Uniden UBC3500XLT Introduction, Frequency MHz Modulation Step kHz Lower Edge Upper Edge

Page 6

UB347ZH.fm Page 6 Thursday, August 31, 2006 11:57 AM

Introduction

Your Bearcat UBC3500XLT scanning receiver is a state-of- the-art scanner radio with extended frequency. You can store frequencies such as police, fire/emergency, marine, air, amateur, and other communications into the scanner. You can carry it with you wherever you go. You can use the scanner’s scroll control to quickly select channels and frequencies, and you can automatically program channels in a system using the AutoStore feature. Use your scanner to monitor:

Police and fire departments (including rescue and paramedics)

Business/Industrial radio and utilities

Marine and amateur (ham radio) bands

Air band

Railroad

The chart below identifies the scanner band numbers, the frequency range, the modulation mode and the default step size settings.

To change the band plan:

1.Maker sure the power is turned off.

2.While holding down 1, 2 or 3 (corresponding number of the band plan), turn on the scanner.

Band Plan 1

Frequency (MHz)

Modulation

Step (kHz)

 

 

Lower Edge

Upper Edge

 

 

 

 

 

 

25.0000

29.9950

FM

5

30.0000

79.9875

FM

12.5

80.0000

82.9900

FM

10

83.0000

87.2875

FM

12.5

87.3000

107.9500

FMB

50

108.0000

136.9875

AM

12.5 / 8.33

108.0000

136.9916

selectable

 

137.0000

137.9950

FM

5

138.0000

157.9875

FM

12.5

158.0000

160.5900

FM

10

160.6000

162.5875

FM

12.5

162.6000

173.9900

FM

10

174.0000

215.9500

WFM

50

216.0000

224.9950

FM

5

225.0000

399.9500

AM

50

400.0000

405.9875

FM

12.5

406.0000

439.9937

FM

6.25

440.0000

465.9950

FM

5

466.0000

469.9900

FM

10

470.0000

512.0000

FM

6.25

806.0000

960.0000

FM

12.5

1240.0000

1300.0000

FM

12.5

6

Image 6
Contents UBC3500XLT Precautions Earphone WarningContents Entering/Editing Conventional Channel Groups UB347ZH.fm Page 5 Thursday, August 31, 2006 1157 AM Introduction Frequency MHz Modulation Step kHz Lower Edge Upper EdgeIntroduction Frequency MHz Modulation Step kHz Lower EdgeFeature Highlights GeneralFeature Highlights Search Priority Using the Multifunction Scroll Control About This ManualEntering Text How the Scanner’s Controls Are Represented in This Manual Menu Program SystemEdit Name UB347ZH.fm Page 14 Thursday, August 31, 2006 1157 AM Understanding Scanning What is Scanning?What is Searching? Understanding the Scanner’s MemoryWhat is CTCSS/DCS? 023 025 026 031 032 036 043 047 Conventional Scanning Simplex OperationWhere To Get More Information Repeater OperationInformation On The Internet Included With Your Scanner Setting Up Your Scanner Using Internal BatteriesSetting Up Your Scanner Using Rechargeable Batteries Using AC Power Removing the Display StickerConnecting an Extension Speaker Connecting the AntennaConnecting an Earphone/Headphone Connecting an Optional AntennaAttaching the Belt Clip Attaching the Wrist StrapLook At The Keypad Hold Pri Look At The Display No/revUB347ZH.fm Page 29 Thursday, August 31, 2006 1157 AM Using Menu Using FuncBasic Operation Turning On the Scanner and Setting the SquelchOnce. Volume Level and a Basic OperationScanning Systems Selecting Systems to ScanSelecting System Channel Groups Locking/Unlocking SystemsHolding On a Channel Locking/Unlocking ChannelsTemporarily Holding On a System Quick-Storing ChannelsQuickly Recalling Channels Toggling Channel Alpha TagsUsing the Menu Menu Item SubmenuUsing the Menu Displaying System Information SettingsAdjusting the Key Beep Locking/Unlocking the Keypad and ScrollSettings Turning Power Save On or OffUsing the Backlight Priority ScanConnecting Your Scanner to a Personal Computer Setting the Audio AGCAdjusting the Display Contrast Initializing the Scanner’s MemoryUsing the Cloning Options Settings PC ControlMaster scanner Clone Master Press Scan Key Wired CloningWired Clone Slave scanner Clone Slave Press Scan KeyProgramming Radio Systems Programming Radio SystemsProgramming Conventional Systems Program System New SystemEntering/Editing Conventional Channel Groups Program SystemEdit Group New Group Entering/Editing Conventional Channels Edit GroupEdit Channel New Channel Editing the System Quick Key System-Level SettingsEditing the System Name Edit Sys Option Set Quick KeyProgramming/Editing Optional Settings Setting System LockoutSetting the System Hold Time Edit Sys Option Set LockoutEdit Sys Option Set Delay Time Setting the Channel Delay TimeSetting the Data Skip Edit Sys Option Set Data SkipCopying Systems Group-Level SettingsDeleting Systems Entering/Editing the Group NameSetting the Group Quick Key Deleting Groups Channel-Level SettingsSetting Group Lockout Editing the Channel NameEditing Frequencies Edit ChannelInput Frequency Setting Channel Priority Setting Channel AlertSet Alert Setting CTCSS/DCS Set LevelSet CTCSS/DCS Setting the Channel Frequency Modulation Set ModurationSetting Channel Attenuation Setting Channel LockoutSet Attenuator Delete Channel Deleting ChannelsCopying/Pasting Channels Copy ChannelEdit Channel Paste Channel Changing the step of Air Band Service SearchSearching and Storing Quick SearchCustom Search Search for Custom SearchEditing a Custom Search Range Search for Edit CustomEditing a Service Search Search for Edit ServiceAuto Search and Store Selecting a SystemSearch for Search and Store Using the Close Call Feature Using the Close Call FeatureSetting Close Call Options Close CallSelect Mode Select Beep 10/15/30/45/60 secClose Call Hits Unlocking All Frequencies Search and Close Call OptionsManaging Locked-Out Frequencies Reviewing Locked Out FrequenciesSearching for Subaudible Tones Screening Out Broadcast SourcesSearch and Close Call Options Srch/CloCall Opt Max Auto Store Setting the Maximum Auto Store ValueSetting the Modulation Type Srch/CloCall Opt Set ModulationSrch/CloCall Opt Set Attenuator Setting AttenuationSetting Data Skip Srch/CloCall Opt Set Data SkipSrch/CloCall Opt Set Delay Time Setting the Delay TimeSetting the Search Frequency Step Srch/CloCall Opt Set StepSetting Air Band Step Setting Up Tone-Out Using Tone-OutSetting Tone-Out Standby Fire Tone-Out IntroductionUsing Tone-Out UB347ZH.fm Page 78 Thursday, August 31, 2006 1157 AM General Use Care and MaintenanceCleaning LocationBirdies Troubleshooting TroubleshootingError MemorySpecifications SpecificationsUB347ZH.fm Page 84 Thursday, August 31, 2006 1157 AM Optional Accessories Initial Setting of the Menus AppendixAppendix UB347ZH.fm Page 87 Thursday, August 31, 2006 1157 AMUB347ZH.fm Page 88 Thursday, August 31, 2006 1157 AM Planning Collecting InformationPlanning System Name and Quick Key Group Name and Quick KeyFrequency-Alpha Tag-Priority CTCSS/DCSConventional System Worksheet Conventional System WorksheetDeclaration of Conformity Declaration of ConformiryUniden Corporation All rights reserved UBZZ01347ZZ0