SSI America ERP2U manual Input Under Voltage, Efficiency, AC Line Dropout, AC Input Rating

Page 12

SSI

ERP2U Power Supply Design Guide, V2.31

Table 3: AC Input Rating

PARAMETER

MIN

RATED

MAX

Voltage (110)

90 Vrms

100-127 Vrms

140

Vrms

 

 

 

 

 

 

Voltage (220)

180

Vrms

200-240 Vrms

264

Vrms

 

 

 

 

 

 

Frequency

47

Hz

 

63

Hz

 

 

 

 

 

 

5.4Input Under Voltage

STATUS

Required

The power supply shall contain protection circuitry such that application of an input voltage below the minimum specified in section 5.3 shall not cause damage to the power supply.

5.5Efficiency

STATUS

Recommended/Required

The following table provides recommended and required minimum efficiency levels. These are provided at three different load levels; 100%, 50% and 20%. The “required” minimum efficiency levels are for the purpose of proper power supply cooling when installed in the system. The “recommended” minimum efficiency levels are for the purpose of reducing the system’s AC power consumption. The efficiency is specified at 50% and 20% loading conditions to help reduce system power consumption at typical system loading conditions.

Efficiency shall be tested at AC input voltages of 115VAC and 230VAC. Refer to www.efficientpowersupplies.org for details on proper efficiency testing methods.

 

Table 4:

Efficiency

Loading

100% of maximum

 

50% of maximum

Required minimum

70%

 

72%

Recommended minimum

80%

 

83%

20% of maximum

65%

78%

5.6AC Line Dropout

STATUS

Required

An AC line dropout is defined to be when the AC input drops to 0 VAC at any phase of the AC line for any length of time. During an AC dropout of one cycle or less the power supply must meet dynamic voltage regulation requirements up to 75% of the rated output load. An AC line dropout of one cycle or less shall not cause any tripping of control signals or protection circuits. If the AC dropout lasts longer than one cycle or the load is greater than 75%, the power supply should recover and meet all turn on requirements. The power supply must meet the AC dropout requirement over rated AC voltages, frequencies, and output loading conditions. Any dropout of the

- 12 -

Image 12
Contents SSI ERP2U Power Supply Design Guide Disclaimer Contents Error! Bookmark not defined TablesFRU Device Product Information Area Purpose Conceptual OverviewDefinitions/Terms/Acronyms Required Mechanical Overview Required OptionalTemperature Requirements Recommended Acoustic Sound Power LevelsAcoustic Requirements Airflow RequirementsAC Inlet Connector AC Input Voltage SpecificationAC Input Requirements Redundant AC InletsInput Under Voltage EfficiencyAC Line Dropout AC Input RatingAC Line Transient Specification AC Line FuseAC Inrush AC Line Sag Transient PerformanceAC Line Fast Transient Specification AC Line Surge Transient PerformanceAC Line Surge DC Output Specification Output ConnectorsRequired Baseboard power connector P1 Baseboard Power Connector2 +12V4 Baseboard Power Connector Required Peripheral Power ConnectorsRequired Floppy Power Connector Peripheral Power ConnectorsSerial ATA Power Connector Server Signal ConnectorFloppy Power Connector Server Signal ConnectorOutput Power/Currents GroundingRemote Sense 550 W Load Ratings600 W Load Ratings 650 W Load Ratings700 W Load Ratings 750 W Load RatingsFan operation in standby mode Voltage RegulationStandby Outputs 800 W Load RatingsDynamic Loading Capacitive LoadingVoltage Regulation Limits Transient Load RequirementsRipple / Noise Capacitve Loading ConditionsRipple and Noise Redundancy Hot Swap RequirementsTiming Requirements Output Voltage TimingDescription Turn On/Off Timing Recommended DescriptionTurn On/Off Timing Protection Circuits Current Limit240VA Protection Over Current ProtectionOver Temperature Protection Over Voltage ProtectionOver Voltage Limits Output VoltageControl and Indicator Functions Pson # Signal Characteristic Signal TypePwok delay PSON#Pwok Power OK Power Supply Management InterfacePwok Signal Characteristics SMBus CommunicationField Replacement Unit FRU Signals Module FRU Data Module FRU Data FormatProduct Info Area FRU Device InformationLED Indicators MultiRecord AreaField Name PS Info Field Information Definition LED Indicators Power Supply LEDsMtbf 10Agency Requirements