ArtDio IPS 1000 user manual IP Address Settings, System console settings Only for 4/8/16 ports

Page 15

IPS 1000 Series VoIP Gateway

5.Dial “9507#”Assuming you are modifying for China (The last 2 digits are the regional ID)

6.Dial “971#”Sets the new regional ID.

7.Hang up the phone. The device will be updated with the new region setting after it restarts (restart time is about 10 seconds)

9.1.2.System console settings (Only for 4/8/16 ports)

SIP-RG>enable SIP-RG #configure

Enter configuration commands, one per line. End with CNTL/Z SIP-RG(config)#regional_id 07

SIP-RG(config)#exit SIP-RG#delete nvram

This command resets the system with factory defaults.

All system parameters will revert to their default factory settings. All static and dynamic addresses will be removed.

Reset system with factory defaults, [Y]es or [N]o? Yes

Attention:

Before Changing the Region ID, the system has to be reset to the default value. Therefore this step should be done first.

The following instruction may keep the IP address unchanged after reset: “delete nvram keep_ip”

9.2.IP Address Settings

We recommend using a traditional phone to configure the unit’s parameters, as this is the easiest way. The following two sections contain the procedures used to configure the IPS unit according to how you obtain your IP address (Static IP; DHCP or PPPoE).

Attention:

Every time you set a parameter item and press the “#” key to complete it, a successful setting will be confirmed by three equal tones in succession. If your setting is unsuccessful you will be prompted with one long tone.

15

Image 15
Contents Version3.1 Update2004/5/7 IPS 1000 SeriesARTDio Company Inc Contents WEB Management Interface IP SettingSIP Outbound Authentication FAXSafety Instructions What is SIPPreface Components of SIP IPS 1000 Series VoIP Gateway Architecture Panel Descriptions Package ContentsRear Panel IPS 1103 Rear Panel 4 ports IPS 1101 Rear Panel 2 ports LED Indicators IDC Connectors Only for IPS-1000 series 8/16 ports ConnectorsIP Address Information required before InstallationSIP Information Prepare a password for Web ManagementInstallation and Configuration Phone SettingConfirming the Region ID System console settings Only for 4/8/16 ports IP Address SettingsStatic IP Mode PPPoE Mode Dhcp ModeUse WEB Interface to configure IPS 1000 Series VoIP Gateway Mosa WEBUpon entering the web based configuration interface IPS 1000 Series VoIP Gateway SIP Configuration IPS-1008 Channels and SIP entitySIP Entity SIP Proxy and Register ParametersSIP Outbound Authentication Configure Stun Phone Book Check SIP entity StatusMake SIP Calls Contact Address Other SIP Parameters Dialing PlanFXO FXS Call Forward Inbound AuthenticationFAX Devices at two sides are all IPS 1000 series gatewayDevices at two sides are IPS 1000 and the other brands SIP Outbound Home Basic General IP Setting AdvancedAuthentication Channel Phone Book Access CodeBasic / General RTP MACOFF IPSISP IP SettingWEB Dtmf Advanced / GeneralCadence On, off. The on and off SIP Common Pcmu PcmaCMU-PCMA RFC 2833 Dtmf SIP Outbound Authentication SIP Inbound Anthentication Dialing Plan Dialing Plan Stun Channel IPS 1000 Series VoIP Gateway Phone Book Use Private IP Behind NAT Appendix a Phone-Set Command AppendixDND IPS 1000 Series VoIP Gateway Enable Appendix B Console CommandEMI SpecificationsVAD, CNG RTP, RtcpMapping table of characters used in PPPoE USA Region IDTaiwan Contact Information