•Avoid placing the inverter near sources of heat or in direct sunlight.
•When in use, make certain that the inverter is properly ventilated.
•Do not use the inverter near flammable materials, fumes, or gases.
•Always operate the inverter in accordance with the instructions in this manual. Failure to do so may result in property damage, personal injury, or loss of life.
•While connecting the inverter to the power source, make certain that the inverter is well removed from any potential source of flammable fumes or gases.
•Always ground the inverter before operating it.
•In the event a continuous audible alarm or automatic shut off, turn the inverter OFF immediately. Do not restart the inverter until the source of the problem has been identified and corrected.
| TROUBLESHOOTING | ||
|
|
|
|
| PROBLEM: TV Interference | ||
|
|
|
|
| Problem | Solution |
|
| Electrical interference from | Add a Ferrite data line fil- |
|
| ter inverter. | on to the TV power cord. |
|
|
| This filter is available at |
|
|
| RadioShack, or other |
|
|
| electronic supply stores. |
|
|
| part number |
|
|
|
|
|
| PROBLEM: Low or | No Output Voltage |
|
| Problem | Solution |
|
| Using incorrect type of | Use true RMS reading meter |
|
| voltmeter to test output | See "For You Technical |
|
| voltage. | Types" |
|
|
| Section of this manual. |
|
|
|
|
|
| PROBLEM: Low Battery Alarm On All The Time | ||
| Problem | Solution |
|
| Input voltage below | Keep input voltage above |
|
| 11 volts. | 11 volts to maintain |
|
|
| regulation. |
|
| Poor or weak battery | Replace battery. |
|
| condition. |
|
|
| Inadequate power being | Use lower gauge wire. See |
|
| delivered to the inverter | “Wire Cable Gauges” |
|
| or excessive voltage drop. | section of this manual. |
|
|
| Keep wire length as short |
|
|
| as possible. |
|
|
|
|
|