ATS HILT 9000 manual Function Controls Power, Loop

Page 6

HILT 9000 - Inductive Loop Tester

5

Function Controls

Power

Press the POWER push-button to turn the tester on and off. The tester performs an initial self-test to verify that the internal circuit is working. After the self-test is complete, the tester shows the current battery level and the message: Ready: Select Function. If the battery is low, a message Replace Battery will be displayed.

Press and hold the POWER push-button during power-up to display the serial number of the unit and the version of the firmware as show in Figure 2. Release

the push-button to return to normal

operation.HILT-9000 #1234 Self-test v.1.0

The unit can be turned off at any time

 

by pressing the POWER button. The

 

tester shuts off automatically after 30

 

seconds of non-use.

Figure 2

Loop

ATTENTION

Disconnect the detector from the loop before running this test.

DO NOT switch to a different test while the measure- ments are being generated for the current test. Only after the results of the current test are displayed can a different test be performed.

Connect the test leads to the loop. Press the LOOP push-button to begin the test. After the measurement is complete, the tester displays the results as shown in Figure 3 on the next page. Note that the frequency at which L and Q were measured is also displayed.

Image 6
Contents Hilt Handheld Inductive Loop Tester Table of Contents Receiving your Shipment PackagingGeneral Description Overview of Hilt 9000 Controls Detector Measures operating parametersFunction Controls Power LoopQuality Q Set Frequency Change of InductanceDetector Function Controls Summary Button Description CommentsOverview of Traffic Loop Detection Systems Battery replacement When I run a Q test, why are there two results shown? Commonly Asked QuestionsRepair and Calibration AtsiTechnical and Sales Assistance This page left blank Limited Warranty Warranty Repair