibrationEnvironmental Maximum ShockMaximum Altitude Operating Altitude De-ratingCopper Coupon Corrosion Rate System Error Messages LCD MessagesViewing LCD Messages Removing LCD MessagesError Code AMP0302 MessageDetails ActionASR0003 Message BAT0002 MessageBAT0017 Message CPU0000 MessageCPU0010 Message CPU0023 MessageCPU0204 Message CPU0700 MessageException is external to the processor CPU0703 MessageCPU0704 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0000 Message MEM0001 MessageMEM0007 Message MEM0701 MessageMEM1208 Message MEM8000 MessagePCI1302 Message PCI1304 MessagePCI1320 Message PCI1342 MessagePCI1348 Message PCI1360 MessagePST0128 Message PST0129 MessagePSU0001 Message PSU0002 MessagePSU0006 Message PSU0016 MessagePSU0031 Message PSU0032 MessagePSU0034 Message PSU0035 MessagePSU0036 Message PSU0037 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Security may be compromisedIssues persists, contact support FailedFailures TMP0121 MessageDiagnostic Messages Alert Messages172 Getting Help Contacting Dell
Related manuals
Manual 10 pages 54.11 Kb

T620 specifications

The Dell PowerEdge T620 is a versatile and powerful tower server designed to meet the demands of growing businesses and organizations. Launched as part of Dell’s 12th generation of PowerEdge servers, the T620 combines cutting-edge features, advanced technologies, and robust performance capabilities.

At its core, the T620 supports Intel's Xeon E5-2600 processors, providing exceptional computational power and efficiency. Organizations can choose from a range of CPUs, allowing them to customize their server according to specific workload requirements. The server can accommodate up to two processors, offering a substantial number of cores for multitasking and demanding applications.

One of the standout features of the T620 is its support for a significant amount of memory. It can house up to 768GB of DDR3 RAM across 24 DIMM slots. This ample memory capacity ensures that the server can handle memory-intensive applications with ease, making it suitable for virtualization, database management, and other critical tasks.

The T620 is equipped with several storage options, supporting up to sixteen 2.5-inch or eight 3.5-inch hard drives. This flexibility allows for high storage density and scalability, accommodating various storage configurations depending on the user’s needs. The system also supports both traditional SATA and high-speed SAS drives, making it adaptable for performance or capacity-driven environments.

Networking capabilities in the T620 are advanced, featuring embedded dual Gigabit Ethernet ports for reliable connectivity. This server supports multiple RAID configurations, enhancing data redundancy and performance. Additionally, the inclusion of Dell's iDRAC (Integrated Dell Remote Access Controller) ensures remote management and monitoring capabilities, allowing administrators to operate the server efficiently without being on-site.

The design of the T620 is built with expandability in mind. Its chassis offers flexibility for adding additional components, such as graphics cards and expansion cards, providing ample room for growth as organizational needs evolve.

In summary, the Dell PowerEdge T620 is a robust and flexible tower server that caters to the diverse needs of businesses. Its powerful processors, extensive memory options, versatile storage configurations, and advanced management features make it a reliable choice for companies seeking to enhance their IT infrastructure. The T620 stands out as a solid option for those looking to leverage technology for business success and growth.