Panasonic PT-AE3000E manual Care and Replacement Removing and replacing the lamp unit

Page 48

Care and Replacement

Removing and replacing the lamp unit

1.Use a Phillips screw driver to loosen the 3 lamp unit fixing screws until the screws turn freely.

Lamp unit fixing screws

Lamp unit lock

2.Hold the handle of the lamp unit and release the lamp unit lock.

3.Pull out the lamp unit gently from the projector.

4.Replace the new lamp unit while making sure that the direction of insertion is correct.

Press the top of the lamp unit and make sure the unit is installed securely.

Press here

Press here

5.Tighten the lamp unit fixing screws securely with a Phillips screwdriver.

Attaching the top cover

1.Attach the hinge parts of the top cover to the projector and press slightly until it clicks.

When the projector is mounted on the ceiling, attaching the hinge parts is not required.

2. Hook the top cover safety hook to the projector.

3.Hooking the tabs of the top cover to the front of the projector and lift down slowly.

4. Press the back corner of the top cover gently until

it clicks.

 

Make sure to hook the top cover safety hook to the

Top cover safety hook Hinge part

body.

Maintenance

NOTE:

Be sure to install the lamp unit and the top cover of the projector securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

Grip the handle and keep the lamp unit paralleled when you remove the lamp unit.

Do not switch the power on while the top cover is opened.

When the projector is mounted on the ceiling, keep the lamp unit paralleled up and remove.

Resetting the LAMP RUNTIME

 

If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the

 

projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure

 

should thus be completed within 10 minutes.

6.

Press and hold the ENTER button for

1.

Connect the mains lead to the projector and a

 

mains socket, and switch the MAIN POWER on.

 

approximately 3 seconds.

2.

Switch the power button.

 

 

 

 

7.

The confirmation screen will be displayed and

3.

Press the MENU button to display the menu.

 

select OK.

4.

Press F G to select OPTION and press ENTER.

8.

Switch off the power button to reset the duration of

5.

Press F G to select LAMP RUNTIME.

 

the LAMP RUNTIME.

 

 

 

 

 

 

 

 

9.

Confirm the duration of time in LAMP RUNTIME is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reset to "0".

 

 

 

 

 

 

 

 

 

 

 

 

LAMP POWER

 

 

 

 

 

 

 

 

STANDARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LAMP RUNTIME

1820H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48 - ENGLISH

Image 48
Contents Operating Instructions Important Safety Notice For business users in the European UnionThis Apparatus Must be Earthed To rain or moistureImportant Safety Notice Important the Moulded Plug U.K. onlyContents Contents Menu NavigationPicture menu Lens ControlPrecautions with regard to safety Precautions with regard to safety Do not set up the projector outdoorsDo not look into the lens while the projector is being used Remove the used batteries from the remote control promptly Do not put your weight on this projectorUse only the specified batteries Do not mix old and new batteriesProjector may be subject to electromagnetic interference Order to get the best picture qualityDo not touch the surfaces of the lens with your bare hands Liquid crystal panelAccessories Remote control for Safety cable Lens coverPT-AE3000E TTRA0141 Mains lead for UKRemote control About Your ProjectorProjector body About Your ProjectorTop and front view About Your Projector Back and bottom view ComputerHdmi ComponentSetting up Calculation methods for screen dimensionsScreen size and throw distance Front leg adjusters and throwing angle Setting upProjection method Mounting on the ceiling and projecting from frontAdjusting the lens shift dials Lens shift and positioningHorizontal shift Vertical shiftSetting up Projector location range When the screen position is fixedWhen the projector position is fixed 100% 40%Before connecting to the projector Connecting example Component IN/S-VIDEOConnecting example Hdmi IN/COMPUTER ConnectionsSwitching the projector on/off ConnectingMains lead Connect the mains lead to a mains socketPower indicator Switching the projector on/offPower indicator informs you the status of the power Switching on the projector Switching off the projectorPress I to select OK and press the power or Enter button Selecting the input signal Switch on the connected devicesAdjust the focus and the projected image size Projecting an imageRemote control operation Managing the lens control settingsSwitching the picture mode Adjusting the imageLoading a saved setting Switching the aspect ratioAdjusting the signal condition with a waveform Remote control operationAdjustment example Adjusting with luminance optionsAdjusting with RGB options Contrast G/CONTRAST BSetting your own colour profile Adjusting the selected colourCreate a new profile Managing stored logsSaving a log setting as a profile Deleting the saved profilesChanging the profile names Loading saved profilesResetting to the factory default settings Switching the input signalUsing the assigned function as shortcut Capturing an imageAdjusting with the bar scale items Menu NavigationNavigating through the Menu Displaying the main menuMain menu and sub-menu Menu NavigationLanguage Lens Control Picture menu Colour Temperature Split AdjustDynamic Iris Waveform MonitorAdjusting the image in a split window NR Noise ReductionColour Signal Mode Memory SaveMemory Load Memory EditClock Phase Position menuPosition DOT ClockComponent signals Position menu Aspect ratio options and projection exampleZoom FITAuto Setup WSSOver Scan KeystoneAdjust ZOOM/FOCUS, H-AREA Position ZOOM/FOCUSLens Memory Load Lens Memory SaveYou can edit named lens memory settings Rename the lens memory settingLens Memory Edit Underlined item is factory default setting ButtonBlank function Assignable functionsOption menu Installation High Altitude ModeLamp Power SleepTemp and Lamp Indicators Managing the indicated problemsLamp indicator Temp indicatorCare and Replacement Cleaning the projectorCare and Replacement When to replace the lamp unitReplacing the lamp unit Before replacing the lamp unitCare and Replacement Removing and replacing the lamp unit Resetting the Lamp RuntimeAttaching the top cover Troubleshooting List of compatible signals Technical InformationQuality *2 Dots *1 MHz KHzSerial terminal Technical Information Communication settings Control commandsInquiry commands Specifications Video ComputerComponent HdmiCeiling mount bracket safeguards Installing the safety cableLoop twice Loop once Dimensions Trademark acknowledgementsUnit mm Index Indicator status Remote control button IndexMain menu Control panel button