Installing and Connecting the TokenSpeed Module
•Port 2:
—Act LED lights when software is loaded from flash memory.
—Ins LED lights when software loading is complete and the system begins executing.
•All LEDs turn off when the module has started up successfully.
•Ins LEDs on all ports toggle on and off, until the first port inserts successfully.
On the TokenSpeed module, the following sequence occurs:
•Port 1:
—Act (activity) LED lights during switch memory test.
—Ins (inserted) LED lights during management bus test.
•Port 2:
—Act LED lights while the module waits for software download from the MCP.
•All LEDs turn off when the module has started up successfully.
•Ins LEDs on all ports toggle on and off until the first port inserts successfully.
Configuring the TokenSpeed Module
The TokenSpeed module is shipped preconfigured with the configuration settings listed in Table
Table | Factory default configuration settings |
|
| |
|
|
|
|
|
Parameter |
| Factory default | Possible settings | |
|
|
|
|
|
Switching mode |
| Transparent | Transparent, Source Route, | |
|
|
| Source Route Transparent | |
Spanning Tree Protocol | None | None, IEEE, IBM | ||
State |
| Enabled | Enabled, Disabled | |
Port type |
| Station | Station, Hub, Bay/SNPX RO, | |
|
|
| ||
Ring speed |
| 16 Mb/s | 16, 4, Auto | |
Speed sense |
| Disabled | Disabled, Enabled | |
|
|
|
|
|
|
|
|
|
|
|
|