Lochinvar 1Installation, Program installation, USB installation, Program setup, PC Connection

Page 3
1Installation

1Installation

Program installation

There are two programs available for programming and monitoring the SYNC boilers. SITECS937Lab is used to monitor the operation of the boiler and program a few display- related parameters. SMART TOUCH PC is used to program the bulk of the parameters in the controls.

To begin installation of the programs, please insert your SMART SYSTEM CD into the CD drive. If you have Autostart enabled, the SMART SYSTEM software screen will load. If not, navigate to CD drive and double-click on index.html. Once the screen opens, select the program you wish to install. Follow the prompts, and after all the desired programs are installed, restart your computer.

If you wish to have the PC program icons on your desktop, click on START, and then Programs. Right click on SMART TOUCH PC. Place the cursor over Send to >, and then click on Desktop. Repeat this procedure for the SITECS937Lab program.

USB installation

Your PC will communicate with the SMART TOUCH control through the USB cable included with your kit. This cable will require a specific USB driver. This driver may be installed by starting the SMART TOUCH PC program, clicking on the Settings pull-down menu, and clicking on the Comport > item. In the next menu, you will have the option of installing one of two USB drivers. Select the option appropriate for the operating system used by your PC. The necessary driver will install automatically.

Program setup

The PC will assign a ComPort to your new adapter. You will need to know the ComPort number it uses in order to tell the SMART TOUCH PC program which one to communicate with:

1.Click on the following:

-Start

-Control Panel

-System icon (use the Classic View)

-Device Manager button

You will see a list of the hardware on your PC.

2.Double click on “Ports (COM&LPT)”. You will see an entry called “USB Serial Port (COM4)”. The ComPort number may be different on your computer but the device description will be the same. The SMART TOUCH PC program can communicate through Com- ports 1 - If the Comport assigned by your computer is avalue larger than what is available in the SMART TOUCH PC program, you will need to manually reassign the ComPort on your computer.

3. Go back to the “Ports (COM & LPT)” area referenced and take note of any unused ComPort between COM1 to COM16. Double click on the “USB Serial Port”.

PC Program Instructions

4.Click on the “Port Settings” tab, then on the “Advanced”button. Select an unused Comport number (preferably COM1) in the range of COM1 to COM16. Click on OK. Click OK on the previous window and then close all of the other windows.

5.Restart your PC to make sure the new ComPort number is active. When you attach the USB cable to the PC, the PC should recognize the cable. The next time you start up the SMART TOUCH PC and SITECS937Lab programs, click on the “Settings” tab at the top of the screen, then click on“Comport”. Select the ComPort number assigned to the USB cable above.

The programs display temperatures in °F. If you wish to display temperatures in °C, click on the Settings tab along the top of the Main Screen window, and move the cursor over Temperature > in the pull-down menu. A new menu will appear, click on Celsius.

￿ CAUTION

DO NOT connect a phone line to any of

 

the phone jacks on the control board.

PC to Unit Connection

There are three connectors in which to plug the serial communications cable on the SYNC unit (FIG. 1-a). Each one is specific to a particular function.

PC Connection

The PC connection is used to monitor the unit performance, data logging, programming the service provider’s name and phone number, and setting selected display parameters. Use the SITECS937Lab program for these functions.

PC1

The PC1 connection is used to retrieve, view, modify, and restore parameters for controller 1. Use the SMART TOUCH PC program for these functions.

PC2

The PC2 connection is used to retrieve, view, modify, and restore parameters for controller 2. Use the SMART TOUCH PC program for these functions.

Figure 1-aSMART TOUCH Cable Connections

PC1 CONNECTION TO VIEW AND

RESTORE PARAMETERS FOR

CONTROLLER 1.

PC2 CONNECTION TO VIEW AND

RESTORE PARAMETERS FOR

CONTROLLER 2.

PC CONNECTION FOR

MONITORING DATA LOGGING.

3

Image 3
Contents PC PROGRAM INSTRUCTIONS FOR THE SYNC ModelsSYNC - PCP Rev A Save this manual for future referenceContents Program setup 1InstallationProgram installation USB installationFigure 1-2 Sitecs937Lab Main Screen Figure 1-3 Password WindowStarting the program Figure 1-1 SMART TOUCH PC Main Screen2Status Screen Figure 2-1 SMART TOUCH Status ScreenPC Program Instructions Figure 2-1 continued 2Status ScreenPC Program Instructions 3Graphics Screen Figure 3-1 SMART TOUCH Graphics ScreenPC Program Instructions 4Fault History Screen Figure 4-1 Fault History ScreenPC Program Instructions 5Cascade Screen Figure 5-1 Cascade ScreenPC Program Instructions Set 4 Menu Values Set 1 System Setup Set 2 Functional Data6Parameters Parameter information screensChangeable parameters Set 1 System setupRamp delay settings 6Parameters continuedSet 2 Functional Data Block time switching boiler onBlock time switching boiler on/off Block time Switch On/Off 2nd burner HWSpace Heating SH user setpoint User Setp Set 4 Menu valuesFigure 6-5 Parameter Set 2E Figure 6-6 Parameter Set 4AOffset HW setpoint to end HW demand Shift OA reset curve Shift Air ResetMax service time Max Serv t SH off-ondifferential SH off/on dfTank differential temp Time to switch between HW and SH SH/HW sw timCascade max SH step power based Max outl temp Config SH controlFigure 6-8 Parameter Set 4D CascadeMaster controlled through ModBus Demand conf Reload short time ModBus out of orderFigure 6-10 Parameter Set 4F No. of months for service reminder Serv Not timeRunning hours for service reminder Serv NotRun h Burner cycles for service reminder Serv Not cyclFigure 6-12 Parameter Set 4G Figure 6-11 Outdoor Air Reset CurveBMS Power at min voltage BMS mod @minV BMS Power at max voltage BMS mod @maxVStoring parameters on your PC BMS Voltage at min power BMS V @min modBMS Voltage at max power BMS V @max mod BMS Demand Enable 1 VoltageRevision Notes Revision A initial release
Related manuals
Manual 16 pages 3.68 Kb Manual 12 pages 30.87 Kb Manual 56 pages 20.39 Kb Manual 52 pages 37.07 Kb Manual 16 pages 33.86 Kb Manual 56 pages 40.75 Kb Manual 80 pages 59.46 Kb Manual 56 pages 36.01 Kb

1.5, 1.3, 1 specifications

Lochinvar 1 is a remarkable achievement in the realm of modern technology and engineering. As a powerful and efficient water heater, it has been designed to cater to a wide range of residential and commercial needs. One of the standout features of Lochinvar 1 is its advanced heating technology, which incorporates a high-efficiency condensing design. This technology allows the unit to achieve impressive energy savings by maximizing heat transfer while minimizing energy consumption.

The Lochinvar 1 utilizes a stainless steel heat exchanger that enhances durability and corrosion resistance. This not only extends the lifespan of the unit but also ensures consistent performance over time. Coupled with a user-friendly control system, users can easily adjust settings and monitor performance, enhancing overall convenience and usability.

Another key characteristic of the Lochinvar 1 is its compact design, making it suitable for a variety of installation environments. Whether in a residential basement or a commercial utility room, the unit’s space-saving configuration allows for efficient use of available area without compromising on capability.

Safety features are integral to the Lochinvar 1, providing peace of mind for users. The unit is equipped with advanced monitoring systems that can detect irregularities and automatically shut down the system if necessary. This not only protects the equipment but also enhances the safety of the environment in which it operates.

In terms of performance, Lochinvar 1 boasts a high recovery rate, ensuring hot water is available on demand. This is particularly beneficial for settings with high water usage, allowing simultaneous operations without lag.

Moreover, the unit supports various venting options, offering flexibility during installation. Whether using traditional vertical venting or innovations like direct venting, Lochinvar 1 accommodates different building designs and local codes, making it highly versatile.

In conclusion, Lochinvar 1 epitomizes the melding of efficiency, reliability, and user-friendly technology. With its high-performance features, robust safety systems, and adaptable installation options, it stands out as a forefront player in the water heating industry, meeting the diverse needs of today's consumers and businesses alike.