Options:

STUDER INNOTEC

Options:

Alarm contact

A contact with no potential (0,5A - 60V) is available (12). It warns the user (alarm or control system) when the inverter has been stopped due to a failure or is out of use. It is closed when the inverter is working.

Solar charge controller

This controller has been designed to charge the batteries with solar installation only. The maximum no load tension of the solar installation should be of 23V for the 12V applications and of 46V for the 24V applications. The max. DC current is 16A and should never be exceeded (20A / 1min.). The mode of adjustment is of the I/U + "floating" type and assures optimal charging conditions for the life

Charging diagram

of the battery.

LED “ Charging ” (11) :

It is illuminated when the solar module provides current to charge or maintain the battery.

LED “ Bat. 100% ” (10) :

It is illuminated when the battery has reached its max. tension (14,4V or 28,8V). It goes off when the tension is above 13V (26V).

SI

Maintenance

The SI inverters do not need any special maintenance. The casing may be cleaned with a damp cloth (not wet).

In the case of malfunction, the inverter should be sent to the salesperson for control.

Legislation

In all cases the assembly and installation must be done by qualified technicians, observing the national requirements and rules stipulated. You will find complete information about this in the relevant institutions.

Limitation of liability

STUDER INNOTEC cannot control the installation, use and maintenance of the inverter. Thus, we are not responsible for damages, costs or losses resulting from an installation

which is not in accordance with the regulations or inappropriate use or maintenance.

The customer is always responsible for the use of the inverters STUDER INNOTEC.

This device has not been designed and is not warranted for use in life support apparatus or any other critical apparatus with potential risks of serious harm to

people or to the environment.

We do not accept any responsibility for any violation of patent rights or other third person rights resulting from the use of the inverter.

STUDER INNOTEC reserves the right to modify their products without previous notice.

CE- declaration of conformity

I declare under that products mentioned on page 11 of this manual are in conformity with the following standards or standardisation documents :

EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, Dir. 89/336/EEC, LVD 73/23/EEC

 

 

Roland Studer

Sion : June 19th, 1999

 

Studer Innotec

 

 

 

 

 

User manual

SI V3.0 E

6

Image 6
Contents Users and Installers Handbook STUDER INNOTECSTUDER INNOTEC SI SERIESRed Fault - LED WIRING DIAGRAM FOR SI 600 - 800 S SOLAR CHARGE REGULATORAdjustment procedure DESCRIPTION AND WIRING DIAGRAMApplications and Performance After disconnecting the battery, the outputIntroduction Product presentationCheck the tension and polarity of the battery AssemblyRemote control ConnectionIndicators SafetyAdjustments Adjustment procedureOptions MaintenanceAlarm contact LegislationDescription and wiring diagram Wiring diagram for SI 600 - 800 S Solar charge regulator Working Option SI performance 3-phasedConnecting Commissioning1624 STUDER INNOTECSI1212 2324