2.4Specifications
| ITEM |
|
|
| |||
|
|
|
|
|
|
|
|
1 | Printing method |
|
|
|
| Dot matrix method | |
|
|
| |||||
2 | Printing direction | ||||||
|
|
|
|
|
|
|
|
3 | Character configuration | (5 + 1) ⋅ 8 |
|
|
|
| (4 + 0.5) ⋅ 8 |
|
|
|
|
| |||
4 | No. of columns | 24 columns: 144 dots/line |
| 40 columns: 180 dots/line | |||
|
|
|
|
|
| ||
5 | Printing speed | Approx. 2.5 line/sec. |
|
| Approx. 1.8 line/sec. | ||
|
|
|
|
|
|
|
|
6 | Character size | l .62 ⋅ 2.4 mm |
|
|
|
| 1.08 ⋅ 2.4 mm |
|
|
|
|
|
|
|
|
7 | Line pitch | 3.52 mm |
|
|
|
|
|
|
|
|
|
| |||
8 | Paper | Roll paper |
| 57.5 ± 0.5 (W) ⋅ 50 (D)mm | |||
|
| Inner diameter |
| φ12 ± 1 mm | |||
|
|
| |||||
9 | Interface | Serial interface (RS232C) or parallel interface (Centronics) | |||||
|
|
|
|
|
|
|
|
10 | Input buffer | 2K byte |
|
|
|
|
|
|
|
| |||||
11 | Paper near end detection | When print paper goes to the near to end, the data receiving is stopped. And | |||||
|
| then printing is stopped after printing the data in the buffer. | |||||
|
|
| |||||
12 | Auto loading | When new paper is set into Paper inlet of Mechanism paper is automatically | |||||
|
| fed. |
|
|
|
|
|
|
|
| |||||
13 | International character codes | Character of 8 different countries is available by DIP switch setting. | |||||
|
| ( Japan/U.S./France/Germany/U.K/Italy/Spain/Denmark) | |||||
|
| By command setting, above countries plus additional one (Sweden) can be set. | |||||
|
|
|
|
|
|
|
|
14 | Ink ribbon | Purple |
|
|
|
|
|
|
|
| |||||
15 | Supply voltage | DC5V ± 5% (printing voltage) Approx. 2.5A | |||||
|
| Approx. 4A (duty 10%) at peak | |||||
|
| Use external power supply. |
|
| |||
|
|
|
|
| |||
16 | Average power consumption | At printing: |
| Approx. 7 VA | |||
|
| At no printing: |
| Approx. 0.7VA | |||
|
|
| |||||
17 | Weight | Approx. 500g (incl. mounting brackets) | |||||
|
|
| |||||
18 | External dimensions | 115 (W) ⋅ 65 (H) ⋅ 119 (D) mm | |||||
|
|
|
|
|
|
|
|
19 | Fitting hole dimensions | 109 (W) ⋅ 62 (H) | 0 |
| mm |
|
|
|
|
|
|
|
| ||
20 | Operating temperature | 0 ~ 40°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
21 | Storage temperature |
|
|
|
|
| |
|
|
|
|
| |||
22 | Safety and EMI Standard | For Europe: Safety Standard |
|
| |||
| Applied | TUV: EN60950: 1992 + A1 + A2 + 1993 | |||||
| (EMI is measured with packaged | For North America: EMI |
|
| |||
| power supply) |
|
|
| FCC class A | ||
|
|
|
|
| Safety Standard | ||
|
|
|
|
| UL: | USR UL/950 - 3th | |
|
|
|
|
| CNR CAN/CSA C22.2 No. | ||
|
|
|
|
|
|
|
|
10 | CITIZEN |