Using the
Table | Factory default configuration settings (continued) | |
|
|
|
Parameter | Factory default | Possible settings |
|
|
|
Filters | Disabled | Disabled, Enabled |
Note: Do not enable both NetBIOS filtering and packet filtering on the same port. When both types of filtering are enabled, only the NetBIOS filtering is active.
Bridge group | 1 | |
Virtual ring number | For ports 1 through 8 on each slot in |
|
(Valid only when source route | hexadecimal format: |
|
bridging is selected.) | Slot 1: 11, 12, 13, 14, 15, 16, 17, 18 |
|
| Slot 2: 21, 22, 23, 24, 25, 26, 27, 28 |
|
| Slot 3: 31, 32, 33, 34, 35, 36, 37, 38 |
|
| Slot 4: 41, 42, 43, 44, 45, 46, 47, 48 |
|
| Slot 5: 51, 52, 53, 54, 55, 56, 57, 58 |
|
| Slot 6: 61, 62, 63, 64, 65, 66, 67, 68 |
|
| Note: The Centillion 50 switch contains only slots 1 through 3. | |
Priority | 128 | |
(Valid only when source route |
|
|
bridging is selected.) |
|
|
Path cost | 16 | |
(Valid only when source route |
|
|
bridging is selected.) |
|
|
ARE hop count | 7 | |
(Valid only when source |
|
|
route bridging is selected.) |
|
|
STE hop count | 7 | |
(Valid only when source route |
|
|
bridging is selected.) |
|
|
SR broadcasting | Auto | Auto, Off, On |
(Valid only when source route |
|
|
bridging is selected.) |
|
|
|
|
|
If the factory default settings are not appropriate for your network, you may be able to use one of the predefined switch configurations that are available in SpeedView. You simply choose one of these without having to configure individual ports.