2.41. DYNAMIC IRIS (MANUAL IRIS)

Hexadecimal

02h

41h

44h

5Ah

5Ah

3Bh

4Fh

41h

49h

3Ah

Character

 

A

D

Z

Z

;

O

A

I

:

Hexadecimal

4Dh

*1

*3

03h

 

 

 

 

 

 

Character

M

*2

*4

 

 

 

 

 

 

 

Parameters (*1, *2, *3, *4)

 

OFF

 

1

 

2

 

 

3

Hexadecimal

30h

 

30h

30h

 

31h

30h

 

32h

30h

 

33h

Character

0

 

0

0

 

1

0

 

2

0

 

3

 

60

 

61

 

62

 

 

63

Hexadecimal

36h

30h

36h

31h

36h

32h

36h

 

33h

Character

6

 

0

6

 

1

6

 

2

6

3

Response (Callback)

In the period when the command can be accepted

 

Hexadecimal

 

02h

 

4Fh

 

41h

 

49h

3Ah

 

4Dh

 

*1

 

03h

 

Character

 

 

 

 

O

 

A

 

 

I

:

 

 

M

 

*2

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STNDBY

 

NO SIGNAL

 

SHUTTER

 

TEST PATTERN

 

REMOTE2

 

 

 

No

 

No

 

 

Yes

 

Yes

 

 

Yes

 

 

Yes

 

 

2.42. DYNAMIC IRIS (DYNAMIC GAMMA)

Hexadecimal

02h

41h

44h

5Ah

5Ah

3Bh

4Fh

41h

49h

3Ah

Character

 

A

D

Z

Z

;

O

A

I

:

Hexadecimal

44h

*1

03h

 

 

 

 

 

 

 

Character

D

*2

 

 

 

 

 

 

 

 

Parameters (*1, *2)

 

OFF

1

2

3

Hexadecimal

30h

31h

32h

33h

Character

0

1

2

3

Response (Callback)

In the period when the command can be accepted

 

Hexadecimal

 

02h

 

4Fh

 

41h

 

49h

3Ah

 

44h

 

*1

 

03h

 

Character

 

 

 

 

O

 

A

 

 

I

:

 

 

D

 

*2

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STNDBY

 

NO SIGNAL

 

SHUTTER

 

TEST PATTERN

 

REMOTE2

 

 

 

No

 

No

 

 

Yes

 

Yes

 

 

Yes

 

 

Yes

 

 

2.43. TV-SYSTEM

Hexadecimal

02h

41h

44h

5Ah

5Ah

3Bh

56h

53h

47h

3Ah

Character

 

A

D

Z

Z

;

V

S

G

:

Hexadecimal

*1

*3

*5

03h

 

 

 

 

 

 

Character

*2

*4

*6

 

 

 

 

 

 

 

Parameters (*1, *2, *3, *4, *5, *6)

 

 

AUTO 1

 

 

AUTO 2

 

 

NTSC

 

Hexadecimal

41h

54h

 

31h

41h

54h

32h

4Eh

54h

53h

Character

A

T

 

1

A

T

2

N

T

S

 

 

NTSC4.43

 

 

 

PAL

 

 

PAL-M

 

Hexadecimal

4Eh

34h

 

34h

50h

41h

4Ch

50h

41h

4Dh

Character

N

4

 

4

P

A

L

P

A

M

 

 

PAL-N

 

 

 

SECAM

 

 

PAL60

 

Hexadecimal

50h

41h

4Eh

53h

45h

43h

50h

36h

30h

Character

P

A

N

S

E

C

P

6

0

Response (Callback)

In the period when the command can be accepted

 

Hexadecimal

 

02h

 

56h

 

53h

47h

3Ah

 

*1

 

*3

 

*5

03h

 

Character

 

 

 

 

V

 

S

G

:

 

*2

 

*4

 

*6

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STNDBY

 

NO SIGNAL

 

SHUTTER

TEST PATTERN

 

 

REMOTE2

 

 

 

 

No

 

No

 

 

Yes

 

Yes

 

 

Yes

 

 

 

Yes

 

 

 

16/62

Image 16
Contents Panasonic Projector RS-232C Control Specifications Basic control command with parameters ID of the basic control commandSTX ETXCase of the parameter error Hexadecimal 02h Auto Setup ShutterInput Change  Parameters *1, *2, *3, *4, *5, *6Test Pattern  Parameters *1, *2, *3, *4Menu key Enter keyUp  key Down  keyDefault key Right  keyFUNC1 key System SelectorLamp Select InstallationSUB Memory Change SUB Memory Change Enhanced  ParametersSUB Memory Store SUB Memory DeletePicture Mode ColorTint 10/62Color Temp White Balance LOW RWhite Balance LOW G  Parameters*1,*2,*3,*4,*5,*6White Balance LOW B White Balance High RWhite Balance High G 12/62 White Balance High B Contrast Brightness 13/62Noise Reduction Sharpness14/62 Dynamic Iris Auto Iris Dynamic Iris15/62 Dynamic Iris Manual Iris Dynamic Iris Dynamic GammaTV-SYSTEM 16/62Shift H  Parameters *1, *2, *3, *4, *5, *6, *7, *8Shift 17/62Aspect 18/62Clock Phase Zoom HZoom 19/62Input Resolution Display Dots Input Resolution Total Dots20/62 Input Resolution Total Lines Input Resolution Display LinesClamp Position 21/62Keystone KEYSTONE2Linearity 22/62Blanking Upper Display Language23/62 Blanking Right Blanking Lower24/62 Blanking Left DVI EdidAUX DVI Edid 25/62P Main Windowsize Interlocked P Main Window26/62 P Main Windowsize  Parameters*1, *2, *3, *4, *5, *6P Main Windowsize H P Main Windowsize HVP Main Windowposition H P Main Windowposition28/62 P SUB Window P SUB Windowsize InterlockedP SUB Windowsize 29/62P SUB Windowsize HV P SUB Windowsize H30/62 P SUB Windowposition H P SUB Windowposition31/62 P Frame Lock P TypeSet Date 32/62Query Power Set TimeQuery Shutter 33/62Query Input Change Query Test PatternQuery on Screen 34/62Query Picture Mode Query ColorQuery Tint 35/62Query Color Temp Query White Balance LOW RQuery White Balance LOW G 36/62Query White Balance High G Query White Balance High R37/62 Query White Balance High B Query ContrastQuery Brightness 38/62Query Sharpness Query Noise Reduction Parameters*1,*2 Query Dynamic Iris Parameters *3, *4 Parameters *5, *6, *7, *8Query TV-SYSTEM 40/62Query Shift Query Shift H41/62 Query Aspect 42/62Query Clock Phase Query Zoom HQuery Zoom 43/62Query Input Resolution Total Dots Query Input Resolution Display DotsQuery Input Resolution Total Lines 44/62Query Input Resolution Display Lines Query Clamp PositionQuery Keystone 45/62Query KEYSTONE2 Query LinearityQuery Display Language 46/62Query Blanking Lower Query Blanking Upper47/62 Query Installation Query Blanking RightQuery Blanking Left 48/62Query Projector Runtime  Parameters *1, *2, *3, *4, *5, *6, *7, *8, *9, *10Query Lamp Runtime Query Lamp SelectQuery Lamp Status Query VPS SystemQuery Temp 50/62Query Altitude Query FUNC1Query Usage Condition of Sub Memory Query DVI EdidQuery AUX DVI Edid Query P in PQuery P in P Main Window 52/62Query P in P Main Windowsize Parameters *5, *6, *7, *8, *9, *10 Parameters *11, *12, *13, *14, *15, *16  Parameters *17, *18, *19, *20, *21, *22Query P in P Main Windowposition  Parameters*9,*10, *11, *12, *13, *14, *15, *16Query P in P SUB Window 54/62 Parameters *5, *6, *7, *8, *9, *10 Query P in P SUB Windowsize55/62 Query P in P SUB Windowposition  Parameters *9, *10, *11, *12, *13, *14, *15, *16Query P in P Frame Lock 56/62Query P in P Type Query DateParameters Query TimeExtended Control Command Query Model Series NameQuery Lamp on Status 58/62ID of the extended control command Lens Control Parameters *2  Parameters *3 Parameters *2-*17 Self Check Information60/62 61/62 OUT62/62