Cobra Electronics CPI M400 owner manual Ground Wiring, Power On or Off

Page 9

Ground Wiring

Installation

Ground Wiring

There is a screw on the rear panel for Chassis Ground. This is to connect the chassis of the inverter to ground.

The Chassis Ground Screw must be connected to a grounding point, which will vary depending on where the unit is installed. Use a #8 AWG copper wire (preferably with green/yellow insulation) to connect the chassis ground screw to the grounding point.

Chassis Ground

In a Vehicle:

Connect the Chassis Ground to the chassis of the vehicle.

In a Boat:

Connect to the Boat Grounding System.

In a Fixed Location:

Connect the Chassis Ground Screw to earth ground by connecting to a ground rod (a metal rod pounded into the earth) or other proper service entrance ground.

12 English

Power On or Off

Operation

Turning Your Inverter On or Off

Be sure to have your power inverter properly installed before attempting to turn the unit On (see “Installation” page 6).

To Turn the Power Inverter On:

1.If a DC power supply is being used as the power source, switch it On.

2.On the left side panel, switch the On/Off Switch to On.

On/Off Switch to On

The inverter is now ready to deliver AC power to your loads. If several loads are to be operated by the inverter, turn them On separately, after the inverter has been turned On. This will ensure that the inverter does not have to deliver the starting currents required for all the loads at once.

To Turn the Power Inverter Off:

1. On the left side panel, switch the On/Off Switch to Off.

On/Off Switch to Off

NOTE The On/Off Switch turns the control circuit in the inverter On and Off. It does not disconnect power from the inverter.

When the switch is in the Off position, the inverter draws no current from battery. When it’s in the On position, but no power is being supplied to the load, the inverter draws less than 500 milliamperes from the battery. This is low current draw. It would take more than a week to discharge a 100 ampere-hour battery at this rate depending on the age of the battery.

Nothing comes close to a Cobra® 13

Image 9
Contents How Your CobraMarine Power Inverter Works Our Thanks To YouCustomer Assistance Operators English and Spanish Table of Contents Controls/Indicators and Product FeaturesImportant Safety Information Important Safety InformationCobraMarine M400 Output Waveform Ground Fault Circuit Interrupter Gfci OutletQuick Evaluation Before Installation Quick Evaluation Before InstallationTo Check Your Inverter’s Performance Before Installation Be Sure to Have on HandMounting Installation RequirementsConnecting Cables Connecting CablesTo Connect the Cables Between the Inverter and the Battery Power Consumption Power ConsumptionTo Determine the Battery Ampere-Hour Capacity You Require Power x Operating Time = Watt-HoursPower On or Off Ground WiringGfci Outlet Power and Protection IndicatorsOperating Limits Power Output Operating Limits Troubleshooting GuideTroubleshooting Guide Problem/Symptom Possible Causes Input VoltageWarranty SpecificationsSpecifications Limited 1-Year Warranty For Products Purchased In the U.S.AMaintenance and Product Service Product ServiceMaintenance Amount Shipping/Handling Accessories and Order Form
Related manuals
Manual 14 pages 15.97 Kb