The inverter must be installed in an area that meets all of the following requirements:

A.Dry

Do not place in an area where water can drip or splash on the inverter.

B.Cool

Ambient air temperature should be between 30°F and 105°F (0°C and 40°C). The cooler the better.

C.Ventilate

Allow at least 1 inch (3 cm) of clearance around the inverter for proper airflow. Make sure that ventilation openings on the ends of the unit are not obstructed.

CAUTION To avoid fire, do not cover or obstruct ventilation openings. Do not install inverter in a zero-clearance compartment. Overheating may result.

CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery.

WARNING This unit contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment.

6 English

Mounting

Installation

Mounting

To Mount Your Inverter:

1.Place the inverter on a flat surface with the mounting bracket against the mounting surface.

Mounting Brackets

2.Mount to secure surface using mounting hardware that is corrosion resistant (not included).

Mounting Hardware

The inverter can be mounted horizontally or vertically.

Nothing comes close to a Cobra® 7

Image 6
Contents How Your CobraMarine Power Inverter Works Our Thanks To YouCustomer Assistance Operators English and Spanish Controls/Indicators and Product Features Table of Contents Important Safety Information Important Safety InformationGround Fault Circuit Interrupter Gfci Outlet CobraMarine M400 Output WaveformTo Check Your Inverter’s Performance Before Installation Quick Evaluation Before InstallationQuick Evaluation Before Installation Be Sure to Have on HandInstallation Requirements MountingConnecting Cables Connecting CablesTo Connect the Cables Between the Inverter and the Battery To Determine the Battery Ampere-Hour Capacity You Require Power ConsumptionPower Consumption Power x Operating Time = Watt-HoursGround Wiring Power On or OffPower and Protection Indicators Gfci OutletTroubleshooting Guide Problem/Symptom Possible Causes Operating Limits Troubleshooting GuideOperating Limits Power Output Input VoltageSpecifications SpecificationsWarranty Limited 1-Year Warranty For Products Purchased In the U.S.AMaintenance and Product Service Product ServiceMaintenance Accessories and Order Form Amount Shipping/Handling