SSI
ERP2U Power Supply Design Guide, V2.31
If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color (yellow).
6.1.2+12V4 Baseboard Power Connector
STATUS
Required for 700W, 750W and 800W power levels
Systems that require more then 16A of +12V current to the baseboard will require this additional 2x2 power connector. This is due to the limited +12V capability of the 2x12 baseboard power connector. +12V4 will power this 2x2 connector.
Pin | Signal | 18 AWG color |
1 | COM | Black |
|
|
|
2 | COM | Black |
|
|
|
Pin | Signal | 18 AWG Color |
3 | +12 V4 | Yellow/Green Stripe |
|
|
|
4 | +12 V4 | Yellow/Green Stripe |
|
|
|
If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color (yellow
6.1.3Required Peripheral Power Connectors
Connector housing: Amp
Contact: Amp
|
| Table 9: Peripheral Power Connectors | |
Pin | Signal |
| 18 AWG Color |
1 | +12V4 |
| Yellow |
|
|
|
|
2 | COM |
| Black |
|
|
|
|
3 | COM |
| Black |
|
|
|
|
4 | +5 VDC |
| Red |
|
|
|
|
1.If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color.
6.1.4Required Floppy Power Connector
Connector housing: Amp
|
| Table 10: P9 Floppy Power Connector | |
Pin | Signal |
| 22 AWG Color |
1 | +5 VDC |
| Red |
|
|
|
|
2 | COM |
| Black |
|
|
|
|
3 | COM |
| Black |
|
|
|
|
4 | +12V4 |
| Yellow |
|
|
|
|
1.The +12V power to peripherals may be split between the second, third, or fourth +12V channel for the purpose of limiting power to less than 240VA.
-16 -