Lochinvar 1.3, 1.5 3Graphics Screen, 1 SMART TOUCH Graphics Screen, PC Program Instructions

Page 7
3Graphics Screen

PC Program Instructions

3Graphics Screen

Figure 3-1SMART TOUCH Graphics Screen

The Graphics Screen allows you to observe the changes in various readings while the heater operates (see FIG. 3-1). Note that the vertical scale has two numbers for each division. By default, the Outlet Temperature, Inlet Temperature, System Supply Temperature (if connected), Outdoor Temperature (if connected), Tank Sensor Temperature (if connected), Space Heating setpoint, Tank setpoint, 0-10Vdc input voltage, and fan speed are plotted.

In addition, the status of the Gas Valve Output, Flame Current, and Pump Outputs are indicated by horizontal lines. When these readings are off, the line is thin; when on, the line is wide. Any of these readings can be removed from the graph by deselecting them at the bottom of the window. The current values of these readings are also displayed at the bottom of the window as depicted in FIG. 3-1.

The time scale and vertical (Y) scale can be changed by clicking on the Options button to get the Options window, and then the Up or Down buttons for the desired scale. The top number represents °F, and the bottom number represents °C. Press the Ok button to close the Options window. The background color of the Graphics Screen can be changed by pressing the Display button on the Options window.

As with the Status Screen, a log file can be generated to record the performance of the appliance. Click on the Options button to open the Options window. Click on the LogFile button to create a file name and define the folder in which to put it. Once a Log File is defined, click on the Log button to start logging the readings. The Log button will turn green to indicate that the program is logging, and the log file size will appear at the top of the Graphics Screen window. Note that the file size will increase as more readings are logged. Click on the Log button again to stop logging of the readings. The Log button will turn gray again to indicate that logging has stopped.

A bitmap can also be generated of the Graphics Screen. Click on the Options button, and then the Bitmap button. A bitmap of the window will be saved into the C:/program files/SMART TOUCH PC/ENCONFLS directory.

7

Image 7
Contents PC PROGRAM INSTRUCTIONS FOR THE SYNC ModelsSYNC - PCP Rev A Save this manual for future referenceContents Program setup 1InstallationProgram installation USB installationFigure 1-2 Sitecs937Lab Main Screen Figure 1-3 Password WindowStarting the program Figure 1-1 SMART TOUCH PC Main ScreenFigure 2-1 SMART TOUCH Status Screen 2Status ScreenPC Program Instructions 2Status Screen Figure 2-1 continuedPC Program Instructions Figure 3-1 SMART TOUCH Graphics Screen 3Graphics ScreenPC Program Instructions Figure 4-1 Fault History Screen 4Fault History ScreenPC Program Instructions Figure 5-1 Cascade Screen 5Cascade ScreenPC Program Instructions Set 4 Menu Values Set 1 System Setup Set 2 Functional Data6Parameters Parameter information screensChangeable parameters Set 1 System setupRamp delay settings 6Parameters continuedSet 2 Functional Data Block time switching boiler onBlock time switching boiler on/off Block time Switch On/Off 2nd burner HWSpace Heating SH user setpoint User Setp Set 4 Menu valuesFigure 6-5 Parameter Set 2E Figure 6-6 Parameter Set 4AOffset HW setpoint to end HW demand Shift OA reset curve Shift Air ResetMax service time Max Serv t SH off-ondifferential SH off/on dfTank differential temp Time to switch between HW and SH SH/HW sw timCascade max SH step power based Max outl temp Config SH controlFigure 6-8 Parameter Set 4D CascadeMaster controlled through ModBus Demand conf Reload short time ModBus out of orderFigure 6-10 Parameter Set 4F No. of months for service reminder Serv Not timeRunning hours for service reminder Serv NotRun h Burner cycles for service reminder Serv Not cyclFigure 6-12 Parameter Set 4G Figure 6-11 Outdoor Air Reset CurveBMS Power at min voltage BMS mod @minV BMS Power at max voltage BMS mod @maxVStoring parameters on your PC BMS Voltage at min power BMS V @min modBMS Voltage at max power BMS V @max mod BMS Demand Enable 1 VoltageRevision Notes Revision A initial release
Related manuals
Manual 16 pages 3.68 Kb Manual 12 pages 30.87 Kb Manual 56 pages 20.39 Kb Manual 52 pages 37.07 Kb Manual 16 pages 33.86 Kb Manual 56 pages 40.75 Kb Manual 80 pages 59.46 Kb Manual 56 pages 36.01 Kb

1.5, 1.3, 1 specifications

Lochinvar 1 is a remarkable achievement in the realm of modern technology and engineering. As a powerful and efficient water heater, it has been designed to cater to a wide range of residential and commercial needs. One of the standout features of Lochinvar 1 is its advanced heating technology, which incorporates a high-efficiency condensing design. This technology allows the unit to achieve impressive energy savings by maximizing heat transfer while minimizing energy consumption.

The Lochinvar 1 utilizes a stainless steel heat exchanger that enhances durability and corrosion resistance. This not only extends the lifespan of the unit but also ensures consistent performance over time. Coupled with a user-friendly control system, users can easily adjust settings and monitor performance, enhancing overall convenience and usability.

Another key characteristic of the Lochinvar 1 is its compact design, making it suitable for a variety of installation environments. Whether in a residential basement or a commercial utility room, the unit’s space-saving configuration allows for efficient use of available area without compromising on capability.

Safety features are integral to the Lochinvar 1, providing peace of mind for users. The unit is equipped with advanced monitoring systems that can detect irregularities and automatically shut down the system if necessary. This not only protects the equipment but also enhances the safety of the environment in which it operates.

In terms of performance, Lochinvar 1 boasts a high recovery rate, ensuring hot water is available on demand. This is particularly beneficial for settings with high water usage, allowing simultaneous operations without lag.

Moreover, the unit supports various venting options, offering flexibility during installation. Whether using traditional vertical venting or innovations like direct venting, Lochinvar 1 accommodates different building designs and local codes, making it highly versatile.

In conclusion, Lochinvar 1 epitomizes the melding of efficiency, reliability, and user-friendly technology. With its high-performance features, robust safety systems, and adaptable installation options, it stands out as a forefront player in the water heating industry, meeting the diverse needs of today's consumers and businesses alike.