MODEL

 

 

KIN

 

KIN

KIN

 

KIN

 

KIN

 

 

 

800AP

 

1000AP

1200AP

 

1500AP

 

2200AP

INPUT

 

Capacity

800VA

 

1000VA

1200VA

 

1500VA

 

2200VA

 

 

Voltage

 

 

 

+/-25% at line

input

 

 

 

 

Frequency

 

 

50 or 60Hz +/-10% (auto sensing)

 

OUTPUT

 

Voltage

Simulated sine wave at 100V/110/115V/120V/220V/230V/240V

 

 

(on battery)

 

 

 

+/-5%

 

 

 

 

 

 

Frequency

 

 

 

50 or 60Hz +/-0.5%

 

 

 

(on battery)

 

 

 

 

 

 

 

 

 

 

Voltage

AVR automatically increase output voltage 15% above input

 

 

Regulation

voltage if -9% to-25% of nominal. AVR decrease output voltage

 

 

AVR

13% below input voltage if+9% to +25% of nominal

 

 

 

 

 

 

 

 

Transfer time

 

 

2/4 milliseconds, including detection time

PROTECTION

 

Spike Protection

 

 

 

320 Joules, 2ms

 

 

 

 

 

 

 

 

 

 

 

And

 

 

 

 

 

 

 

 

 

 

 

EMI/RFI filter

 

 

10dB at0.15MHz, 50dB at 30MHz

 

FILTERING

 

 

 

 

 

 

 

 

(for xxxAP models only)

 

 

 

 

 

 

 

 

 

Overload

UPS automatic shutdown if overload exceeds 110% of nominal at

 

 

Protection

 

 

60 second and 130% at 3 seconds.

 

 

Unit Input

Circuit breaker for overload & short circuit protection

 

 

10Base-T

 

 

Network (UTP, RJ-45)compatible jacks

 

 

Cable Port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short Circuit

UPS output cut off immediately or input circuit breaker protection

BATTERY

 

Type

 

 

Sealed, maintenance-free lead acid batteries

 

 

 

 

 

With 3-6 years typical lifetime

 

 

 

Typical

 

 

4 hours (to 90% of full capacity)

 

 

 

Recharge Time

 

 

 

 

 

 

 

 

 

 

Protection

Automatic self-test & Discharge protection, Replace battery

 

 

 

 

 

 

indicator

 

 

 

 

 

Back up Time

 

10 - 30 minutes (depending on computer load)

PHYSICAL

 

Net Weight

13

 

15

15.2

 

15.6

 

26.2

 

 

Kg(lbs)

(28.6)

 

(33.0)

(33.4)

 

(34.3)

 

(57.6)

 

 

Shipping Weight

14.2

 

16.2

16.4

 

16.8

 

28.2

 

 

Kg(lbs)

(31.2)

 

(35.6)

(36.1)

 

(36.9)

 

(62)

 

 

Dimension(mm)

 

 

130 x

382 x 201

 

 

 

169 x 448 x 227

 

 

WxDxH

 

 

 

 

 

 

 

 

 

 

Input Inlet

 

 

 

IEC 320 power inlet

 

 

ALARM

 

Battery

 

 

Slow beeping sound (about 0.47Hz)

 

 

Back-Up

 

 

 

 

 

 

 

 

 

 

Battery Low

 

 

Rapid beeping sound (about 1.824Hz)

 

 

Overload

 

 

Continue beeping sound

 

INTERFACE

 

RS-232

 

 

Bi-directional communication port

 

 

 

Interface

 

 

 

 

 

 

 

 

CONFORMANCE

 

Safety

 

 

Meet IEEE 587 standard

 

 

 

Surge

 

 

cUL, TUV, CE, meet FCC

 

ENVIRONMENT

 

Ambient

3,500 meters max. elevation, 0-95% humidity non-condensing

 

 

operation

 

 

 

0-48 deg C

 

 

 

 

 

Audible noise

 

 

<48dBA (1 meter from surface)

 

 

 

Storage

 

 

15000 meters max. elevation

 

 

 

condition

 

 

 

 

 

 

 

 

© 1999 Powercom Co., Ltd. All right Reserved. All trademarks are property of their respective owners. Specifications subject to change without notice.

14

Image 16
Contents USER‘S Manual Important safety instructions Please read this manualTable of contents Introduction Safety Presentation External Battery Pack Connector optional Rear PanelInstallation Charge the battery Check the Site Wiring Fault IndicatorConnect to Utility Connect the loadsOperation Alarm Back UP slow alarmLOW Battery rapid alarm Overload continuous alarmSoftware options Power Monitoring SoftwareInterface Kits SUB 9 Pin Female Connector for purpure cable SUB 9 Pin Female Connector for white cableComputer Interface Port Battery Replacement Troubleshooting StorageStorage conditions Extended storageSpecifications Page