Important Safeguards (Continued)

The following two labels are located on the upper and lower taping heads. Replacement part numbers for these labels are listed below each label.

The "Warning-Sharp Knife" label warns operators and service personnel of the extremely sharp knife used to cut the tape at the end of the box sealing operation. The label, shown in Figure 1-11, is located on the orange knife guard between the applying roller assembly and the buffing roller assembly. Never operate taping heads with knife guard removed.

Before working with the taping heads or loading/ threading tape, refer to Figures 3-1 and 3-2 in Section II to identify the knife location. Keep hands out of these areas except as necessary to service the upper taping heads or to load/thread tape.

The "Tape Threading Label", shown in

Figure 1-12,is attached to the left side of both the upper and lower taping heads. This label provides a convenient tape threading diagram. More detailed tape loading and threading information is provided in this manual in the set-up procedure section.

Figure 1-12 – Tape Threading Label

Figure 1-11 – Knife Warning Label

6

Image 11
Contents 3M-Matic To Our Customers Replacement Parts and Additional ManualsTo Our Customers Table of Contents Section II AccuGlide II STD 3-Inch Taping Head 3M-MaticTM800r3 Random Case Sealer, Type Intended Use800r3 Contents Knife Warning Label Important SafeguardsOperating Notice Label 10 -Air Pressure Gage Label 11 Knife Warning Label 12 Tape Threading LabelSpecifications Box Size Box Weight and Size Capacities WeightMaximum Machine Dimensions MinimumUncrated Installation and Set-UpReceiving And Handling BOX Size Capacity of Case Sealer Pneumatic Connection Case Sealer Components OperationMain Air On/Off Valve/Pressure Regulator/ Filter Figure Controls, Valves and Switches Electrical On/Off SwitchAir Pressure Gauge, Upper Taping Head Frame DoorAir Pressure Regulator, Box Drive Belt Centering -4 Box Exit Cams Main Air Pressure GaugeLatching Knob, Upper Taping Head Frame -Figure See Section II, pages 7 Operation Box SealingLubrication MaintenanceBox Drive Belt Left Side View Infeed End Box Drive Assembly, Infeed End Personnel could result Circuit Breaker Knife Replacement, Taping HeadPersonnel could result Drive Belt Tension AdjustmentsTaping Head Adjustments Refer to Section Special Set-Up Procedure Column Re-Positioning This page is Blank Troubleshooting Guide Problem Cause Correction TroubleshootingTroubleshooting 800r3 Case Sealer Operating Sequence Electrical Diagram Electrical/Pneumatic DiagramsPage Pneumatic Diagram Page This page is Blank Parts and Service Information Part Number Option/Accessory Options/AccessoriesReplacement Parts Illustrations and Parts Lists This page is Blank 800r3 Random Case Sealer Frame Assemblies 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Ref. No 3M Part No Description 800r3 Random Case Sealer Safety and Information Labels Ref. No 3M Part No Description Qty 800r3 Safety and Information Labels

800r3 specifications

The 3M 800R3 is a cutting-edge respiratory protection system designed for those who work in environments where they may encounter hazardous airborne contaminants. This respiratory mask is part of 3M’s extensive line of personal protective equipment and is engineered for comfort, performance, and reliability.

One of the main features of the 3M 800R3 is its advanced filter technology, which ensures effective filtration of organic vapors and particulates. It is equipped with a P100 filter, which provides a minimum efficiency of 99.97% against airborne particles, making it ideal for use in various industries, including construction, healthcare, and chemical processing. This level of protection is essential for workers who need to protect their respiratory systems from harmful substances.

The 3M 800R3 employs a unique multi-layered filtration system. This includes an activated carbon layer that absorbs certain gases and vapors, providing an added level of safety. This technology enhances the overall user experience by reducing the inhalation of noxious chemicals, thereby ensuring better worker health and increasing productivity.

Comfort and fit are paramount in any respiratory protective system, and the 3M 800R3 does not disappoint. The mask features an ergonomic design with adjustable straps, allowing users to achieve a secure and comfortable fit. Its lightweight material reduces fatigue during extended wear, making it suitable for long shifts in demanding environments. Additionally, the flexible facepiece conforms to various face shapes, ensuring a good seal without compromising comfort.

Another notable characteristic of the 3M 800R3 is its versatility. It can be used with a range of cartridges and filters, allowing users to customize their level of protection based on specific job requirements. This adaptability makes it an excellent choice for workers who face different hazards throughout their workday.

The 3M 800R3 is also designed for easy maintenance and cleaning. Its washable components ensure longevity and hygiene, while the replaceable filters reduce waste and operating costs, making it an economical choice for employers and safety professionals.