Page 45
2.115. Query INPUT RESOLUTION — DISPLAY LINES
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 44h | 4Ch | 03h |
Character | | A | D | Z | Z | ; | Q | D | L | |
Response (Callback)
In the period when the command can be accepted
| Hexadecimal | | 02h | | *1 | *3 | | *5 | | *7 | 03h | | |
| Character | | | | *2 | *4 | | *6 | | *8 | | | |
| Acceptability | | | | | | | | | | | | |
| SECURITY STNDBY | NO SIGNAL | SHUTTER | | TEST PATTERN | REMOTE2 |
| Yes | No | | No | Yes | | | Yes | | | Yes |
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
| | 200 | | | | | 201 | |
Hexadecimal | 30h | 32h | | 30h | 30h | 30h | 32h | | 30h | 31h |
Character | 0 | 2 | | 0 | 0 | 0 | 2 | | 0 | 1 |
| | 1199 | | | | | 1200 | |
Hexadecimal | 31h | 31h | 39h | 39h | 31h | 32h | | 30h | 30h |
Character | 1 | 1 | | 9 | 8 | 1 | 2 | 0 | 0 |
Note:
•This command is acceptable only when RGB1 or RGB2 is selected and RGB signals are input. In other cases, ER401 is returned.
2.116. Query CLAMP POSITION
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 4Ch | 54h | 03h |
Character | | A | D | Z | Z | ; | Q | L | T | |
Response (Callback)
In the period when the command can be accepted
| Hexadecimal | | 02h | *1 | | *3 | | *5 | | 03h | | |
| Character | | | *2 | | *4 | | *6 | | | | |
| Acceptability | | | | | | | | | | | |
| SECURITY | STNDBY | NO SIGNAL | SHUTTER | TEST PATTERN | REMOTE2 |
| Yes | | No | No | | Yes | | Yes | Yes |
Parameters (*1, *2, *3, *4, *5, *6)
| | 0 | | | 1 | | | 2 | |
Hexadecimal | 30h | 30h | 30h | 30h | 30h | 31h | 30h | 30h | 32h |
Character | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 2 |
| | 253 | | | 254 | | | 255 | |
Hexadecimal | 32h | 35h | 33h | 32h | 35h | 34h | 32h | 35h | 35h |
Character | 2 | 5 | 3 | 2 | 5 | 4 | 2 | 5 | 5 |
Note:
• This command is acceptable only when RGB1 or RGB2 is selected. In other cases, ER401 is returned.
2.117. Query KEYSTONE
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 4Bh | 53h | 03h |
Character | | A | D | Z | Z | ; | Q | K | S | |
Response (Callback)
In the period when the command can be accepted
| Hexadecimal | | 02h | | *1 | *3 | | *5 | | *7 | 03h | |
| Character | | | | *2 | *4 | | *6 | | *8 | | |
| Acceptability | | | | | | | | | | | |
| SECURITY STNDBY | NO SIGNAL | SHUTTER | | TEST PATTERN REMOTE2 |
| Yes | No | | Yes | Yes | | | Yes | Yes |
Parameters (*1, *2, *3, *4, *5, *6, *7, *8)
| | 127 | | | 126 | | | | 125 | |
Hexadecimal | 2Dh | 31h | 32h | 37h | 2Dh | | 31h | | 32h | | 36h | 2Dh | 31h | 32h | 35h |
Character | | 1 | 2 | 7 | | 1 | 2 | 6 | | 1 | 2 | 5 |
| | +125 | | | +126 | | | | +127 | |
Hexadecimal | 2Bh | 31h | 32h | 35h | 2Bh | | 31h | | 32h | | 36h | 2Bh | 31h | 32h | 37h |
Character | + | 1 | 2 | 5 | + | | 1 | | 2 | | 6 | + | 1 | 2 | 7 |
45/62
Contents
Panasonic Projector RS-232C Control Specifications
ID of the basic control command
Basic control command with parameters
STX
ETX
Case of the parameter error Hexadecimal 02h
Shutter
Auto Setup
Parameters *1, *2, *3, *4, *5, *6
Input Change
Test Pattern
Parameters *1, *2, *3, *4
Enter key
Menu key
Up key
Down key
Right key
Default key
FUNC1 key
System Selector
Installation
Lamp Select
SUB Memory Change
Parameters
SUB Memory Change Enhanced
SUB Memory Store
SUB Memory Delete
Color
Picture Mode
Tint
10/62
White Balance LOW R
Color Temp
White Balance LOW G
Parameters*1,*2,*3,*4,*5,*6
White Balance High R
White Balance LOW B
White Balance High G
12/62
Contrast
White Balance High B
Brightness
13/62
Sharpness
Noise Reduction
14/62
Dynamic Iris
Dynamic Iris Auto Iris
15/62
Dynamic Iris Dynamic Gamma
Dynamic Iris Manual Iris
TV-SYSTEM
16/62
Parameters *1, *2, *3, *4, *5, *6, *7, *8
Shift H
Shift
17/62
18/62
Aspect
Zoom H
Clock Phase
Zoom
19/62
Input Resolution Total Dots
Input Resolution Display Dots
20/62
Input Resolution Display Lines
Input Resolution Total Lines
Clamp Position
21/62
KEYSTONE2
Keystone
Linearity
22/62
Display Language
Blanking Upper
23/62
Blanking Lower
Blanking Right
24/62
DVI Edid
Blanking Left
AUX DVI Edid
25/62
P Main Window
P Main Windowsize Interlocked
26/62
Parameters*1, *2, *3, *4, *5, *6
P Main Windowsize
P Main Windowsize H
P Main Windowsize HV
P Main Windowposition
P Main Windowposition H
28/62
P SUB Windowsize Interlocked
P SUB Window
P SUB Windowsize
29/62
P SUB Windowsize H
P SUB Windowsize HV
30/62
P SUB Windowposition
P SUB Windowposition H
31/62
P Type
P Frame Lock
Set Date
32/62
Set Time
Query Power
Query Shutter
33/62
Query Test Pattern
Query Input Change
Query on Screen
34/62
Query Color
Query Picture Mode
Query Tint
35/62
Query White Balance LOW R
Query Color Temp
Query White Balance LOW G
36/62
Query White Balance High R
Query White Balance High G
37/62
Query Contrast
Query White Balance High B
Query Brightness
38/62
Query Noise Reduction
Query Sharpness
Parameters*1,*2
Query Dynamic Iris
Parameters *5, *6, *7, *8
Parameters *3, *4
Query TV-SYSTEM
40/62
Query Shift H
Query Shift
41/62
42/62
Query Aspect
Query Zoom H
Query Clock Phase
Query Zoom
43/62
Query Input Resolution Display Dots
Query Input Resolution Total Dots
Query Input Resolution Total Lines
44/62
Query Clamp Position
Query Input Resolution Display Lines
Query Keystone
45/62
Query Linearity
Query KEYSTONE2
Query Display Language
46/62
Query Blanking Upper
Query Blanking Lower
47/62
Query Blanking Right
Query Installation
Query Blanking Left
48/62
Parameters *1, *2, *3, *4, *5, *6, *7, *8, *9, *10
Query Projector Runtime
Query Lamp Runtime
Query Lamp Select
Query VPS System
Query Lamp Status
Query Temp
50/62
Query FUNC1
Query Altitude
Query Usage Condition of Sub Memory
Query DVI Edid
Query P in P
Query AUX DVI Edid
Query P in P Main Window
52/62
Parameters *5, *6, *7, *8, *9, *10
Query P in P Main Windowsize
Parameters *11, *12, *13, *14, *15, *16
Parameters *17, *18, *19, *20, *21, *22
Parameters*9,*10, *11, *12, *13, *14, *15, *16
Query P in P Main Windowposition
Query P in P SUB Window
54/62
Query P in P SUB Windowsize
Parameters *5, *6, *7, *8, *9, *10
55/62
Parameters *9, *10, *11, *12, *13, *14, *15, *16
Query P in P SUB Windowposition
Query P in P Frame Lock
56/62
Query Date
Query P in P Type
Parameters
Query Time
Query Model Series Name
Extended Control Command
Query Lamp on Status
58/62
Lens Control
ID of the extended control command
Parameters *2
Parameters *3
Self Check Information
Parameters *2-*17
60/62
OUT
61/62
62/62