SSI America ERP2U manual 2 +12V4 Baseboard Power Connector, Required Peripheral Power Connectors

Page 16

SSI

ERP2U Power Supply Design Guide, V2.31

If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color (yellow).

6.1.2+12V4 Baseboard Power Connector

STATUS

Required for 700W, 750W and 800W power levels

Systems that require more then 16A of +12V current to the baseboard will require this additional 2x2 power connector. This is due to the limited +12V capability of the 2x12 baseboard power connector. +12V4 will power this 2x2 connector.

Pin

Signal

18 AWG color

1

COM

Black

 

 

 

2

COM

Black

 

 

 

Pin

Signal

18 AWG Color

3

+12 V4

Yellow/Green Stripe

 

 

 

4

+12 V4

Yellow/Green Stripe

 

 

 

If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color (yellow

6.1.3Required Peripheral Power Connectors

Connector housing: Amp 1-480424-0 or equivalent

Contact: Amp 61314-1 contact or equivalent

 

 

Table 9: Peripheral Power Connectors

Pin

Signal

 

18 AWG Color

1

+12V4

 

Yellow

 

 

 

 

2

COM

 

Black

 

 

 

 

3

COM

 

Black

 

 

 

 

4

+5 VDC

 

Red

 

 

 

 

1.If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color.

6.1.4Required Floppy Power Connector

Connector housing: Amp 171822-4 or equivalent

 

 

Table 10: P9 Floppy Power Connector

Pin

Signal

 

22 AWG Color

1

+5 VDC

 

Red

 

 

 

 

2

COM

 

Black

 

 

 

 

3

COM

 

Black

 

 

 

 

4

+12V4

 

Yellow

 

 

 

 

1.The +12V power to peripherals may be split between the second, third, or fourth +12V channel for the purpose of limiting power to less than 240VA.

-16 -

Image 16
Contents SSI ERP2U Power Supply Design Guide Disclaimer Contents Error! Bookmark not defined TablesFRU Device Product Information Area Purpose Conceptual OverviewDefinitions/Terms/Acronyms RequiredMechanical Overview Required OptionalTemperature Requirements Recommended Acoustic Sound Power LevelsAcoustic Requirements Airflow RequirementsAC Inlet Connector AC Input Voltage SpecificationAC Input Requirements Redundant AC InletsInput Under Voltage EfficiencyAC Line Dropout AC Input Rating AC Line Transient Specification AC Line Fuse AC Inrush AC Line Sag Transient PerformanceAC Line Surge Transient Performance AC Line Fast Transient SpecificationAC Line Surge DC Output Specification Output ConnectorsRequired Baseboard power connector P1 Baseboard Power Connector2 +12V4 Baseboard Power Connector Required Peripheral Power ConnectorsRequired Floppy Power Connector Peripheral Power ConnectorsSerial ATA Power Connector Server Signal ConnectorFloppy Power Connector Server Signal ConnectorOutput Power/Currents GroundingRemote Sense 550 W Load Ratings600 W Load Ratings 650 W Load Ratings700 W Load Ratings 750 W Load RatingsFan operation in standby mode Voltage RegulationStandby Outputs 800 W Load RatingsDynamic Loading Capacitive LoadingVoltage Regulation Limits Transient Load RequirementsCapacitve Loading Conditions Ripple / NoiseRipple and Noise Redundancy Hot Swap RequirementsOutput Voltage Timing Timing RequirementsDescription Turn On/Off Timing Recommended DescriptionTurn On/Off Timing Protection Circuits Current Limit240VA Protection Over Current ProtectionOver Temperature Protection Over Voltage ProtectionOver Voltage Limits Output VoltageControl and Indicator Functions Pson # Signal Characteristic Signal TypePwok delay PSON#Pwok Power OK Power Supply Management InterfacePwok Signal Characteristics SMBus CommunicationField Replacement Unit FRU Signals Module FRU Data Module FRU Data FormatProduct Info Area FRU Device InformationMultiRecord Area LED IndicatorsField Name PS Info Field Information Definition LED Indicators Power Supply LEDsMtbf 10Agency Requirements