iLamp Control Input Terminals (LAMP CONTROL C/S) (2P Terminal Board)
Connect it to LAMP CONTROL C/S Terminals on the pan/tilt head when controlling the halogen lamp con- nected to LAMP AC OUT Connector !0to switch it on and off, using a cable (to be locally purchased) with a nominal cross section of 0.3 mm2 or more that meets the UL specifications. The maximum allowable cable
length is 30 meters. |
|
|
Applicable wire |
|
|
Solid wire: | ø1.29 (AWG 16) | |
Stranded wire: | 1.25 mm2 (AWG 16) | |
Usable wire range |
|
|
Solid wire: | ø0.64 to ø1.29 | |
| (AWG 22 to 16) | |
Stranded wire: | 0.3 mm2 to 1.25 mm2 | |
| (AWG 22 to 16) | |
| Strand diameter ø0.18 or more | |
Standard bare end length | 11 mm |
oDC 15V Output Terminal (DC 15V OUT +/–)
(2P Terminal Board)
Connect it to (DC 15V IN +/– Terminals) on the pan/tilt head with a cable (to be locally purchased) with a nom- inal cross section of 1.25 mm2 or more that meets the UL specifications. The maximum allowable cable length is 30 meters.
Applicable (usable) wire |
| |
Solid wire: | ø1.29 (AWG 16) | |
Stranded wire: | 1.25 mm2 (AWG 16) | |
| Strand diameter ø0.18 or more | |
Standard bare end length | 11 mm |
!0Lamp AC Output Connector [LAMP AC OUT] (AC 3P Outlet)
AC Output Connector for halogen lamps to be switched on and off from a Control Panel