Care and Replacement
Replacement procedure
Removing and replacing the lamp unit
1. Use a | 5. Replace the new Lamp unit in correct direction. |
Lamp unit cover fixing screws on the back of the |
|
projector until the screws turn freely, and remove |
|
the Lamp unit cover. |
|
Lamp unit cover |
|
Lamp unit cover fixing screws
2. Use a |
Lamp unit fixing screws. |
6.Press in the Lamp unit until it clicks and make sure the unit is installed securely.
7.Tighten the 2 Lamp unit fixing screws securely with a
3. Hold the handles of the Lamp unit and release the |
lamp unit lock. |
Lamp unit
Press here
4. Pull the used Lamp unit gently from the projector. |
Lamp unit
fixing screws
Handles
fixing screws
8.Attach the Lamp unit cover and tighten the 2 Lamp unit cover fixing screws securely with a
LAMP RUNTIME will be reset to “0” automatically.
Maintenance
Ceiling mount bracket safeguards
The projector and the ceiling mount bracket are designed sufficiently safety though, make sure the safety cable provided with the projector is installed and attached to the bottom of the projector when mounting in the ceiling for safety and security.
NOTE:
•Even if it is guarantee period, the manufacturer is not responsible for any hazard or damage caused by using a ceiling mount bracket which is not purchased from an authorized distributors, or environmental conditions.
•Make sure to use a torque driver and do not use an electrical screwdriver or an impact screwdriver.
•Installation work of the ceiling mount bracket should only be carried by a qualified technician.
•Remove an unused ceiling mount bracket promptly.
Installing the safety cable
1.Install the ceiling mount bracket according to the installation instructions.
2.Loop the security cable around the ceiling mount bracket with less slack.
Lace the cable of the end with a latch through the loop on the other end of the cable.
3.Attach the latch on to the bottom of the projector with a provided screw. Torque: 1.25±0.2 N·m
* Indicated above is