Vista LM104-P50 manual Module Setup, Important Note

Page 4

Module Setup

IMPORTANT NOTE!

The LM104-P50 module gets all of its electrical power through the PC/104 bus connector. The module requires +5Vdc, ±10% at 420mA. Because it was designed specifically for the PC/104 bus, the module does not support any external power supply, nor is it designed to run at any other supply voltage. Operating an LM104-P50 module at a supply voltage higher than +5Vdc will probably damage the module and will definitely void the warranty. A supply below 4.65Vdc will not damage the module, but it will not function, because the supervisory circuit will force the Neuron into RESET and hold it there.

Before installing the LM105-P50, check the host system for the availability of interrupt request lines (IRQs) and free I/O address locations. Most problems with configuring the LM104-P50 can be traced to conflicts between the LM104-P50 and some other device in the system. The software driver will work with any combination of I/O address and IRQ that is not shared with any other device. Note that more than one LM104-P50 may be installed in the same host system, provided each module has its own address and IRQ. Please see page 3 for jumper settings and page 5 for software driver installation details.

The LM105-P50 (Option 1/2/3/6) installs like any other PC/104 board. It has a 16-bit stackthrough connector, so other PC/104 boards may be installed above or below it in the stack, using 0.6” (15mm) spacers to maintain proper distance between cards. Note that Option 5/5C boards do not allow boards to be installed above them, as the Echelon PLT-22 transceiver is too tall. Option 5/5C boards must be installed at the top of a stack.

Before plugging the PC/104 boards together, double check to insure that the boards are aligned properly, and that the PC/104 connectors between boards are not off by one position.

2

Image 4
Contents LM104-P50 Table of Contents Product Overview LM104-P50 Network Interface OptionsModule Setup Important NoteJumper Settings JP1 ServiceJP5 IRQ Select Software Driver Installation Device = Drive \PATH\ LM104INT.SYS SwitchesDEVICE=C\LON\LM104INT.SYS /D1 /P1 /Q5 Cable Wiring and Termination Cable Grounding and TerminationCable Grounding Option 1 RS-485Options 2 and 3 Twisted pair transceivers Termination of an LM104-P50-1 RS-485 network nodeOption 5 Power line carrier transceivers Option 6 Free Topology TransceiverTroubleshooting User Connectors Appendix aMechanical EnvironmentalAppendix B J1/P1 J2/P2 Number Row a Row B Row C Row DAppendix C No Connection NETAppendix D IRQ SelectWindy City Wire ConnectAir International Eastman Wire & CableAppendix E Appendix F Concerning Conformal CoatingsPC/104 Specification, Version Echelon literature Appendix GStandard Warranty Service Appendix HWarranties Exclusive Limitation of Liability