2.109. Query ZOOM H
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 5Ah | 48h | 03h |
Character |
| A | D | Z | Z | ; | Q | Z | H |
|
Response (Callback)
In the period when the command can be accepted
| Hexadecimal |
| 02h | *1 |
| *3 |
| *5 |
| 03h |
|
|
| Character |
|
| *2 |
| *4 |
| *6 |
|
|
|
|
| Acceptability |
|
|
|
|
|
|
|
|
|
|
|
| SECURITY | STNDBY | NO SIGNAL | SHUTTER | TEST PATTERN | REMOTE2 | ||||||
| Yes |
| No | No |
| Yes |
| No | Yes |
Parameters (*1, *2, *3, *4, *5, *6)
|
| 50 |
|
| 51 |
|
| 52 |
|
Hexadecimal | 30h | 35h | 30h | 30h | 35h | 31h | 30h | 35h | 32h |
Character | 0 | 5 | 0 | 0 | 5 | 1 | 0 | 5 | 2 |
|
| 997 |
|
| 998 |
|
| 999 |
|
Hexadecimal | 39h | 39h | 37h | 39h | 39h | 38h | 39h | 39h | 39h |
Character | 9 | 9 | 7 | 9 | 9 | 8 | 9 | 9 | 9 |
Notes:
•When ASPECT is THROUGH, ER401 is returned.
•Even if INTERLOCKED is ON, the value of ZOOM H is returned.
2.110. Query ZOOM V
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 5Ah | 56h | 03h |
Character |
| A | D | Z | Z | ; | Q | Z | V |
|
Response (Callback)
In the period when the command can be accepted
| Hexadecimal |
| 02h | *1 |
| *3 |
| *5 |
| 03h |
|
|
| Character |
|
| *2 |
| *4 |
| *6 |
|
|
|
|
| Acceptability |
|
|
|
|
|
|
|
|
|
|
|
| SECURITY | STNDBY | NO SIGNAL | SHUTTER | TEST PATTERN | REMOTE2 | ||||||
| Yes |
| No | No |
| Yes |
| No | Yes |
Parameters (*1, *2, *3, *4, *5, *6)
|
| 50 |
|
| 51 |
|
| 52 |
|
Hexadecimal | 30h | 35h | 30h | 30h | 35h | 31h | 30h | 35h | 32h |
Character | 0 | 5 | 0 | 0 | 5 | 1 | 0 | 5 | 2 |
|
| 997 |
|
| 998 |
|
| 999 |
|
Hexadecimal | 39h | 39h | 37h | 39h | 39h | 38h | 39h | 39h | 39h |
Character | 9 | 9 | 7 | 9 | 9 | 8 | 9 | 9 | 9 |
Notes:
•When ASPECT is THROUGH, ER401 is returned.
•Even if INTERLOCKED is ON, the value of ZOOM H is returned.
2.111. Query CLOCK PHASE
Hexadecimal | 02h | 41h | 44h | 5Ah | 5Ah | 3Bh | 51h | 43h | 50h | 03h |
Character |
| A | D | Z | Z | ; | Q | C | P |
|
Response (Callback)
In the period when the command can be accepted |
|
|
|
|
| |||||||
| Hexadecimal |
| 02h | *1 |
| *3 |
| *5 |
| 03h |
|
|
| Character |
|
| *2 |
| *4 |
| *6 |
|
|
|
|
| Acceptability |
|
|
|
|
|
|
|
|
|
|
|
| SECURITY | STNDBY | NO SIGNAL | SHUTTER | TEST PATTERN | REMOTE2 | ||||||
| Yes |
| No | No | Yes |
|
| No | Yes |
Parameters (*1, *2, *3, *4, *5, *6)
|
| 0 |
|
| 1 |
|
| 2 |
|
Hexadecimal | 30h | 30h | 30h | 30h | 30h | 31h | 30h | 30h | 32h |
Character | 0 | 0 | 0 | 0 | 0 | 1 | 0 | 0 | 2 |
|
| 29 |
|
| 30 |
|
| 31 |
|
Hexadecimal | 30h | 32h | 39h | 30h | 33h | 30h | 30h | 33h | 31h |
Character | 0 | 2 | 9 | 0 | 3 | 0 | 0 | 3 | 1 |
Note:
• It is able to accept only when the selected slot is RGB1 or RGB2, and ER401 is returned besides.