Telenetics MIU Dial or Leased Line modem with RS-485 manual MIU S3 external

Page 14

&Z3=XX Password to exit security mode

&C1

Carrier Detect is always True (MIU LED will be ON all the time

 

when Carrier Detect is ON.

&D0

DTR is ignored

&K0

No flow control

4:AT Command (MIU9.6L/485) Lease Line

ATE0Q1&C1&D0&K0&Q6\M0\H1W0

E0

Echo Command disables (no "AT" response to terminal)

Q1

Result Codes disable (no result codes return to terminal ring,

 

Connect (XXX)

&Q6

Normal mode (speed buffering)

\M0

Answer mode (for Remote (Slave)unit) local (Master) set for

 

originate \M1

\H1

Lease Line mode

\S1

Security mode (Not available for MIU9.6L)

&C1

Carrier Detect is always true (MIU LED will be ON all the time when

 

Carrier Detect is ON.

&D0

DTR is ignored

&K0

No flow control

Note &Q5 error detection and data compression can be used

If the host software will support EC

Switch Setting (MIUXXX/485) (Typical)

MIU S3 (external)

SW-1 Closed (ON) MIU is configured for RS485 Module (RS485 RxD (Output) to Modem TxD (input))

SW-2, -3 & -4 Open (OFF)

2- Wire Configuration on PE485 module

SB-1 Closed (ON) DC Termination Open (OFF) AC Termination

SB-2 Closed (ON) Line Termination

SB-3 & -4 Closed (ON) 2- Wire

SA- 1 Open (OFF)

SA- 2 Closed (ON) TxD (transmit data) enables TX (Driver Output Enable) + 5ms SA- 3 Open (OFF)

SA- 4 Closed (ON) Received data is disable with TX enable (TxD)

4- Wire Configuration for PE485 module

CIU Installation, Operation & Diagnostics

Edition: June 17, 2003

Page C-1

Image 14
Contents Installation, Operation and Diagnostics Table of Contents Product Overview Product DescriptionRS485 Configuration Connector P1 Mius LED, Switch & Serial Connector SpecificationsRS-232 Configuration Connector P2 LEDSB-1 Closed on RS485 Received RX & /RX Power Connector P3 MIU Regulated Powe r Supply Range 48.0 to 220 Volts AC/DCEnvironmental Specifications Speed DistanceApprovals MIUXXX\485 Power Connection Sheet TWOMIUXXX/485 DIP Switch Setup Appendix A.CONNECTOR PIN Definitions Connector P2 RS-232 Configuration Connector DB9 MIUModule C-1 MIU S3 external Appendix C. Connector Diagostics RS485 Connection FailureDiagnostics RS485 Connection Failure