Priority Scan

When Priority Scan is turned ON, your scanner checks the priority channel in the banks you selected every 2 seconds for activity. If a signal is present on the priority channel, your scanner monitors the channel until the transmission ends, then resumes normal scanning. You can designate one channel in each bank as a Priority Channel. By default, the first channel in each bank is the Priority Channel, but you can change this.

To activate Priority Scan (in either the Hold or Scan Mode):

1. Press PRI to select PRIORITY ON.

Note: If you have locked out the priority channel, ERROR appears when you select Priority mode.

2.Press PRI to select PRIORITY OFF to deactivate Priority Scan.

PRIORITY ON

C 010

1240.0000 FM

ERROR

PRI CH LOCKOUT

Changing the Priority Channel

You cannot eliminate the Priority Channel, but you can change it to any one of the 100 available channels in each bank.

1.Press /HOLD.

2.Select a new Priority Channel using the keypad, then press /HOLD again.

3.Press and hold PRI for 2 seconds to designate this channel as your new Priority Channel.

Two beeps indicates that the Priority Channel has been changed. The P icon appears on the display.

C 005

512.0000 FM

UHF TV 1 UNIDEN Group A

Priority Channel Plus Scan

You can scan only the Priority Channels (except for the locked out channels) in the banks you selected.

To activate Priority Channel Plus (Only in Scan mode):

Press PRI to select PRIORITY PLUS.

To deactivate Priority Channel Plus:

Press PRI to select PRIORITY ON or PRIORITY OFF on the display to deactivate Priority Channel Plus Scan.

Note: Priority or Priority Plus Scan are disabled while Search mode is selected.

32

Image 36
Contents A N N E R Page Contents Page Introduction 15kHz Offset WFM Front and Rear View VFO/SELECT PushIcon Description UBC785XLT Shortcuts Press Menu Important Notice What is Scanning? What is Searching?Terminology Feature Highlights Where to Obtain More Information Information on the InternetIncluded with Your Scanner Package Setup Connecting an AntennaMounting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting an EarphoneConnecting the Clone Cable Connecting the Tape RecorderListening Safely RememberSetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SEARCH Range6RECORD Allows you to change the brightness of the display 9BANK TAG Storing Frequencies into Channels in Menu Mode Programming001 001 855.0000 FM010 512.0000 FM C10000000.0000 001 855.0000 NFM Alpha TAG Transfer FrequenciesStoring Alpha Tags Beep Alert Programming TipsAssigning the Beep Alert to a Channel Scan Hold Feature To directly access a specific channelScanning BankRF Attenuation Feature Setting the Delay Mode for FrequencyLockout in Hold Mode 001 141.5000 FM Uniden Group aChannel Lockout Lockout in Scanning Mode Restoring a Locked-out ChannelRestoring All Locked-out Channels 010 1240.0000 FM 005 512.0000 FMPriority Scan Changing the Priority ChannelSetting a Search Range SearchingSrch 12.5k Search Hold Feature Srch 12.5k 1240.0000 FM Range 25cm Amateur GrpStarting Chain Search Data SkipSrch 12.5k 1240.0000 NFM Range C004 Frequency SkipStoring Search Frequencies Squelch SQ Mode 12--56001 FM Bank Auto StoringFor Search mode, select 1SERVICE Option / Chain Search 003 001 FM DCS Bank003 FM DCS Uniden Group a 001 512.0000 FM BankAir Service Search Using Aircraft Service SearchAir Service Search Skip Changing the stepPC Control Mode Remote InterfaceTo connect Scanner to PC To program your scannerClone Mode Start Remote Mode and Change Transfer SpeedSpeed 39600 bps 419200 bps PC Control ParameterTo connect the Scanner to Scanner Clone Master Unit Slave Unit Additional Features DimmerEnter Lock Key Beep OptionReverse Mode Receiving Mode SelectionFrequency and Channel Tuning with the VFO Control Channel Step SelectionCare and Maintenance Troubleshooting Resetting the ScannerSpecifications Glossary of Terms Page Ctcss Frequency List Hz DCS Tone CodeUBC785XLT Flow Charts Scan Option System Option Dimmer 1HIGH / 2MEDIUM / 3OFF Screen Mask Declaration of Conformity Uniden Corporation All rights reserved UBZZ01343ZZ0
Related manuals
Manual 60 pages 53.46 Kb

UBC785XLT specifications

The Uniden UBC785XLT is a versatile and powerful handheld scanner designed for both amateur radio enthusiasts and professional users. Renowned for its broad frequency coverage, this scanner offers a comprehensive solution for monitoring a wide array of communications. Combining advanced features with exceptional ease of use, the UBC785XLT is an essential tool for anyone interested in scanning radio frequencies.

One of the key features of the UBC785XLT is its extensive frequency range, which spans from 25 MHz to 1.3 GHz. This allows users to listen in on various signals, including VHF and UHF bands, making it suitable for public service channels, aircraft communications, and even amateur radio operations. It also supports a variety of modes, including FM, AM, and digital modes, allowing users to access a wide array of broadcasts.

The scanner’s memory capacity is another notable characteristic. It comes with 1,000 channels grouped into 50 banks, allowing you to organize your frequencies efficiently. Users can easily program and store their favorite channels, and the scanner features a built-in memory backup to preserve settings and frequencies even when powered off.

Incorporating advanced scanning technologies, the UBC785XLT features a triple conversion superheterodyne design, which enhances its frequency stability and adds to the overall sensitivity. The scanner also comes equipped with Close Call RF Capture technology, which enables it to automatically find and monitor nearby signals in real-time, making it easier for users to discover new frequencies.

For those who prefer customized settings, the UBC785XLT offers a range of programmable features, including priority scanning, which allows users to designate specific channels to be monitored more frequently. The scanner’s versatile scanning modes, such as Dynamic Memory Allocation, make it easy to tailor the experience based on individual needs, ensuring that important communications are never missed.

The UBC785XLT is designed with user accessibility in mind. It features a large, backlit LCD display for easy readability in various lighting conditions. The user interface is intuitive, making navigation through channels and settings straightforward.

In summary, the Uniden UBC785XLT is a comprehensive scanning solution that appeals to a wide range of users. With its extensive frequency coverage, advanced scanning technologies, and user-friendly interface, it stands out as a top choice for anyone looking to explore the world of radio communications. Whether for emergency services monitoring or personal interest in radio messages, the UBC785XLT delivers reliable performance and versatility.