CONNECTION
•Switch off all the devices before making any connec- tion.
•Use the Pan/tilt Head
•Connect the DC 15V OUT Terminals [+] and
Applicable (usable) wire
Solid wire: | ø1.29 (AWG 16) | |
Stranded wire: | 1.25mm2 (AWG 16) | |
| Strand diameter ø0.18 or more | |
Standard bare end length: | 11 mm |
•To switch on and off the halogen lamp from the control panel, connect the LAMP CONTROL Input Terminals
[C]and [S] to the LAMP CONTROL Output Terminals
[C]and [S] on the pan/tilt head respectively with cables (to be locally purchased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum allowable cable length is 30 meters. Locally purchase an AC plug conversion cable that matches the AC plug for the halogen lamp to be used, and connect a halogen lamp of 250 W to 500 W to the lamp AC outlet. If a halogen lamp of less than 250 W is connected, the LAMP Indicator on the control panel may flash to indicate a burnt bulb even though the lamp is normal.
Applicable wire |
|
|
Solid wire: | ø1.29 (AWG 16) | |
Stranded wire: | 1.25 mm(AWG16)2 | |
Usable wire range |
|
|
Solid wire: | ø0.64 to 1.29 (AWG 22 to 16) | |
Stranded wire: | 0.3 mm2 to 1.25 mm2 | |
| (AWG 22 to 16) | |
| Strand diameter ø0.18 or more | |
Standard bare end length: | 11 mm |
•To control the option switch terminal to short or open from the control panel, connect the OPTION SW CON- TROL IN Terminal [OP] on the adapter to the OP Output Terminal on the pan/tilt head with a cable (to be locally purchased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum capacity of the option switch terminal is 120V 1A (AC/DC).
Applicable wire |
|
|
Solid wire: | ø1.02 (AWG 18) | |
Stranded wire: | 0.75 mm2 | |
Usable wire range |
|
|
Solid wire: | ø0.64 to 1.02 (AWG 22 to 18) | |
Stranded wire: | 0.3 mm2 to 0.75 mm2 | |
| (AWG 22 to 20) | |
| Strand diameter ø0.18 or more | |
Standard bare end length: | 10 mm |
•For details on the connection, refer to the Operating Instructions.