Status LEDs
Each time NetworKam starts, it will perform a Power-On Self Test, abbreviated as POST hereafter, to examine every hardware module. As soon as the administrator plugs in the power adapter, both LEDs under the network LED will flash one by one until the POST is done. If any module fails, both LEDs will indicate to the users the error according to the pattern listed in Appendix A. If the result is good, both LEDs will turn off for a while and then follows the pattern below. Network interface depends on the peripherals including Ethernet UTP cable, modem or null modem cable. If the Ethernet cable between NetworKam and Ethernet hub is good, NetworKam will choose the Ethernet network. If Ethernet is unavailable but a operational modem is connected, the network interface will be PPP with modem. If either of the above is not the case, NetworKam will try the interface of PPP with null modem.
Network Interface | Condition | LED2 (Heartbeat) | LED3 (Status) |
| | | |
Ethernet | before installed | OFF | OFF |
| | | |
| after installed | flash | OFF |
| | | |
| during camera control | flash | Flash |
| | | |
PPP with modem | after POST | flash | ON |
| | | |
PPP with null modem | before connected | ON | ON |
| | | |
| after connected | flash | ON |
| | | |
10
www.vivotek.com
T: 886-2-22404099
F: 886-2-22404097