Telenetics MIU Dial or Leased Line modem with RS-485 manual Diagnostics RS485 Connection Failure

Page 16

To test RS485 module set switch SB-3 & -4 Closed (ON) to loopback data to the host modem. This test is for RS485 2- wire and 4- wire configurations.

Connect MIUXXXX/485 TXY (+) and TXZ (-) to the embedded controller

RS485

DIAGNOSTICS

RS485 CONNECTION FAILURE

To test RS485 module set switch SB-3 & -4 Closed (ON) to loopback data to the host modem. This test is for RS485 2- wire and 4- wire configurations.

Connect MIUXXXX/485 TXY (+) and TXZ (-) to the embedded controller RS485 connection

MIUXXXX/485 + -------------------

+ RS485 embedded controller

-

------------------- -

 

In some applications RS485

TXY (+) and TXZ (-) may have to be connected

to RS485

embedded controller

in the following setup

MIUXXX/485 +

----------------- - RS485 embedded controller

 

- ----------------- +

 

CIU Installation, Operation & Diagnostics

Edition: June 17, 2003

Page C-1

Image 16
Contents Installation, Operation and Diagnostics Table of Contents Product Overview Product DescriptionMius LED, Switch & Serial Connector Specifications RS-232 Configuration Connector P2RS485 Configuration Connector P1 LEDSB-1 Closed on RS485 Received RX & /RX Power Connector P3 MIU Regulated Powe r Supply Range 48.0 to 220 Volts AC/DCEnvironmental Specifications Speed DistanceApprovals MIUXXX\485 Power Connection Sheet TWOMIUXXX/485 DIP Switch Setup Appendix A.CONNECTOR PIN Definitions Connector P2 RS-232 Configuration Connector DB9 MIUModule C-1 MIU S3 external Appendix C. Connector Diagostics RS485 Connection FailureDiagnostics RS485 Connection Failure