Lochinvar 1.5, 1.3 4Fault History Screen, 1 Fault History Screen, PC Program Instructions

Page 8
4Fault History Screen

PC Program Instructions

4Fault History Screen

Figure 4-1Fault History Screen

The Fault History Screen provides historical data about the operation of the SMART TOUCH controls.. Click on the Fault history button along the top of the Main Screen window (FIG. 1-1), and then click on Read from Control in the pull-down menu. After uploading data from the selected program, a window will appear with the status of numerous counters and lists of the most recent events (see FIG. 4-1 above). Included are details of the control board serial number, software version, default parameters, production date, and last service date. The number of times various faults have occurred is also shown. The last 10 faults are listed, as well as the last 10 blockings (a blocking is an event that causes the burner to shut off). In addition, the number of hours the control has operated in various states is shown, as well as the number of successful and failed ignition attempts. Finally, a count of internal checks is shown.

The total number of occurrences of certain faults are also stored in the control and shown on the left side of the screen. The column on the right shows the total occurrences since the control was built. The column on the left shows the total occurrences since the table was reset. Press the Erase table button at the bottom of the window to clear the totals in the column on the left. This will also clear the Last 10 faults and the Last 10 blockings.

Some of this information may be needed by a service technician to diagnose a problem, so provision is made to create a file in which to save this data. Click on Save file, and define a file name and the folder in which to save it. A bitmap can also be saved by clicking on the Bitmap button at the bottom of the Fault History Screen (FIG. 4-1). The bitmap file will be saved to the folder ENCONFLS located below the file in which the SMART TOUCH program resides.

8

Image 8
Contents Models SYNC - PCP Rev ASave this manual for future reference PC PROGRAM INSTRUCTIONS FOR THE SYNCContents 1Installation Program installationUSB installation Program setupFigure 1-3 Password Window Starting the programFigure 1-1 SMART TOUCH PC Main Screen Figure 1-2 Sitecs937Lab Main ScreenPC Program Instructions 2Status ScreenFigure 2-1 SMART TOUCH Status Screen PC Program Instructions Figure 2-1 continued2Status Screen PC Program Instructions 3Graphics ScreenFigure 3-1 SMART TOUCH Graphics Screen PC Program Instructions 4Fault History ScreenFigure 4-1 Fault History Screen PC Program Instructions 5Cascade ScreenFigure 5-1 Cascade Screen Set 1 System Setup Set 2 Functional Data 6ParametersParameter information screens Set 4 Menu ValuesSet 1 System setup Ramp delay settings6Parameters continued Changeable parametersBlock time switching boiler on Block time switching boiler on/offBlock time Switch On/Off 2nd burner HW Set 2 Functional DataSet 4 Menu values Figure 6-5 Parameter Set 2EFigure 6-6 Parameter Set 4A Space Heating SH user setpoint User SetpShift OA reset curve Shift Air Reset Max service time Max Serv tSH off-ondifferential SH off/on df Offset HW setpoint to end HW demandTime to switch between HW and SH SH/HW sw tim Cascade max SH step power based Max outl tempConfig SH control Tank differential tempCascade Master controlled through ModBus Demand confReload short time ModBus out of order Figure 6-8 Parameter Set 4DNo. of months for service reminder Serv Not time Running hours for service reminder Serv NotRun hBurner cycles for service reminder Serv Not cycl Figure 6-10 Parameter Set 4FFigure 6-11 Outdoor Air Reset Curve BMS Power at min voltage BMS mod @minVBMS Power at max voltage BMS mod @maxV Figure 6-12 Parameter Set 4GBMS Voltage at min power BMS V @min mod BMS Voltage at max power BMS V @max modBMS Demand Enable 1 Voltage Storing parameters on your PCRevision Notes Revision A initial release
Related manuals
Manual 16 pages 3.68 Kb Manual 12 pages 30.87 Kb Manual 56 pages 20.39 Kb Manual 52 pages 37.07 Kb Manual 16 pages 33.86 Kb Manual 56 pages 40.75 Kb Manual 80 pages 59.46 Kb Manual 56 pages 36.01 Kb

1.5, 1.3, 1 specifications

Lochinvar 1 is a remarkable achievement in the realm of modern technology and engineering. As a powerful and efficient water heater, it has been designed to cater to a wide range of residential and commercial needs. One of the standout features of Lochinvar 1 is its advanced heating technology, which incorporates a high-efficiency condensing design. This technology allows the unit to achieve impressive energy savings by maximizing heat transfer while minimizing energy consumption.

The Lochinvar 1 utilizes a stainless steel heat exchanger that enhances durability and corrosion resistance. This not only extends the lifespan of the unit but also ensures consistent performance over time. Coupled with a user-friendly control system, users can easily adjust settings and monitor performance, enhancing overall convenience and usability.

Another key characteristic of the Lochinvar 1 is its compact design, making it suitable for a variety of installation environments. Whether in a residential basement or a commercial utility room, the unit’s space-saving configuration allows for efficient use of available area without compromising on capability.

Safety features are integral to the Lochinvar 1, providing peace of mind for users. The unit is equipped with advanced monitoring systems that can detect irregularities and automatically shut down the system if necessary. This not only protects the equipment but also enhances the safety of the environment in which it operates.

In terms of performance, Lochinvar 1 boasts a high recovery rate, ensuring hot water is available on demand. This is particularly beneficial for settings with high water usage, allowing simultaneous operations without lag.

Moreover, the unit supports various venting options, offering flexibility during installation. Whether using traditional vertical venting or innovations like direct venting, Lochinvar 1 accommodates different building designs and local codes, making it highly versatile.

In conclusion, Lochinvar 1 epitomizes the melding of efficiency, reliability, and user-friendly technology. With its high-performance features, robust safety systems, and adaptable installation options, it stands out as a forefront player in the water heating industry, meeting the diverse needs of today's consumers and businesses alike.