#O1

 

Disconnects if terminal buffer overflows

#O2

 

Disconnects if line buffer overflows

#O3

 

Disconnects if either buffer overflows

#PIN=n

 

Pin Number where n is the pin number

#R0

 

Remote Control Mode

#V0

 

Command and S Register verifier off

#V1

„

Command and S Register verifier on

%B0

„

S0=0 setting after AT&F

%B1

 

S0=2 setting after AT&F

%C0

 

Compression disabled

%C1

 

MNP 5 compression enabled

%C2

 

V.42bis data compression enabled

%C3

„

V.42bis data compression enabled with fallback to MNP 5

%Dn

 

Set disconnect delay to n seconds (default %D0)

%E0

 

Disable auto-retrain

%E1

„

Enable auto-retrain

%E2

 

Automatic Speed Stepping

%H0

„

Use B setting for initial MNP 10 connection speed

%H1

 

Initial connection is made at 1200 bps (MNP 10)

%H2

 

Initial connection is made at 4800 bps (MNP 10)

%H3

 

Initial connection is made at 9600 bps (MNP 10)

%H9

 

Use B setting for connection but do not upshift (MNP 10)

%K0

„

CTS operates normally

%K1

 

CTS off during dial and handshake

%L0

 

Report current received signal level (-dBm)

%Ln

 

Set transmit level (n=11 to 19; -11dBm to -19dBm)

%M0

„

Mode LEDs indicate connection speed

%M1

 

Mode LEDs indicate line quality, V.42/MNP errors & flow ctrl

%N0

„

Standard Baud Rates

%N1

 

Standard to 14400 then 20800, 31200, 41600 and 62400

%N2

 

Standard to 38400 then 51200

%P0

„

CONNECT message appears before DCD asserted

%P1

 

CONNECT message appears after DCD asserted

%Q

 

Report current line quality (EQM) (0=perfect)

%R0

„

&R command determines state of CTS

%R1

 

CTS always follows RTS (not reset by &F)

%R2

 

CTS follows DTR when offline (not reset by &F)

%S0

„

DSR is not overridden

%S1

 

DSR mimics the state of DTR (not reset by &F)

%T0

„

DCD always follows state of carrier

%T1

 

DCD is always high (not reset by &F)

%U0

„

Standard error correction response codes

%U1

 

V.42 response codes when V.42 connection established

%U2

 

V.42 response codes for V.42 connections, MNP 2,4,10 compression

%W0

„

Disable welcome message

%W1

 

Send message specified by *W to remote modem after connect

\A0

 

MNP block size = 64

\A1

 

MNP block size = 128

\A2

 

MNP block size = 192

\A3

„

MNP block size = 256

\Bn

 

Send Break sequence to remote modem (default \B3)

MIU56Robert Way

Page 16

2/28/2003

Image 16
Contents MIU56 Table of Contents Industrial Modem MIU56 User Guide Legal & Regulatory Information Copyright InformationIntroduction Modem Controls and Indicators Links Internal controlsPstn OUTPower Down Feature Modem FeaturesDial and Talk Feature How to Load the Voice Alarm Messages Voice Messaging SystemAT#MEM1 AT#MEM2Remote Voice Setting of Alarm Messages Asynchronous Mode Synchronous ModeOperating Modes Line SpeedsLeased Line Operation Commands Modem AT CommandsDial Modifiers General Commands Speaker on during dial, answer, retrain or rate change #MEM0 #MEM1#MEM2 #MINIDisable welcome message Modulation Setting Mod Modulation Possible Rates bpsAT-SDR=0 Distinctive RingAT-SDR=7 Response Codes Registers AsciiSpecifications Data Compression EncryptionEnvironmental Humidity