FEATURES

Fan also will automatically turn on. Overheating may result when the inverter is being operated at levels exceeding its wattage rating or because it has been placed in a location or in an manner which prevents proper heat dissipation. After approximately 15 minutes, the High Temperature Indicator light and the Cooling Fan will turn off and the inverter will automatically restart indicating that the inverter temperature has dropped to a safe operating level.

Over Load LED Indicator Light. This light will turn RED and the inverter will automatically shut down when the continuous power draw from the inverter exceeds the maximum continuous power rating for the inverter. Turn the inverter OFF (O), determine and resolve the cause of the overload prior to resuming operation of the equipment or appliance. Turning the inverter ON (I) will reset it.

c).Remote Operation Jack.

The inverter is designed to be operated from a remote location via the WHISTLER PP015DC Remote Control Switch which plugs into this socket. This optional accessory is available through WHISTLER or your WHISTLER dealer.

i

2000 watt series shown

j

FEATURES

d). Wattage & Voltage

Wattage Indicator. This illuminated Digital display moni- tors the wattage being consumed by the inverter.

When the reading rises above the rated limits, the inverter may automatically shut down. In this event, it is likely that the draw of the equipment or appliance being operated is greater than the battery is capable of producing.

Voltage Indicator. This Digital display monitors the voltage being drawn from the battery by the inverter. The voltage is measured at the Negative and Positive power input terminals on the inverter. The voltage level reading will be lower than the battery voltage due to the voltage "drop" that occurs as the battery voltage runs through the terminal connections and cables.

The inverter is designed to operate with input voltages ranging from 10 to 15 volts. When the voltage drops below

10.5volts DC an audible alarm will sound. If the voltage drops below 10 volts DC, the voltage indicator will go out and the inverter will automatically shut down. The inverter also will shut down automatically when the input voltage exceeds 15 volts DC. Despite this "built in" protection, the inverter may be damaged if the input voltage exceeds 15 volts DC and damage caused by excess voltage input is not covered under the WHISTLER warranty.

Note: In the event of automatic shut down or continuous audible alarm, turn the inverter OFF (O) until the source of the related problem has been determined and resolved.

4

5

Image 4
Contents Watt Series Hours Monday Friday Am 500 pm CT IntroductionTable of Contents Whistler FeaturesRemote Operation Jack FeaturesWattage & Voltage Standard North American 110 AC Outlets are provided Inverter Information Important InformationGetting Started Selecting the Optimum Power Source Don’t Push ItBattery Information BATTERY/CABLE InformationWire Cable Gauges 1200Cable Information Operation2000 Making the ConnectionThis ground can’t be the same ground as the AC ground Power Source Important Information on Battery ChargersFor You Television Fans & Audiophiles For You Microwave Chefs Some Powerful Advice For You Technical Types Operating PrincipalsModified sine wave produced by Your Whistler Inverter Operation Summary Operating PRINCIPALS/SUMMARYTrue sine wave typical of home AC outlet Review Troubleshooting Specification Overload or High Temp LED on Problem SolutionWarranty Consumer WarrantyService Under Warranty Service Out Of WarrantyWarranty Memo Customer Service