5.6: USER DSP ON/OFF

A user DSP On/Off switch is provided on the amp panel. This miniature switch is recessed and can be easily activated with a small screwdriver.

The switch in the OFF position will return the VNET“ loudspeaker back to the original factory settings, this basically means that any parameter edited in software (EQ, Crossover, Mute, Delay) can be defeated by activating this switch. This can be a very useful feature. Example:-

In a large corporate production the networked loudspeakers are been used by an operator who has been using the Podware software for editing EQ & gain & delay; at the end of the performance he mutes the loudspeakers from within the software and the loudspeakers are returned to hire stock after the performance. Next day there is a rush for a small hire comprising only a couple of VNET“ loudspeakers. The speakers are taken to the small gig where the operator is not making use of the Networking, or Podware software in this particular instance. He realizes that he muted the loudspeakers the night before, and this particular pair had 100ms of delay applied!! All he has to do is flick the USER DSP switch to the OFF position (assuming he is carrying his Leatherman) and any of the USER editable parameters in Podware are defeated.

6.0: NETWORK CONNECTIONS

Interconnection between the network computer and the speakers is very straight forward, using twisted pair cable and simple connectors. The RS485 interface operates on a shared bus so that a single computer can control any amplifier on the bus, and the computer may gather status information from any device on the bus. Each module contains a unique address so that no user input will be required to configure network nodes.

It is only data that is carried over the network to control setup functions & ongoing system diagnostics, therefore if a network fault occurs, audio can still be delivered. This alleviates the problem of total system failure through a single system controller going down. As each loudspeaker controls it own DSP functions any unforeseen failure would be isolated to only that particular node .

example network

RS485

3rd party RS232/

USB to RS485 interface

VNET Series

VNET Series

RS485 link

RS485 link

VNET Series

VNET Series

RS485 link

RS-485 is standard for sending serial data. It uses a pair of wires to send a differential signal over distances up to 4000 feet (1200m) without a repeater. The differential signal makes it very robust, RS-485 is one of the most popular communications methods used in industrial applications where it s noise immunity and long-distance capability are a perfect fit.

IMPORTANT: Always run a signal ground with RS-485

Connection from the PC to the network is via a 3rd party RS232 to RS485 or USB to RS485 interface. These devices are readily available from your IT supplier. At the time of writing this manual extensive testing was carried out with the following devices:-

Tannoy USB — RS485 Converter (Part No. 8001 3920) K2 from KK (www.kksystems.com)

USB-COMi from Easysync (www.easysync.co.uk)

485 SD9R from B&B electronics (www.bb-elec.com)

8

Image 8
Contents Page Contents Important Safety Instructions Important Safety InstructionsInstallation Instructions IntroductionIntroduction Unpacking and Visual Checks Preliminary RecommendationInterface Panel OperationAC Power Requirements Audio ConnectionsUser DSP ON/OFF Network ConnectionsSoftware Installation Linking CabinetsForms Windows Services Recommended processor Installing the software from the CDScenario Required Processor Client Windows RecommendedInstallation Complete Menus FileDevice NetworkParameter Synchronisation Controlling DevicesDrop-Down Selector boxes Spin boxesButtons FadersConfiguration Name Model NameLoudspeaker name Firmware VersionProtection factory optimised Equalisation FiltersCrossover shapes Smooth adjustment Power on & OFFSaving & Recalling Data From the toolbar select Device & Start Firmware LoaderUpdating Firmware Equalisation ArrayingDimensions Vnet 15 BP Performance Data Technical Specifications SystemVnet 15BP Vnet 15HL Vnet 18DR Rigging Secur ET VMY Yoke BracketNumber on Assembly View Fig Description Quantity V15Y Terminal panel resulting in a more discrete installation Secur ET VMB Wall Mounting BracketImportant It is imperative for safety reasons that two Used per cabinet. VEB eyebolts should be installedBe installed on the top of the cabinet. Never suspend Eyebolts linked to two independently fixed straps areDescription Quantity Service Parts & Accessories Warranty Declaration of ConformityPage Page Page 0508