Telenetics MIU Dial or Leased Line modem with RS-485 manual C-1

Page 13

1:AT Command (MIU2400/485) (Dial) configuration is:

ATE0Q1&C1&D0S0=1&W0

E0

Echo Command disables (no "AT" response to terminal)

Q1

Result Codes disable (no result codes return to terminal ring)

S0=1

Auto Answer active (first ring modem will go OFF- Hook and

 

start answer sequence)

&C1

Carrier Detect is always True (MIU LED will be ON all the

 

time when Carrier Detect is ON.

&D0

DTR is ignored

2:AT Command (MIU2496/485, MIU14.4/485 & MIU28.8/485)

ATE0Q1&C1&D0&Q6S0=1&W0

E0

Echo Command disables (no "AT" response to terminal)

Q1

Result Codes disable (no result codes return to terminal ring,

 

Connect XXX)

&Q6

Normal mode (speed buffering)

S0=1

Auto Answer active (first ring modem will go OFF- Hook

and start answer sequence)

&C1

Carrier Detect is always True (MIU LED will be ON all the

 

time when Carrier Detect is ON.

&D0

DTR is ignored

&K0

No flow control

3:AT Command (MIU14.4L/485) Lease Line

ATE0Q1&C1&D0&K0&Q6\M0\H1&Z3=XX&W0

Recycle power (OFF ON)

Wait 5 seconds for DSR to switch ON

Enter AT\S1 <CR>

AT&W0 <CR>

Within 45 seconds

E0

Echo Command disables (no "AT" response to terminal)

Q1

Result Codes disable (no result codes return to terminal ring,

 

Connect XXX)

&Q6

Normal mode (speed buffering)

\M0

Answer mode (for Remote (Slave unit) local (Master) set for

 

originate \M1

\H1

Lease Line mode

\S1

Security mode (if remote RTU is a dumb unit - TxD is always ON

 

 

CIU Installation, Operation & Diagnostics

Edition: June 17, 2003

Page C-1

Image 13
Contents Installation, Operation and Diagnostics Table of Contents Product Description Product OverviewRS-232 Configuration Connector P2 Mius LED, Switch & Serial Connector SpecificationsRS485 Configuration Connector P1 LEDSB-1 Closed on RS485 Received RX & /RX Regulated Powe r Supply Range 48.0 to 220 Volts AC/DC Power Connector P3 MIUSpeed Distance Environmental SpecificationsApprovals Sheet TWO MIUXXX\485 Power ConnectionMIUXXX/485 DIP Switch Setup Connector P2 RS-232 Configuration Connector DB9 MIU Appendix A.CONNECTOR PIN DefinitionsModule C-1 MIU S3 external RS485 Connection Failure Appendix C. Connector DiagosticsDiagnostics RS485 Connection Failure