CONNECTING CABLES

Connect the cables required to the appropriate connectors. Please make sure that each connector has to be connected to the right port in the right orientation. Some connectors have to be inserted till a click is heard such as the LAN connector, the external FDD connector, the power connector and the cash drawer connector. It is recommended to screw on the connector once it is inserted such as the external VGA connector, the LPT port connector and the COM port connectors. If COM1 port is to be used, you would have to take down the COM1 terminator that is already mounted on the COM1 port. However, it is highly suggested not to use for any serial device that does not provide proper handshaking signals such as a serial mouse in order to keep cash drawer control function. Adjust the slack of each cable and close the cable cover. Use the same latch key as when opening the cable cover but this time turn it clockwise on both sides to secure the cable cover on the main unit. Adjust the tilt angle of the main unit for best viewing effect in the application.

CAUTION: Before doing any insertion or extraction of the power plug, be sure to pull always the outer sleeve of the plug backward to release the internal latch. Failure to do this could damage the power plug. Such damage is considered as an artificial destruction and is not covered by the warranty.

INSTALLING CASH DRAWERS

When there is only one cash drawer to be installed, just connect the standard cable CCBLA-180 that comes with the cash drawer to the right RJ11C jack (be careful, not the adjacent one left for MODEM).

When there are two cash drawers to be installed, please purchase and use the optional split cash drawer control cable CCBLA-238 for the purpose of controlling two cash drawers in the TP6000 series. The CCBLA-238 has a 6 pole plug at one end and two 8 pole plugs at the other. The 6 pole plug should be inserted in the connector marked “CR” found in the rear compartment of the terminal. Each 8 pole plug should be inserted into the connector marked “signal cable from POS Printer” at the rear of one of the cash drawer. The cable lengths for the two 8 pole plugs are different. Use

TP6000 USER’S MANUAL 4 - 6

Image 22
Contents TP-6000 Series Some Important Notes Table of Contents Power ON/OFF USER’S Manual Product ConfigurationBrief Introduction OverviewStandard Features Optional Items TP6000 USER’S Manual 1 System BOX Contents Optional Devices Parts Identification Front ViewRight Side View Side ViewsLeft Side View Rear View Rear View of Main UnitBottom of Paddle Assembly Adjustable Paddle AssemblyConnectors PS/2 KB TP6000 USER’S Manual 3 Installation Guides Separating Main UnitPreparing Paddle Assembly Installing UPS Battery Routing the CablesPreparing the Main Unit Joining Main Unit and PaddleOpening Cable Cover Connecting Cables Installing Cash DrawersLocation for Installation Wall MountingPage Using the Touch POS Application EnvironmentSerial Port COM1 External MonitorSerial Port COM2 Power ON/OFF LED IndicatorPreset Power On Control Hardware SwitchSoftware Support Magnetic Stripe Reader Cash DrawersTouch Panel Display ResolutionTouch Terminal Manager RS232 Touch Monitor Mouse