Panasonic PT-DW10000  Parameters *3, *4, Parameters *5, *6, *7, *8, Query TV-SYSTEM, 40/62

Page 40

2.104. Query DYNAMIC IRIS

Hexadecimal

02h

41h

44h

5Ah

5Ah

3Bh

51h

41h

49h

3Ah

*1

03h

Character

 

A

D

Z

Z

;

Q

A

I

:

*2

 

Parameters (*1, *2)

 

AUTO IRIS

MANUAL IRIS

DYNAMIC-GAMMA

Hexadecimal

41h

4Dh

44h

Character

A

M

D

Response (Callback)

In the period when the command can be accepted

When AUTO IRIS or DYNAMIC-GAMMA is specified for the parameter (*1, *2)

 

Hexadecimal

02h

 

*3

 

03h

 

 

 

 

 

 

 

Character

 

 

*4

 

 

 

 

 

 

 

 

 

When MANUAL IRIS is specified for the parameter (*1, *2)

 

 

Hexadecimal

02h

 

*5

 

*7

 

 

03h

 

 

 

 

Character

 

 

*6

 

*8

 

 

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY STNDBY

NO SIGNAL

SHUTTER

TEST PATTERN

REMOTE2

 

Yes

No

 

Yes

 

Yes

 

Yes

Yes

Parameters (*3, *4,)

 

 

 

 

OFF

 

 

 

1

 

 

 

2

 

 

 

3

 

 

 

 

 

Hexadecimal

 

30h

 

 

 

31h

 

 

 

32h

 

 

33h

 

 

 

 

 

Character

0

 

 

 

1

 

 

 

2

 

 

 

3

 

 

 



Parameters (*5, *6, *7, *8,)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

1

 

 

 

2

 

 

 

3

 

 

 

 

 

Hexadecimal

 

30h

 

30h

30h

 

 

31h

 

30h

 

 

32h

30h

 

 

33h

 

 

 

Character

0

 

0

 

0

 

 

1

 

0

 

 

2

0

 

 

3

 

 

 

 

60

 

 

 

61

 

 

 

62

 

 

63

 

 

 

 

 

Hexadecimal

 

36h

 

30h

36h

 

 

31h

 

36h

 

 

32h

36h

 

 

33h

 

 

 

Character

6

 

0

 

6

 

 

1

 

6

 

 

2

6

 

 

3

 

2.105. Query TV-SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hexadecimal

 

02h

 

41h

 

44h

5Ah

 

5Ah

3Bh

 

51h

53h

47h

 

03h

 

 

Character

 

 

 

A

D

Z

 

Z

;

 

 

Q

S

 

G

 

 

 

Response (Callback)

In the period when the command can be accepted

 

Hexadecimal

 

02h

*1

 

*3

 

*5

 

03h

 

 

 

Character

 

 

*2

 

*4

 

*6

 

 

 

 

 

Acceptability

 

 

 

 

 

 

 

 

 

 

 

 

SECURITY

STNDBY

NO SIGNAL

SHUTTER

TEST PATTERN

REMOTE2

 

Yes

 

No

Yes

 

Yes

 

Yes

Yes

Parameters (*1, *2, *3, *4, *5, *6)

 

 

AUTO 1

 

 

AUTO 2

 

 

NTSC

 

Hexadecimal

41h

54h

 

31h

41h

54h

32h

4Eh

54h

53h

Character

A

T

 

1

A

T

2

N

T

S

 

 

NTSC4.43

 

 

 

PAL

 

 

PAL-M

 

Hexadecimal

4Eh

34h

 

34h

50h

41h

4Ch

50h

41h

4Dh

Character

N

4

 

4

P

A

L

P

A

M

 

 

PAL-N

 

 

 

SECAM

 

 

PAL60

 

Hexadecimal

50h

41h

 

4Eh

53h

45h

43h

50h

36h

30h

Character

P

A

 

N

S

E

C

P

6

0

40/62

Image 40
Contents Panasonic Projector RS-232C Control Specifications Basic control command with parameters ID of the basic control commandSTX ETXCase of the parameter error Hexadecimal 02h Auto Setup ShutterInput Change  Parameters *1, *2, *3, *4, *5, *6Test Pattern  Parameters *1, *2, *3, *4Menu key Enter keyUp  key Down  keyDefault key Right  keyFUNC1 key System SelectorLamp Select InstallationSUB Memory Change SUB Memory Change Enhanced  ParametersSUB Memory Store SUB Memory DeletePicture Mode ColorTint 10/62Color Temp White Balance LOW RWhite Balance LOW G  Parameters*1,*2,*3,*4,*5,*6White Balance LOW B White Balance High RWhite Balance High G 12/62White Balance High B ContrastBrightness 13/62Noise Reduction Sharpness14/62 Dynamic Iris Auto Iris Dynamic Iris15/62 Dynamic Iris Manual Iris Dynamic Iris Dynamic GammaTV-SYSTEM 16/62Shift H  Parameters *1, *2, *3, *4, *5, *6, *7, *8Shift 17/62Aspect 18/62Clock Phase Zoom HZoom 19/62Input Resolution Display Dots Input Resolution Total Dots20/62 Input Resolution Total Lines Input Resolution Display LinesClamp Position 21/62Keystone KEYSTONE2Linearity 22/62Blanking Upper Display Language23/62 Blanking Right Blanking Lower24/62 Blanking Left DVI EdidAUX DVI Edid 25/62P Main Windowsize Interlocked P Main Window26/62 P Main Windowsize  Parameters*1, *2, *3, *4, *5, *6P Main Windowsize H P Main Windowsize HVP Main Windowposition H P Main Windowposition28/62 P SUB Window P SUB Windowsize InterlockedP SUB Windowsize 29/62P SUB Windowsize HV P SUB Windowsize H30/62 P SUB Windowposition H P SUB Windowposition31/62 P Frame Lock P TypeSet Date 32/62Query Power Set TimeQuery Shutter 33/62Query Input Change Query Test PatternQuery on Screen 34/62Query Picture Mode Query ColorQuery Tint 35/62Query Color Temp Query White Balance LOW RQuery White Balance LOW G 36/62 Query White Balance High G Query White Balance High R 37/62 Query White Balance High B Query ContrastQuery Brightness 38/62Query Sharpness Query Noise Reduction Parameters*1,*2 Query Dynamic Iris Parameters *3, *4 Parameters *5, *6, *7, *8Query TV-SYSTEM 40/62Query Shift Query Shift H41/62 Query Aspect 42/62Query Clock Phase Query Zoom HQuery Zoom 43/62Query Input Resolution Total Dots Query Input Resolution Display DotsQuery Input Resolution Total Lines 44/62Query Input Resolution Display Lines Query Clamp PositionQuery Keystone 45/62Query KEYSTONE2 Query LinearityQuery Display Language 46/62Query Blanking Lower Query Blanking Upper47/62 Query Installation Query Blanking RightQuery Blanking Left 48/62Query Projector Runtime  Parameters *1, *2, *3, *4, *5, *6, *7, *8, *9, *10Query Lamp Runtime Query Lamp SelectQuery Lamp Status Query VPS SystemQuery Temp 50/62Query Altitude Query FUNC1Query Usage Condition of Sub Memory Query DVI EdidQuery AUX DVI Edid Query P in PQuery P in P Main Window 52/62Query P in P Main Windowsize Parameters *5, *6, *7, *8, *9, *10 Parameters *11, *12, *13, *14, *15, *16  Parameters *17, *18, *19, *20, *21, *22Query P in P Main Windowposition  Parameters*9,*10, *11, *12, *13, *14, *15, *16Query P in P SUB Window 54/62 Parameters *5, *6, *7, *8, *9, *10 Query P in P SUB Windowsize55/62 Query P in P SUB Windowposition  Parameters *9, *10, *11, *12, *13, *14, *15, *16Query P in P Frame Lock 56/62Query P in P Type Query DateParameters Query TimeExtended Control Command Query Model Series NameQuery Lamp on Status 58/62ID of the extended control command Lens Control Parameters *2  Parameters *3 Parameters *2-*17 Self Check Information60/62 61/62 OUT62/62