Operation

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400w Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 800w Peak efficiency (12V – 12 load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 88% Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 83% No load current draw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5A (12.6V) Output waveform (resistive load) . . . . . . . . . . . . . . . . . . . . . . . . . . . Modified sine wave Output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ Output voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109V – 120V Input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC Alarm voltage (unload) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.2V – 10.8V Shutdown voltage (unload) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2V – 9.8V Operating temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0°C – 40°C

(32°F – 104°F) Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C – 85°C (-40°F – 185°F)

Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overload, short-circuit, overtemp, reverse polarity, under/over voltage

Notes

All protection must be reset.

To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V.

To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases.

The unit is completely insulated in input and output for added safety.

Warranty

Warranty

Limited 1-Year Warranty

For Products Purchased In the U.S.A.

Cobra® Electronics Corporation warrants that its CobraMarinePower Inverter, and the component parts thereof, will be free of defects in workmanship and materials for a period of one (1) year from the date of first consumer purchase. This warranty may be enforced by the first consumer purchaser, provided that the product is utilized within the U.S.A.

Cobra® will, without charge, repair or replace, at its option, defective power inverters, products or component parts upon delivery to the Cobra® Factory Service department, accompanied by proof of the date of first consumer purchase, such as a duplicated copy of a sales receipt.

You must pay any initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra®’s expense, if the product is repaired or replaced under warranty. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.

Exclusions: This limited warranty does not apply: 1) To any product damaged by accident;

2)In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs; 3) If the serial number has been altered, defaced, or removed; 4) If the owner of the product resides outside the U.S.A.

All implied warranties, including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty. Cobra® shall not be liable for any incidental, consequential or other damages; including, without limitation, to damages resulting from loss of use or cost of installation.

Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.

For Products Purchased Outside the U.S.A.

Please contact your local dealer for warranty information.

18 English

Nothing comes close to a Cobra® 19

Image 12
Contents How Your CobraMarine Power Inverter Works Our Thanks To YouCustomer Assistance Operators English and Spanish Controls/Indicators and Product Features Table of ContentsImportant Safety Information Important Safety InformationGround Fault Circuit Interrupter Gfci Outlet CobraMarine M400 Output WaveformQuick Evaluation Before Installation Quick Evaluation Before InstallationTo Check Your Inverter’s Performance Before Installation Be Sure to Have on HandInstallation Requirements MountingConnecting Cables Connecting CablesTo Connect the Cables Between the Inverter and the Battery Power Consumption Power ConsumptionTo Determine the Battery Ampere-Hour Capacity You Require Power x Operating Time = Watt-HoursGround Wiring Power On or OffPower and Protection Indicators Gfci OutletOperating Limits Troubleshooting Guide Operating Limits Power OutputTroubleshooting Guide Problem/Symptom Possible Causes Input VoltageSpecifications WarrantySpecifications Limited 1-Year Warranty For Products Purchased In the U.S.AMaintenance and Product Service Product ServiceMaintenance Accessories and Order Form Amount Shipping/Handling
Related manuals
Manual 14 pages 15.97 Kb