Power Amplifiers

The digital power amplifiers used in QLight™ DP series loudspeakers are conservatively rated and designed with sufficient headroom to handle large signal transients without break-up or distortion. Each channel of the module will deliver 800 watts r.m.s. into an 8 ohm load.

AC Power Requirements

QLight™ DP series loudspeakers are equipped with Neutrik PowerCon® AC mains connectors which mate with the power cord supplied with your unit. They operate with mains voltages in the range from 100 to 240 volts. When connected to a mains supply the digital power amplifier modules will automatically detect the mains supply present. The mains fuse is a 10A 20mm 230V anti-surge type for all mains supplies. Should it be necessary always replace the fuse with the identical size and type.

Cooling

The Class D amplifiers are among the most efficient in their class, with operating efficiencies greater than 90%. Conventional heatsinks are not required to cool the amplifiers; they are cooled by the action of convection from the panel of the amplifier module at the rear of the enclosure. It is important to leave space around and especially above the rear panel to allow the convection of heat away from the loudspeaker. This cooling effect is sufficient to maintain the amplifiers within a normal operating temperature range.

In an ambient temperature of 25º C the rear panel of the unit can reach temperatures of 55º C and will feel warm to the touch. This is perfectly acceptable and is considered normal operation.

Audio Input

The signal inputs are fully balanced, with an input impedance of 10kΩ. The female input XLR connector is wired pin 2 hot (+ve), pin 3 cold (-ve), and pin 1 screen (shield). The male link XLR connector is wired pin 2 hot (+ve), pin 3 cold (-ve), and pin 1 not connected. Multiple self-powered enclosures may be driven from a single audio console, up to a practical limit of 16 units. A greater number may cause unacceptable signal loss due to the loading of the console output.

QLight DP series manual page 17

Image 17
Contents TQ-308DP TQ-310DP TQ-315DP TQ-445DP TQ-425DP TQ-115DP Qlight DP Digital Power SeriesQLight DP series QLight DP series QLight DP series Important Safety Information Important Safety Information Unpacking the TQ series loudspeaker IntroductionThanks Features Product Range Summary TQ-308DP self-powered two-way loudspeakerTQ-310DP self-powered two-way loudspeaker Limit HI TQ-308DP and TQ-310DP connector panel functionsTQ-445DP self-powered three-way loudspeaker TQ-315DP self-powered two way loudspeakerTQ-315DP and TQ-445DP connector panel functions TQ-115DP self-powered subwoofer TQ-425DP self-powered subwoofer TQ-425DP connector panel functions Limit HI TQ-115DP connector panel functionsSystem requirements TQ-308DP, TQ-310DP and TQ-315DP System RequirementsSystem requirements TQ-445DP System requirements TQ-425DP and TQ-115DPAC Power Requirements Power AmplifiersAmplifier Modules CoolingLimit LED Functions Limiting FunctionsEqualisation Mode a / Mode B switchUpdating firmware or loudspeaker parameters Converging Elliptical Waveguides Rigging Hardware Mounting and FixingQLight DP series QLight DP series Choosing the best location Permanent InstallationsQLight DP series Removal of the 12/1 driver TQ-445DP Removal of the HF unit TQ-308DP, TQ-310DPRemoval of the low frequency driver TQ-115DP Removal of the midrange unit TQ-445DPRemoval of the low frequency driver TQ-425DP Removal of the amplifier module all models Flying accessories Appendix a Spares and AccessoriesAppendix B Technical Specifications QLight DP series Limited Warranty Appendix C WarrantyWarranty Coverage ShippingIncidental and consequential damages