■FRONT PANEL
AC IN |
|
| LAMP AC OUT |
OPTION SW OPTION SW | LAMP | DC 15V | |
CONTROL OUT CONTROL IN | CONTROL | OUT | |
OP | C S | + | − |
100V 500W
tAC 120V Inlet [AC IN](AC 3P Inlet) Connect the supplied AC cable.
yOption Switch Terminal (OPTION SW CONTROL OUT) (2P Terminal Board)
A relay switch capable of controlling the contact to short or open from a Control Panel
uOption Switch Control Input Terminal (OPTION SW CONTROL IN) (1P Terminal Board)
Connect it to OP Output Terminal on the pan/tilt head when controlling OPTION SW CONTROL OUT Terminal
yto short or open, using a cable (to be locally pur- chased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum allowable cable length is 30 meters.
Applicable Wire
Solid wire: | ø1.02 (AWG 18) | |
Stranded wire: | 0.75 mm2 | |
Usable wire range |
|
|
Solid wire: | ø0.64 to ø1.02 | |
| (AWG 22 to 18) | |
Stranded wire: | 0.3 mm2 to 0.75 mm2 | |
| (AWG 22 to 20) | |
| Strand diameter: ø0.18 or more | |
Standard bare end length | 10 mm |