Removing and replacing the lamp unit

1.Use a Phillips screw driver to loosen the 3 lamp unit fixing screws until the screws turn freely.

2.Hold the handle of the lamp unit and release the lamp unit lock.

3.Pull out the lamp unit gently from the projector.

4.Replace the new lamp unit while making sure that the direction of insertion is correct.

Press the top of the lamp unit and make sure the unit is installed securely.

5.Tighten the lamp unit fixing screws securely with a Phillips screwdriver.

Care and Replacement

Lamp unit fixing screws

Lamp unit lock

Press here

Press here

Attaching the top cover

1.Attach the hinge parts of the top cover to the projector and press slightly until it clicks.

2.Hook the tabs of the top cover to the projector and lift down slowly.

3. Press the back corner of the top cover gently until it clicks.

NOTE:

Be sure to install the lamp unit and the top cover of the projector securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

Grip the handle and keep the lamp unit paralleled when you remove the Lamp unit. Some parts of the lamp unit are sharpened and may cause injury.

Do not switch the power on while the top cover is opened.

When the projector is mounted in the ceiling, keep the lamp unit paralleled and remove.

Resetting the LAMP RUNTIME

If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure should thus be completed within 10 minutes. See “LAMP RUNTIME” on page 39.

Maintenance

1.Connect the Power cord to the projector and a wall socket, and switch the MAIN POWER on.

2.Switch the POWER button.

3.Press the MENU button to display the menu.

4.Press F G to select OPTION and press ENTER.

5.Press F G to select LAMP RUNTIME.

6.Press and hold the ENTER button for approximately 3 seconds.

7.The confirmation screen will be displayed and select OK.

8.Switch off the POWER to reset the duration of the

LAMP RUNTIME.

9.Confirm the duration of time in LAMP RUNTIME is reset to “0”.

ENGLISH - 43

Image 43
Contents Operating Instructions PT-AE1000U Important Safety NoticePanasonic Important Safety NoticeContents Maintenance SettingsAppendix Precautions with regard to safety Use only the specified batteries Do not look into the lens while the projector is being usedAlways disconnect all cables before moving the projector Do not place any heavy objects on top of the projectorDo not mix old and new batteries Do not put your weight on this projectorRemote control AccessoriesBefore use Lamp Order to get the best picture qualityDo not touch the surfaces of the lens with your bare hands ScreenAbout Your Projector Remote controlFront, back and top view Top and front view ProjectorSerial Back and bottom viewHdmi Component 2 Calculation methods for screen dimensions Setting upScreen size and throw distance Projection method Front leg adjuster and throwing angleVertical shift Adjusting the Lens shift dialsLens shift and positioning Horizontal shiftProjector location range Adjustable projection rangeAfter fixing the screen position Before connection to the projector Connecting with COMPONENT/VIDEO/S-VIDEOConnecting with HDMI/PC ConnectionsConnecting Switching the projector on/offPower cord Power indicatorSwitching off the projector Switching on the projectorPower indicator Projecting an image Selecting the input signalPositioning the image Turning on the button backlight Remote control operationResetting to the factory default settings Operating rangeSwitching the aspect ratio Switching the input signalAdjusting in Advanced menu Adjusting the waveform of the input signalAdjusting the waveform Adjusting in Picture menuSwitching off the projector automatically Adjusting the focus and zoomSwitching the picture mode Adjusting the imageColor Setting your own color profileAdjusting the selected color Create a new profileLoading saved profiles Saving a log setting as a profileManaging stored logs Displaying the Main menu Operating procedureMenu Navigation Navigating through the Menu169*5 Sub-menu items Default settingSee Position Menu on Sub-menu items Default setting Main menu and Sub-menuLanguage Picture Menu NR Noise Reduction Dynamic IrisWaveform Monitor Advanced MenuSecam Ntsc Signal ModeMemory Save Memory LoadPosition Clock PhasePosition Menu DOT ClockAspect Component signalsAspect ratio options and projection example Over Scan Auto SetupAspect ratio depend on signals WSSZOOM/FOCUS Lens Control MenuOption Menu Altitude InstallationLamp Power SleepControlling alerts Temp and Lamp IndicatorsLamp indicator Temp indicator Lamp indicatorBefore cleaning Care and ReplacementCleaning your projector Opening the top cover When to replace the Lamp unitBefore replacing the Lamp unit Replacing the lamp unitLamp unit fixing screws Lamp unit lock Press here Resetting the Lamp RuntimeRemoving and replacing the lamp unit Attaching the top coverTroubleshooting Display Scanning Dot clock Frequency Picture List of compatible signalsResolution Frequency Quality*2 Format Dots*1 MHz KHz Technical InformationConnection Sub 9 pin male Pin assignments and signal namesCommunication settings Serial terminalControl commands Projector Inquiry commandsCable specifications Basic formatLens Control Menu 37 H Menu structurePicture Menu 31 H Position Menu 34 HNTSC/NTSC 4.43/PAL/PAL-M/PAL-N/SECAM SpecificationsHDMI1 IN/HDMI2 Dimensions Trademark acknowledgements DOT Clock Dynamic Iris IndexIndex