Overview of HILT 9000 Controls

Ready: 100%

Select Function

Figure 1

1.LOOP: Measures RDC, L, and Q. If Q>15, use Q push- button to obtain actual value.

2.Q: Measures high Q values (when Q is >15).

3.Used in SET FREQ mode to increase frequency by 1KHz.

4.Used in SET FREQ mode to decrease frequency by 1KHz.

5.POWER: Turns unit On/Off.

6.SET FREQ: Selects operating frequency to measure L & Q.

7.L: Measures change of inductance.

8.DETECTOR: Measures operating parameters of the

loop system: VP-P, Oscillating frequency, and mode.

9.Input: Color coded input connectors.

Image 5
Contents Hilt Handheld Inductive Loop Tester Table of Contents Packaging Receiving your ShipmentGeneral Description Detector Measures operating parameters Overview of Hilt 9000 ControlsLoop Function Controls PowerQuality Q Change of Inductance Set FrequencyDetector Button Description Comments Function Controls SummaryOverview of Traffic Loop Detection Systems Battery replacement Commonly Asked Questions When I run a Q test, why are there two results shown?Atsi Repair and CalibrationTechnical and Sales Assistance This page left blank Warranty Repair Limited Warranty