Panasonic PT-AE1000U manual Wss, Over Scan, Keystone, Auto Setup, Aspect ratio depend on signals

Page 36

Settings

POSITION Menu

Aspect ratio depend on signals

Press I H to cycle through the aspect ratio options. The cycle pattern depends on the connected signals.

 

4:3 \ 16:9 \ 14:9 \ JUST \

VIDEO/

ZOOM1 \ ZOOM2

AUTO \ 4:3 \ 16:9 \ JUST \

S-VIDEO

ZOOM

 

 

NTSC signal

 

 

 

4:3 \ 16:9

 

4:3 \ 16:9

PC (RGB)

VGA or SVGA signals

Not switchable

 

 

WIDE480/600/720/768/768-2/800

 

/900 signals

 

 

 

4:3 \ 16:9

 

16:9 \ H - FIT \ V - FIT \

 

ZOOM

 

1 125

(1 080)/50i,

 

1 125

(1 080)/60i,

HDMI

1 125

(1 080)/50p,

1 125

(1 080)/60p,

 

 

1 125

(1 080)/24p, 750 (720)/50p

 

and 750 (720)/60p signals

 

4:3 \ 16:9 \ JUST \ ZOOM

 

525p (480p) and 625p (576p)

 

signals

 

4:3 \ 16:9 \ 14:9 \ JUST \

 

ZOOM1 \ ZOOM2

 

625i (576i), 625p (576p)

 

AUTO \ 4:3 \ 16:9 \ JUST \

 

ZOOM

COMPONENT

525i (480i), 525p (480p)

16:9 \ H - FIT \ V - FIT

(YPBPR)

1 125

(1 080)/50i,

 

 

1 125

(1 080)/60i,

 

1 125

(1 080)/50p,

 

1 125

(1 080)/60p,

 

1 125

(1 080)/24p, 750 (720)/50p,

 

750 (720)/60p signals

 

 

 

WSS

WSS (Wide Screen Signalling) detects if a

PAL/625p (576p)/625i (576i) signal is input and that signal has an identification signal, and switch the aspect ratio to required setting automatically. You can switch the system off manually.

OVER SCAN

If the 4 edges of an image is partly dropped, you can use this function to adjust and project it properly.

Shrink Enlarge

Setting range: 0 to +10

OVER SCAN is not available with PC signals.

KEYSTONE

If the projector is aligned non-perpendicularly to the screen, or if the projection screen has an angled surface, you can vertically correct keystone.

Image

Operation

 

 

 

 

 

 

Setting range: -32 to 32

NOTE:

You can correct the distortion ± 30 degrees from the vertical plane. For a better quality image, installing the projector with a minimum of distortion is recommended.

Some distortion may be retained for Lens shift adjustment.

The distortion of the Main menu screen is not correctable.

The result of the keystone correction will affect the aspect ratio and the size of the image.

AUTO SETUP

You can adjust V - POSITION, H - POSITION, DOT CLOCK and CLOCK PHASE automatically when connecting via PC. Press ENTER to adjust these at the same time.

36 - ENGLISH

Image 36
Contents Operating Instructions Important Safety Notice PT-AE1000UImportant Safety Notice PanasonicContents Settings MaintenanceAppendix Precautions with regard to safety Do not look into the lens while the projector is being used Always disconnect all cables before moving the projectorDo not place any heavy objects on top of the projector Use only the specified batteriesDo not put your weight on this projector Do not mix old and new batteriesAccessories Remote controlBefore use Order to get the best picture quality Do not touch the surfaces of the lens with your bare handsScreen LampRemote control About Your ProjectorFront, back and top view Projector Top and front viewBack and bottom view SerialHdmi Component 2 Setting up Calculation methods for screen dimensionsScreen size and throw distance Front leg adjuster and throwing angle Projection methodAdjusting the Lens shift dials Lens shift and positioningHorizontal shift Vertical shiftAdjustable projection range Projector location rangeAfter fixing the screen position Connecting with COMPONENT/VIDEO/S-VIDEO Connecting with HDMI/PCConnections Before connection to the projectorSwitching the projector on/off Power cordPower indicator ConnectingSwitching on the projector Switching off the projectorPower indicator Selecting the input signal Projecting an imagePositioning the image Remote control operation Resetting to the factory default settingsOperating range Turning on the button backlightSwitching the input signal Switching the aspect ratioAdjusting the waveform of the input signal Adjusting the waveformAdjusting in Picture menu Adjusting in Advanced menuAdjusting the focus and zoom Switching the picture modeAdjusting the image Switching off the projector automaticallySetting your own color profile Adjusting the selected colorCreate a new profile ColorSaving a log setting as a profile Loading saved profilesManaging stored logs Operating procedure Menu NavigationNavigating through the Menu Displaying the Main menuSub-menu items Default setting See Position Menu on Sub-menu items Default settingMain menu and Sub-menu 169*5Language Picture Menu Dynamic Iris Waveform MonitorAdvanced Menu NR Noise ReductionSignal Mode Memory SaveMemory Load Secam NtscClock Phase Position MenuDOT Clock PositionComponent signals AspectAspect ratio options and projection example Auto Setup Aspect ratio depend on signalsWSS Over ScanLens Control Menu ZOOM/FOCUSOption Menu Installation Lamp PowerSleep AltitudeTemp and Lamp Indicators Lamp indicator Temp indicatorLamp indicator Controlling alertsCare and Replacement Before cleaningCleaning your projector When to replace the Lamp unit Before replacing the Lamp unitReplacing the lamp unit Opening the top coverResetting the Lamp Runtime Removing and replacing the lamp unitAttaching the top cover Lamp unit fixing screws Lamp unit lock Press hereTroubleshooting List of compatible signals Resolution Frequency Quality*2 Format Dots*1 MHz KHzTechnical Information Display Scanning Dot clock Frequency PicturePin assignments and signal names Communication settingsSerial terminal Connection Sub 9 pin maleControl commands Inquiry commands Cable specificationsBasic format ProjectorMenu structure Picture Menu 31 HPosition Menu 34 H Lens Control Menu 37 HSpecifications NTSC/NTSC 4.43/PAL/PAL-M/PAL-N/SECAMHDMI1 IN/HDMI2 Dimensions Trademark acknowledgements Index DOT Clock Dynamic IrisIndex