4. POWER SUPPLY SPECIFICATIONS

The MIUXXX/485 contains a low quiescent power regulator. TheMIUXXX/485 also has a "low power" standby mode which minimizes overall power requirements when the MIUXXX/485 is used intermittently.

4.1Power Supply Selection (MIU) The power supply is selected through the use of a 3-pin screw - type terminal connector.

Power Connector P3 (MIU)

 

Connector Type:

3 Pin screw- type terminal

Regulated Powe r Supply Range: 48.0 to 220 Volts AC/DC.

Standby Supply Currents:

200uA

Active Supply Currents:

8mA to 40mA plus modem current

In-Rush Current:

< 250mA

Reverse Protection Method:

Full wave Bridge Rectifier

Over-Voltage Clamp limits:

Zener diode

Regulated Power Supply Range: (12 - 24VDC) is available as an option

Standby Supply Currents:

200uA

Active Supply Currents:

35mA to 295mA plus modem current

In-Rush Current:

< 350mA

Reverse Protection Method:

Full Wave Bridge Rectifier

Over- Voltage Clamp limits:

Zener diode and TransZorb TVS

Install Op and Diags for MIU Modems and RS485 (0049-0002-010A)

Page 4 of 16

Image 6
Contents Installation, Operation and Diagnostics Table of Contents Product Overview Product DescriptionRS485 Configuration Connector P1 Mius LED, Switch & Serial Connector SpecificationsRS-232 Configuration Connector P2 LEDSB-1 Closed on RS485 Received RX & /RX Power Connector P3 MIU Regulated Powe r Supply Range 48.0 to 220 Volts AC/DCEnvironmental Specifications Speed DistanceApprovals MIUXXX\485 Power Connection Sheet TWOMIUXXX/485 DIP Switch Setup Appendix A.CONNECTOR PIN Definitions Connector P2 RS-232 Configuration Connector DB9 MIUModule C-1 MIU S3 external Appendix C. Connector Diagostics RS485 Connection FailureDiagnostics RS485 Connection Failure