HOW TO USE EXTERNAL

CONTROL

ABOUT EXTERNAL CONTROL

The Multi-Format Monitor has two external control terminals.

One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger contact) method selected in the function setting.

MAKE (make contact system): Controls the function by stable disconnection (terminal open) or short-circuiting (short with GND of 15th terminal) of the controlled terminal.

TRG. (trigger system) : Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th terminal) the controlled terminal.

*MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu.

*The 14th terminal (REMOTE ENABLE) is always controlled by the make contact system regardless of the REMOTE SYSTEM

setting.

The other terminal used for remote control is the RS-232C terminal. This allows the monitor to be controlled by a PC via serial communication.

NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2RS-232C terminal > 3 front panel buttons. When trigger contact is on, the front panel buttons can be operated.

 HOW TO USE THE MAKE/TRIGGER TERMINAL 10 9

8

7 6

Connections

 

 

 

5 4 3 2 1

 

 

 

 

 

 

Connect (short-circuit) the 15th terminal (GND) to each of the 1st through 14th terminals in the 3-line

 

 

15-pin D-sub connector. The functions of each terminal are listed below.

 

 

 

The Names and Functions of Terminals

 

15 14 13 12 11

 

 

 

 

 

 

No.

Names

Functions

Operations (OFF p[ ON)

 

*1

1

TALLY

Puts on the tally lamp.

Put off

Put on

 

 

 

 

 

 

 

 

 

2

INPUT A

Changes the input to INPUT A

Not change

Change

 

 

 

 

 

 

 

 

 

3

INPUT B

Changes the input to INPUT B

Not change

Change

 

 

4

INPUT C

Changes the input to INPUT C

Not change

Change

 

 

 

 

 

 

 

 

 

5

INPUT D

Changes the input to INPUT D

Not change

Change

 

 

6

INPUT E

Changes the input to INPUT E

Not change

Change

 

 

 

 

 

 

 

 

 

7

INPUT F

Changes the input to INPUT F

Not change

Change

 

 

 

 

 

 

 

 

 

8

COLOR OFF

Changes the picture black-and-white.

Not change

Change

 

 

9

AREA MARKER

Displays the area marker.

Not display

Display

 

 

 

 

 

 

 

 

 

10

ASPECT

Changes the screen ratio to 16:9

4:3

16:9

 

 

11

TALLY SELECT

Switch the tally lamp color.

GREEN

RED

 

 

 

 

 

 

 

 

12

MARKER

Selects the type of the area marker

Selection in the main unit

Selection in the remote

*2

 

 

 

 

control

 

 

13

STATUS

Displays the monitor’s status

Display

 

 

*3

 

 

 

 

 

 

 

14

REMOTE ENABLE

Makes the external control form the

Invalid

Valid

 

*4

 

 

MAKE terminal valid or invalid

 

 

 

 

15

GND

Used as a ground terminal

 

 

 

 

 

 

 

 

 

*1 : OFF stands for disconnection, and ON stands for short-circuit.

When trigger contact is on, the setting switches between ON and OFF every time the terminal is short-circuited. (Only TALLY is controlled by being OFF(disconnection) and ON(short-circuit).)

*2 : Selects the area marker size from AREA MARKER (setting on the main unit) or AREA MARKER-R (setting on the remote control) setting.

*3 : The STATUS function is activated when the connection to the STATUS terminal is changed (ON to OFF, or OFF to ON). The monitor’s status is displayed for 3 seconds.

*4 : Setting REMOTE ENABLE to ON enables remote control. (same for both MAKE/TRIGGER methods.)

Operation

1.Set REMOTE ENABLE to ON.

2.Short-circuit or disconnect the desired terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)

Changing the Signal Input

1.Set REMOTE ENABLE to ON.

2.Short-circuit the desired INPUT terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)

3.Disconnect the INPUT terminal selected above. The signal input is actually changed after the disconnection has been completed.

NOTES: • When more than two terminals are selected (short-circuited) from INPUT A through INPUT F, the signal input is not changed.

To control INPUT A through INPUT F, we recommend using the interlock switch, which turns off a switch when another switch is turned on.

When trigger contact is on, and if several terminals are short-circuited simultaneously, proper control cannot be done. It is always necessary to short-circuit one terminal for one operation. Also, use of the Tact Switch is recommended.

ENGLISH

19

Image 21
Contents Operating Instructions Page BT-H1700AE Cable Length EMC SupplementFor U.K. only How to replace the fuseFront View Controls and FeaturesREAR/SIDE View  Video Input Card Optional BT-YA701P  COMPONENT/RGB Input Card OptionalInput Card Optional  SDI Input Card Optional BT-YA703P Input terminals for component serial digital signals HD SDI Input Card Optional BT-YA705G Connection terminal to a Multi-Format Installing the Input Card Preparation Attaching the Wide Mask  Attaching the Power Cord Holder Basic Menu Operations  Main Menu Items HOW to USE Main Menu Main Menu Screens Items Functions Displays Item Contents and Adjustment RANGE/SETTINGS HOW to USE Main Menu contdArea MARKER-R Center MarkerColor Matrix  Setup Menu Items HOW to USE Setup Menu Setup Menu Screens Items FunctionsPicture SUB ADJ Function SettingColor TEMP./BAL Distortion ADJ SIZE/POSI. ADJStatus Display All resetControl Lock OFF/ONHOW to USE External Control  HOW to USE the MAKE/TRIGGER Terminal 10 about External Control  HOW to USE the RS-232C Terminal HOW to USE ExternalCommunications Specifications CommandsIndications TroubleshootingFollowing are not malfunctions When black vertical lines appear on the screenSLOT3  SELF-CHECK IndicationsSpecifications  Compliant Signal Formats of Each Input Card Input SignalsEmbedded Audio Weight Power consumption 14 V DC, 0.25 aDimensions H x D Power consumptionVQT0A55-1 PN-Y-U-VP LCT1261-001B